Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?

被引:4
|
作者
Cuellar, Derly O., III [1 ]
Velez, Dencel A. Garcia [1 ]
Bledsoe, Gary [2 ]
Watson, J. Tracy [1 ,3 ]
机构
[1] St Louis Univ, Dept Orthopaed Surg, Sch Med, St Louis, MO 63104 USA
[2] St Louis Univ, Pk Sch Engn, St Louis, MO 63103 USA
[3] St Louis Univ, Dept Orthopaed Surg, 3635 Vista Ave,7th Floor Desloge Towers, St Louis, MO 63110 USA
关键词
Femoral neck fracture; Hybrid screw; Hybrid screw fixation; Inverted triangle; Fully threaded; Calcar screw; Length stable; THREADED POSITIONING SCREW; CANNULATED SCREWS; VARUS COLLAPSE; HIP; HEMIARTHROPLASTY; STRENGTH; BURDEN;
D O I
10.1016/j.injury.2021.11.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Traditionally, femoral neck fracture fixation has been performed using three partially threaded cancellous screws. However, fracture collapse with femoral neck shortening, and varus deforma-tion frequently occurs due to posterior medial comminution and lack of calcar support. We hypothesize replacing the inferior neck/calcar screw with a fully threaded, length stable, screw will provide improved biomechanical stability, decrease femoral neck shortening and varus collapse. Methods: Ten matched cadaveric pairs (20 femurs) were randomly assigned to two screw fixation groups. Group 1 (Hybrid) utilized one fully threaded calcar screw & two partially threaded superior screws. Group 2 (PT) utilized all partially threaded screws. Specimens underwent standardized femoral neck os-teotomies, 45 degrees from the horizontal, with 5 mm posteromedial wedge removed to simulate posteromedial comminution. Screws were placed using fluoroscopic guidance. Specimens were biomechanically tested using two loading sequences: 1) Axial load applied up to 700 N, followed by cyclic loading at 2 Hz with loads of 700 to 1,400 N for 10,0 0 0 cycles. 2) All surviving constructs were cyclically loaded to failure in stepwise incremental manner with max load of 4,0 0 0 N. Paired t-tests used to compare stiffness, cycles to failure, and max load to failure (defined as 15 mm load actuator displacement). Results: Construct stiffness was 2848 +/- 344 N/mm in PT vs. 2767 +/- 665 for Hybrid ( P = 0.628). Load to failure demonstrated, hybrid superiority with max cycles to failure (3797 +/- 400 cycles) vs. (2981 +/- 856 cycles in PT) ( p = 0.010), and max load prior to failure (3290 +/- 196 N) vs. (2891 +/- 421 N in PT) ( p = 0.010). No significant difference in bone mineral density was noted in any of the specimens. Conclusions: Our study is the first to assess the biomechanical effects of hybrid fixation for femoral neck fractures. Hybrid screw configuration resulted in significantly stronger constructs, with higher axial load and increased cycles prior to failure. The advantageous mechanical properties demonstrated using a fully threaded inferior calcar screw provides a length stable construct which may prevent the common com-plication of excessive femoral neck shortening, varus collapse and poor functional outcome. (c) 2021 Published by Elsevier Ltd.
引用
收藏
页码:2839 / 2845
页数:7
相关论文
共 50 条
  • [31] Does screw configuration affect subtrochanteric fracture after femoral neck fixation?
    Oakey, Jerome W.
    Stover, Michael D.
    Summers, Hobie D.
    Sartori, Mark
    Havey, Robert M.
    Patwardhan, Avinash G.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (443) : 302 - 306
  • [32] INTERNAL-FIXATION OF FEMORAL-NECK FRACTURES - COMPRESSION SCREW COMPARED WITH NAIL PLATE FIXATION
    SVENNINGSEN, S
    BENUM, P
    NESSE, O
    FURSET, OI
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (04): : 423 - 429
  • [33] Incomplete Screw Thread Engagement of Proximal Fragment: A Possible Failure Risk After Internal Fixation for Femoral Neck Fractures
    Tanaka, Atsuki
    Hiranaka, Takafumi
    Fujishiro, Takaaki
    Koide, Motoki
    Suda, Yoshihito
    Saito, Akira
    Arimoto, Akihiko
    Okamoto, Koji
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [34] INTERNAL FIXATION OF FRACTURES OF THE FEMORAL NECK
    LUOMANEN, RKJ
    PRUDDEN, JF
    AMERICAN JOURNAL OF SURGERY, 1949, 78 (02): : 189 - 198
  • [35] Fixation of fractures of the femoral neck - Reply
    Lykke, N
    Lerud, PJ
    Stromsoe, K
    Thorngren, KG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (02): : 309 - 309
  • [36] Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck
    Filipov, Orlin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (07): : 539 - 543
  • [37] Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck
    Orlin Filipov
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 539 - 543
  • [38] SLIDING SCREW FIXATION FOR PROXIMAL FEMORAL FRACTURES
    WADDELL, JP
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1980, 11 (03) : 607 - 622
  • [39] Should a low starting point be abandoned for cannulated screw fixation of femoral neck fractures?
    Wodarek, Jeremy
    Ostrander, James
    Atkinson, Patrick
    Atkinson, Theresa
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [40] Cannulated Screw Fixation of Femoral Neck Fractures: An Intraoperative Pearl to Avoid a Common Mistake
    Paziuk, Taylor
    Chang, Gerard
    Krieg, James
    TECHNIQUES IN ORTHOPAEDICS, 2021, 36 (04) : 409 - 411