摘要
Background For successful internal fixation for femoral neck fracture, the sliding mechanism of the screw is important because it can induce inter-fragmental compression. The thread should penetrate the fracture line and be located within the proximal fragment. If screw thread engagement is incomplete and a part of the thread remains within the distal fragment, the screw sliding can be disturbed, potentially leading to fixation failure. We hypothesized that screw thread in the fracture is a risk of fixation failure. Methods We studied 133 hips that underwent internal fixation for femoral neck fracture using dual sliding and compression screws (DSCS) with 20 mm threads. The existence of incomplete thread engagement and fixation failure (cut out, perforation, pseudoarthrosis, or femoral neck shortening) were evaluated on anteroposterior hip radiography postoperatively. The distances from the thread end to the fracture line, screw head to the femoral head cortex, and femoral head diameter were measured to analyze their relationships with any incomplete thread engagement and fixation failure. Differences in evaluation data were assessed using Fisher's exact test, Student's t -test, and receiver operating characteristic (ROC) analysis. Results Forty-six cases had at least one screw with incomplete thread engagement, and the other 87 hips had a complete engagement. The failure rate in the group of hips with incomplete thread engagement was significantly higher (7/46, 15.2%) than that in the group of hips with complete thread engagement (3/87, 3.4%) (P = 0.032). Incomplete thread engagement was found in 59 out of 266 screws (22.2%), and a femoral head <= 43.9 mm in diameter was associated with an increased risk of incomplete thread engagement. Most incomplete thread engagement screws (81.4%) had < 5 mm thread length within the distal fragment. Conclusion A partially threaded screw is a significant risk of fixation failure after internal fixation for a femoral neck fracture. The smaller femoral head diameter increases the possibility of incomplete thread engagement. Shortening the thread length by 5 mm may help to avoid incomplete thread engagement.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Analysis of Risk Factors for Femoral Head Necrosis After Internal Fixation in Femoral Neck Fractures
    Wang, Tao
    Sun, Jun-Ying
    Zha, Guo-Chun
    Jiang, Tao
    You, Zhen-Jun
    Yuan, De-Jing
    ORTHOPEDICS, 2014, 37 (12) : E1117 - E1123
  • [2] Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation
    高广升
    李凤辉
    中国组织工程研究, 2001, (24) : 154 - 155
  • [3] Ideal length of thread forms for screws used in screw fixation of nondisplaced femoral neck fractures
    Liu, Christina
    Von Keudell, Arvind
    McTague, Michael
    Rodriguez, Edward K.
    Weaver, Michael J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (03): : 727 - 732
  • [4] Complications after internal screw fixation of nondisplaced femoral neck fractures in elderly patients: A systematic review
    Kim, Seung-Ju
    Park, Hyun-Soo
    Lee, Dong-Woo
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2020, 54 (03) : 337 - 343
  • [5] An algorithm for preoperative prediction of reoperation risk after internal fixation of femoral neck fractures
    Lindequist, S
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1998, 57 (03) : 187 - 199
  • [6] Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?
    Cuellar, Derly O., III
    Velez, Dencel A. Garcia
    Bledsoe, Gary
    Watson, J. Tracy
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (08): : 2839 - 2845
  • [7] Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system
    Wang, Kai
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Feng, Tianxuan
    Liu, Jiajie
    Zheng, Shunze
    Liang, Yaqian
    Ouyang, Jirui
    Cui, Yubo
    Lin, Fengfei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [8] Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system
    Kai Wang
    Dongze Lin
    Peisheng Chen
    Chaohui Lin
    Tianxuan Feng
    Jiajie Liu
    Shunze Zheng
    Yaqian Liang
    Jirui Ouyang
    Yubo Cui
    Fengfei Lin
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Risk factors for implant failure after fixation of proximal femoral fractures with fracture of the lateral femoral wall
    Gao, Zhechen
    Lv, Yang
    Zhou, Fang
    Ji, Hongquan
    Tian, Yun
    Zhang, Zhishan
    Guo, Yan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (02): : 315 - 322
  • [10] THE SLIDING SCREW-PLATE FOR INTERNAL-FIXATION OF FRACTURES OF THE FEMORAL-NECK
    NORDKILD, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 669 - 669