Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?

被引:4
|
作者
Cuellar, Derly O., III [1 ]
Velez, Dencel A. Garcia [1 ]
Bledsoe, Gary [2 ]
Watson, J. Tracy [1 ,3 ]
机构
[1] St Louis Univ, Dept Orthopaed Surg, Sch Med, St Louis, MO 63104 USA
[2] St Louis Univ, Pk Sch Engn, St Louis, MO 63103 USA
[3] St Louis Univ, Dept Orthopaed Surg, 3635 Vista Ave,7th Floor Desloge Towers, St Louis, MO 63110 USA
关键词
Femoral neck fracture; Hybrid screw; Hybrid screw fixation; Inverted triangle; Fully threaded; Calcar screw; Length stable; THREADED POSITIONING SCREW; CANNULATED SCREWS; VARUS COLLAPSE; HIP; HEMIARTHROPLASTY; STRENGTH; BURDEN;
D O I
10.1016/j.injury.2021.11.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Traditionally, femoral neck fracture fixation has been performed using three partially threaded cancellous screws. However, fracture collapse with femoral neck shortening, and varus deforma-tion frequently occurs due to posterior medial comminution and lack of calcar support. We hypothesize replacing the inferior neck/calcar screw with a fully threaded, length stable, screw will provide improved biomechanical stability, decrease femoral neck shortening and varus collapse. Methods: Ten matched cadaveric pairs (20 femurs) were randomly assigned to two screw fixation groups. Group 1 (Hybrid) utilized one fully threaded calcar screw & two partially threaded superior screws. Group 2 (PT) utilized all partially threaded screws. Specimens underwent standardized femoral neck os-teotomies, 45 degrees from the horizontal, with 5 mm posteromedial wedge removed to simulate posteromedial comminution. Screws were placed using fluoroscopic guidance. Specimens were biomechanically tested using two loading sequences: 1) Axial load applied up to 700 N, followed by cyclic loading at 2 Hz with loads of 700 to 1,400 N for 10,0 0 0 cycles. 2) All surviving constructs were cyclically loaded to failure in stepwise incremental manner with max load of 4,0 0 0 N. Paired t-tests used to compare stiffness, cycles to failure, and max load to failure (defined as 15 mm load actuator displacement). Results: Construct stiffness was 2848 +/- 344 N/mm in PT vs. 2767 +/- 665 for Hybrid ( P = 0.628). Load to failure demonstrated, hybrid superiority with max cycles to failure (3797 +/- 400 cycles) vs. (2981 +/- 856 cycles in PT) ( p = 0.010), and max load prior to failure (3290 +/- 196 N) vs. (2891 +/- 421 N in PT) ( p = 0.010). No significant difference in bone mineral density was noted in any of the specimens. Conclusions: Our study is the first to assess the biomechanical effects of hybrid fixation for femoral neck fractures. Hybrid screw configuration resulted in significantly stronger constructs, with higher axial load and increased cycles prior to failure. The advantageous mechanical properties demonstrated using a fully threaded inferior calcar screw provides a length stable construct which may prevent the common com-plication of excessive femoral neck shortening, varus collapse and poor functional outcome. (c) 2021 Published by Elsevier Ltd.
引用
收藏
页码:2839 / 2845
页数:7
相关论文
共 50 条
  • [1] Fixation failure in femoral neck fractures
    Estrada, LS
    Volgas, DA
    Stannard, JP
    Alonso, JE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (399) : 110 - 118
  • [2] SUBCHONDRAL SCREW FIXATION FOR FEMORAL-NECK FRACTURES
    REHNBERG, L
    OLERUD, C
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02): : 178 - 180
  • [3] Cancellous screw fixation for undisplaced femoral neck fractures in the elderly
    Manohara, Ruben
    Liang, Shen
    Huang, Deborah
    Krishna, Lingaraj
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 282 - 286
  • [4] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975
  • [6] Multiple cannulated screw fixation of young femoral neck fractures
    Kim, Joo Yong
    Kong, Gyu Min
    Park, Dae Hyun
    Kim, Dae Yoo
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2015, 31 (06) : 1517 - 1520
  • [7] Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system
    Wang, Kai
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Feng, Tianxuan
    Liu, Jiajie
    Zheng, Shunze
    Liang, Yaqian
    Ouyang, Jirui
    Cui, Yubo
    Lin, Fengfei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [8] Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system
    Kai Wang
    Dongze Lin
    Peisheng Chen
    Chaohui Lin
    Tianxuan Feng
    Jiajie Liu
    Shunze Zheng
    Yaqian Liang
    Jirui Ouyang
    Yubo Cui
    Fengfei Lin
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [10] Modified radiographic views to prevent the anterosuperior and posterosuperior bony violation during screw fixation of femoral neck fractures
    Kumar, Arvind
    Jameel, Javed
    Qureshi, Owais Ahmed
    Kumar, Mukesh
    Haider, Yawar
    Das, Saubhik
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (03): : 459 - 464