Direct Analysis in Real Time Coupled to Multiplexed Drift Tube Ion Mobility Spectrometry for Detecting Toxic Chemicals

被引:52
|
作者
Harris, Glenn A. [1 ]
Kwasnik, Mark [1 ]
Fernandez, Facundo M. [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
关键词
DESORPTION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE IONIZATION; MASS-SPECTROMETRY; RESOLVING POWER; WARFARE AGENTS; CHROMATOGRAPHY; FORMULATIONS; AIR;
D O I
10.1021/ac102246h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Current and future chemical threats to homeland security motivate the need for new chemical detection systems to provide border, transportation, and workplace security. We present the first successful coupling of a commercial direct analysis in real time (DART) ion source to a resistive glass monolithic drift tube ion mobility spectrometer (DTIMS) as the basis for a low maintenance, versatile, and robust chemical monitoring system. in situ ionization within the electric field gradient of the instrument enhances sensitivity and provides a safe sampling strategy. The instrument uses nitrogen as both the DART discharge and DTIMS drift gases, allowing for a high electric field to be used for ion separation while keeping cost-of-use low. With the use of a traditional signal averaging acquisition mode, the 95% probability of detection (POD) for analytes sampled from melting point capillary tubes was 11.81% v/v for DMMP, 1.13% v/v for 2-CEES, and 10.61 mM for methamidophos. Sensitivity was improved via a prototype transmission mode geometry interface, resulting in an almost 2 orders of magnitude decrease in the POD level for DMMP (0.28% v/v). As an alternative to transmission mode operation digital multiplexing of the DTIMS ion injection step was also implemented, finding a 3-fold improvement in signal-to-noise ratios for 200 mu s gate injections and a 4.5-fold for 400 mu s gate injections.
引用
收藏
页码:1908 / 1915
页数:8
相关论文
共 50 条
  • [41] Comparison of direct analysis in real-time mass spectrometry, atmospheric solids analysis probe–mass spectrometry, and ion mobility spectrometry for ensuring food safety by rapid screening of poppy seeds
    Sara E. Kern
    Sarah E. Voelker
    Lisa M. Lorenz
    Rachel D. Dicken
    Megan E. Sterling
    Angie S. Mohrhaus
    Valerie M. Toomey
    Analytical and Bioanalytical Chemistry, 2024, 416 : 827 - 837
  • [42] Effect of Sampling Rate and Data Pretreatment for Targeted and Nontargeted Analysis by Means of Liquid Chromatography Coupled to Drift Time Ion Mobility Quadruple Time-of-Flight Mass Spectrometry
    Toetsch, Kristina
    Fjeldsted, John C.
    Stow, Sarah M.
    Schmitz, Oliver J.
    Meckelmann, Sven W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2021, 32 (10) : 2592 - 2603
  • [43] Screening of additives and other chemicals in polyurethanes by direct analysis in real time mass spectrometry (DART-MS)
    Ákos Kuki
    Lajos Nagy
    Tibor Nagy
    Miklós Zsuga
    Sándor Kéki
    Analytical and Bioanalytical Chemistry, 2017, 409 : 6149 - 6162
  • [44] Low Electric Field Drift Tube Ion Mobility Analysis for Atmospheric Pressure Plasma
    Penado K.N.M.
    Catapang A.V.B.
    Wada M.
    Plasma and Fusion Research, 2023, 18
  • [45] Rapid mapping of various chemicals in personal care and healthcare products by direct analysis in real time mass spectrometry
    Kuki, Akos
    Zelei, Georgina
    Nagy, Lajos
    Nagy, Tibor
    Zsuga, Miklos
    Keki, Sandor
    TALANTA, 2019, 192 : 241 - 247
  • [46] Low Electric Field Drift Tube Ion Mobility Analysis for Atmospheric Pressure Plasma
    Nealson, Keith
    Catapang, Allen Vincent B.
    Wada, Motoi
    PLASMA AND FUSION RESEARCH, 2023, 18
  • [47] Screening of additives and other chemicals in polyurethanes by direct analysis in real time mass spectrometry (DART-MS)
    Kuki, Akos
    Nagy, Lajos
    Nagy, Tibor
    Zsuga, Miklos
    Keki, Sandor
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (26) : 6149 - 6162
  • [48] Deciphering drift time measurements from travelling wave ion mobility spectrometry-mass spectrometry studies
    Smith, David P.
    Knapman, Tom W.
    Campuzano, Iain
    Malham, Richard W.
    Berryman, Joshua T.
    Radford, Sheena E.
    Ashcroft, Atison E.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (02) : 113 - 130
  • [49] Use of Ultraviolet Photodissociation Coupled with Ion Mobility Mass Spectrometry To Determine Structure and Sequence from Drift Time Selected Peptides and Proteins
    Theisen, Alina
    Yan, Bin
    Brown, Jeffery M.
    Morris, Michael
    Bellina, Bruno
    Barran, Perdita E.
    ANALYTICAL CHEMISTRY, 2016, 88 (20) : 9964 - 9971
  • [50] Fundamental study of ion trapping and multiplexing using drift tube-ion mobility time-of-flight mass spectrometry for non-targeted metabolomics
    Tim J. Causon
    Le Si-Hung
    Kenneth Newton
    Ruwan T. Kurulugama
    John Fjeldsted
    Stephan Hann
    Analytical and Bioanalytical Chemistry, 2019, 411 : 6265 - 6274