Direct Analysis in Real Time Coupled to Multiplexed Drift Tube Ion Mobility Spectrometry for Detecting Toxic Chemicals

被引:52
|
作者
Harris, Glenn A. [1 ]
Kwasnik, Mark [1 ]
Fernandez, Facundo M. [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
关键词
DESORPTION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE IONIZATION; MASS-SPECTROMETRY; RESOLVING POWER; WARFARE AGENTS; CHROMATOGRAPHY; FORMULATIONS; AIR;
D O I
10.1021/ac102246h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Current and future chemical threats to homeland security motivate the need for new chemical detection systems to provide border, transportation, and workplace security. We present the first successful coupling of a commercial direct analysis in real time (DART) ion source to a resistive glass monolithic drift tube ion mobility spectrometer (DTIMS) as the basis for a low maintenance, versatile, and robust chemical monitoring system. in situ ionization within the electric field gradient of the instrument enhances sensitivity and provides a safe sampling strategy. The instrument uses nitrogen as both the DART discharge and DTIMS drift gases, allowing for a high electric field to be used for ion separation while keeping cost-of-use low. With the use of a traditional signal averaging acquisition mode, the 95% probability of detection (POD) for analytes sampled from melting point capillary tubes was 11.81% v/v for DMMP, 1.13% v/v for 2-CEES, and 10.61 mM for methamidophos. Sensitivity was improved via a prototype transmission mode geometry interface, resulting in an almost 2 orders of magnitude decrease in the POD level for DMMP (0.28% v/v). As an alternative to transmission mode operation digital multiplexing of the DTIMS ion injection step was also implemented, finding a 3-fold improvement in signal-to-noise ratios for 200 mu s gate injections and a 4.5-fold for 400 mu s gate injections.
引用
收藏
页码:1908 / 1915
页数:8
相关论文
共 50 条
  • [21] Structure-drift time relationships in ion mobility mass spectrometry
    Fasciotti, Maira
    Lalli, Priscila M.
    Heerdt, Gabriel
    Steffen, Rafael A.
    Corilo, Yuri E.
    de Sa, Gilberto F.
    Daroda, Romeu J.
    Reis, Francisco de A. M.
    Morgon, Nelson H.
    Pereira, Rosana C. L.
    Eberlin, Marcos N.
    Klitzke, Clecio F.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2013, 16 (02) : 117 - 132
  • [22] Prediction of peptide drift time in ion mobility-mass spectrometry
    Bing Wang
    Steve Valentine
    Sriram Raghuraman
    Manolo Plasencia
    Xiang Zhang
    BMC Bioinformatics, 10
  • [23] Prediction of peptide drift time in ion mobility-mass spectrometry
    Wang, Bing
    Valentine, Steve
    Raghuraman, Sriram
    Plasencia, Manolo
    Zhang, Xiang
    BMC BIOINFORMATICS, 2009, 10
  • [24] Forensic applications of direct analysis in real time (DART) coupled to mass spectrometry
    Almirall, Jose
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [25] Capillary zone electrophoresis coupled to drift tube ion mobility-mass spectrometry for the analysis of native and APTS-labeled N-glycans
    Kevin Jooß
    Sven W. Meckelmann
    Julia Klein
    Oliver J. Schmitz
    Christian Neusüß
    Analytical and Bioanalytical Chemistry, 2019, 411 : 6255 - 6264
  • [26] Capillary zone electrophoresis coupled to drift tube ion mobility-mass spectrometry for the analysis of native and APTS-labeled N-glycans
    Jooss, Kevin
    Meckelmann, Sven W.
    Klein, Julia
    Schmitz, Oliver J.
    Neusuess, Christian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (24) : 6255 - 6264
  • [27] Rapid screening of 35 new psychoactive substances by ion mobility spectrometry (IMS) and direct analysis in real time (DART) coupled to quadrupole time-of-flight mass spectrometry (QTOF-MS)
    Gwak, Seongshin
    Almirall, Jose R.
    DRUG TESTING AND ANALYSIS, 2015, 7 (10) : 884 - 893
  • [28] Investigating the Potential of Drift Tube Ion Mobility for the Analysis of Oxidized Lipids
    da Silva, Katyeny Manuela
    Woelk, Michele
    Nepachalovich, Palina
    Iturrospe, Elias
    Covaci, Adrian
    van Nuijs, Alexander L. N.
    Fedorova, Maria
    ANALYTICAL CHEMISTRY, 2023, 95 (36) : 13566 - 13574
  • [29] Ion mobility spectrometry as detector and sensor for chemical warfare agents and toxic industrial chemicals.
    Eiceman, GA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U145 - U145
  • [30] Detection of Chemical Warfare Agents by Differential Mobility Spectrometry and Drift-time Ion Mobility Spectrometry Hybrid Technology
    Cheng Sha-Sha
    Chen Chuang
    Wang Wei-Guo
    Li Hai-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (09) : 1264 - 1269