Hybrid screw fixation for femoral neck fractures: Does it prevent mechanical failure?

被引:4
|
作者
Cuellar, Derly O., III [1 ]
Velez, Dencel A. Garcia [1 ]
Bledsoe, Gary [2 ]
Watson, J. Tracy [1 ,3 ]
机构
[1] St Louis Univ, Dept Orthopaed Surg, Sch Med, St Louis, MO 63104 USA
[2] St Louis Univ, Pk Sch Engn, St Louis, MO 63103 USA
[3] St Louis Univ, Dept Orthopaed Surg, 3635 Vista Ave,7th Floor Desloge Towers, St Louis, MO 63110 USA
关键词
Femoral neck fracture; Hybrid screw; Hybrid screw fixation; Inverted triangle; Fully threaded; Calcar screw; Length stable; THREADED POSITIONING SCREW; CANNULATED SCREWS; VARUS COLLAPSE; HIP; HEMIARTHROPLASTY; STRENGTH; BURDEN;
D O I
10.1016/j.injury.2021.11.022
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Traditionally, femoral neck fracture fixation has been performed using three partially threaded cancellous screws. However, fracture collapse with femoral neck shortening, and varus deforma-tion frequently occurs due to posterior medial comminution and lack of calcar support. We hypothesize replacing the inferior neck/calcar screw with a fully threaded, length stable, screw will provide improved biomechanical stability, decrease femoral neck shortening and varus collapse. Methods: Ten matched cadaveric pairs (20 femurs) were randomly assigned to two screw fixation groups. Group 1 (Hybrid) utilized one fully threaded calcar screw & two partially threaded superior screws. Group 2 (PT) utilized all partially threaded screws. Specimens underwent standardized femoral neck os-teotomies, 45 degrees from the horizontal, with 5 mm posteromedial wedge removed to simulate posteromedial comminution. Screws were placed using fluoroscopic guidance. Specimens were biomechanically tested using two loading sequences: 1) Axial load applied up to 700 N, followed by cyclic loading at 2 Hz with loads of 700 to 1,400 N for 10,0 0 0 cycles. 2) All surviving constructs were cyclically loaded to failure in stepwise incremental manner with max load of 4,0 0 0 N. Paired t-tests used to compare stiffness, cycles to failure, and max load to failure (defined as 15 mm load actuator displacement). Results: Construct stiffness was 2848 +/- 344 N/mm in PT vs. 2767 +/- 665 for Hybrid ( P = 0.628). Load to failure demonstrated, hybrid superiority with max cycles to failure (3797 +/- 400 cycles) vs. (2981 +/- 856 cycles in PT) ( p = 0.010), and max load prior to failure (3290 +/- 196 N) vs. (2891 +/- 421 N in PT) ( p = 0.010). No significant difference in bone mineral density was noted in any of the specimens. Conclusions: Our study is the first to assess the biomechanical effects of hybrid fixation for femoral neck fractures. Hybrid screw configuration resulted in significantly stronger constructs, with higher axial load and increased cycles prior to failure. The advantageous mechanical properties demonstrated using a fully threaded inferior calcar screw provides a length stable construct which may prevent the common com-plication of excessive femoral neck shortening, varus collapse and poor functional outcome. (c) 2021 Published by Elsevier Ltd.
引用
收藏
页码:2839 / 2845
页数:7
相关论文
共 50 条
  • [41] HIP COMPRESSION SCREW VERSUS NAIL PLATE FIXATION OF FEMORAL-NECK FRACTURES
    BENUM, P
    SVENNINGSEN, S
    NESSE, O
    FURSET, OI
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03): : 387 - 388
  • [42] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Nikolai Ramadanov
    Ionel Toma
    Harald Herkner
    Roman Klein
    Wilhelm Behringer
    Gerrit Matthes
    Scientific Reports, 10
  • [43] Biases in a randomized comparison of three types of screw fixation in displaced femoral neck fractures
    Alho, A
    Austdal, S
    Benterud, JG
    Blikra, G
    Lerud, P
    Raugstad, TS
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 463 - 468
  • [44] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834
  • [45] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Ramadanov, Nikolai
    Toma, Ionel
    Herkner, Harald
    Klein, Roman
    Behringer, Wilhelm
    Matthes, Gerrit
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [46] THE SLIDING SCREW-PLATE FOR INTERNAL-FIXATION OF FRACTURES OF THE FEMORAL-NECK
    NORDKILD, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 669 - 669
  • [47] Treatment of subcapital femoral neck fractures with bioabsorbable or metallic screw fixation -: A preliminary report
    Jukkala-Partio, K
    Partio, EK
    Helevirta, P
    Pohjonen, T
    Törmälä, P
    Rokkanen, P
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2000, 89 (01) : 45 - 52
  • [48] Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation
    Scattergood, S. D.
    Berry, A. L.
    Flannery, O.
    Burdon, A.
    Mitchell, S. R.
    Fletcher, J. W. A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05): : 2565 - 2571
  • [49] Does fully-threaded Headless Compression Screw provide a length-stable fixation in undisplaced femoral neck fractures?
    Chiang, Ming-Hung
    Wang, Chun-Liang
    Fu, Shau-Huai
    Hung, Chih-Chien
    Yang, Rong-Sen
    ASIAN JOURNAL OF SURGERY, 2019, 42 (01) : 320 - 325
  • [50] Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures
    Wang, Chen
    Xu, Gui-Jun
    Han, Zhe
    Jiang, Xuan
    Zhang, Cheng-Bao
    Dong, Qiang
    Ma, Jian-Xiong
    Ma, Xin-Long
    MEDICINE, 2015, 94 (47) : e2139