Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness

被引:20
|
作者
Li, Xuepei [1 ]
Zhou, Yijing [1 ]
Young, Charlotte Aimee [2 ]
Chen, Aiming [3 ]
Jin, Guangming [1 ]
Zheng, Danying [1 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
[2] Nanchang Univ, Affiliated Hosp 3, Dept Ophthalmol, Nanchang, Jiangxi, Peoples R China
[3] Sun Yat Sen Univ, Affiliated Hosp 5, Zhuhai, Peoples R China
基金
中国国家自然科学基金;
关键词
Anterior chamber depth (ACD); corneal thickness; swept source anterior segment optical coherence tomography; Oculus Pentacam; FOURIER-DOMAIN; SCHEIMPFLUG; ULTRASOUND; REPRODUCIBILITY; REPEATABILITY; KERATOCONUS; PARAMETERS; CURVATURE; AGREEMENT; BIOMETRY;
D O I
10.21037/atm-20-187
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Accurate measurements of anterior chamber depth (ACD) and regional corneal thickness are especially important for the diagnosis and treatment of many ocular disease. This study aimed to evaluate the repeatability and reliability of a new swept source anterior segment optical coherence tomography (AS-OCT) and its agreement with Oculus Pentacam for measurements of ACD and corneal thickness (CT). Methods: The central corneal thickness (CCT), superior corneal thickness (SCT), inferior corneal thickness (ICT), nasal corneal thickness (NCT), temporal corneal thickness (TCT) and ACD of the right eye from forty-nine adults aged 18 to 36 years (24.78 +/- 4.36 years old) were measured with Pentacam and AS-OCT (CASIA2). All subjects were measured twice with each device. The repeatability was determined using the coefficient of repeatability (COR), the relative COR and the limits of agreement (LOA). Bland-Altman plot was also used for evaluating the agreement between parameters from the two devices. Results: For the repeatability of CASIA2, the COR of the two measurements of ACD, CCT, SCT, ICT, NCT and TCT was 0.31 mm, 18.58, 25.83, 28.32, 26.71 and 22.09 mu m respectively. There were no statistically significant differences between the CT and ACD measurements by CASIA2 (P>0.05). For measurements with Pentacam and CASIA2, the COR of ACD, CCT, SCT, NCT, ICT and TCT was 0.294 mm, 13.10, 51.57, 48.06, 56.21 and 47.69 mu m respectively. No significant differences were found between the values measured by CAISA2 and Pentacam for CT and ACD (P>0.05). The Bland-Altman analysis also suggested high consistency between measurements obtained by Pentacam and CASIA2. Conclusions: Our results suggest that Pentacam and CASIA2 have good agreement in CT and ACD measurements. The two devices can be considered interchangeable for these parameters' measurements in healthy subjects when monitoring corneal conditions or planning ocular surgery. However, subtle differences between CASIA2 and Pentacam should also be kept in mind for certain specific clinical or research purposes.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Measurement of the Lower Lid Margin Thickness by Anterior Segment Optical Coherence Tomography
    Wang, Da-Hu
    Li, Zhao-Yan
    Liu, Xin-Quan
    [J]. OPHTHALMIC RESEARCH, 2021, 64 (01) : 22 - 27
  • [32] Comparison of anterior segment optical coherence tomography angiography systems for corneal vascularisation
    Ang, Marcus
    Devarajan, Kavya
    Das, Suchandrima
    Stanzel, Tisha
    Tan, Anna
    Girard, Michael
    Schmetterer, Leopold
    Mehta, Jodhbir S.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (07) : 873 - 877
  • [33] Anterior Chamber Depth Measurement in Pseudophakic Eyes: A Comparison of Pentacam and Ultrasound
    Savini, Giacomo
    Olsen, Thomas
    Carbonara, Claudio
    Pazzaglia, Sebastiano
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 341 - 347
  • [34] Comparison of central corneal thickness in corneal edema by ultrasound pachymetry, specular microscopy, and anterior segment optical coherence tomography
    Artuc, Tuncay
    Batur, Muhammed
    [J]. SAUDI JOURNAL OF OPHTHALMOLOGY, 2023, 37 (01) : 1 - 5
  • [35] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885
  • [36] Changes in Corneal Thickness in Congenital Glaucoma, Using Anterior Segment Optical Coherence Tomography
    Lee, Chaeyeon
    Lee, Eun Jung
    Jang, Yoonkyung
    Han, Jong Chul
    Kee, Chang Won
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (08): : 692 - 699
  • [37] Distribution of corneal thickness in the Tunisian population: Study by anterior segment optical coherence tomography
    Ouederni, M.
    Mrad, I
    Sassi, H.
    Bellaaj, M.
    Letaief, H.
    Ayedi, O.
    Cheour, M.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (08): : 874 - 879
  • [38] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    [J]. PLOS ONE, 2021, 16 (06):
  • [39] Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT
    Leung, Christopher Kai-Shun
    Li, Haitao
    Weinreb, Robert Neal
    Liu, Jing
    Cheung, Carol Yim Lui
    Lai, Ricky Yiu Kwong
    Pang, Chi Pui
    Lam, Dennis Shun Chiu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3469 - 3474
  • [40] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    [J]. World Journal of Clinical Cases, 2020, (15) : 3249 - 3258