First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation

被引:89
|
作者
Cavus, Erol [1 ]
Neumann, Tobias [1 ]
Doerges, Volker [1 ]
Moeller, Thora [2 ]
Scharf, Edwin [1 ]
Wagner, Klaus [2 ]
Bein, Berthold [1 ]
Serocki, Goetz [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Klinikum Suedstadt Rostock, Dept Anaesthesiol & Intens Care Med, Rostock, Germany
来源
ANESTHESIA AND ANALGESIA | 2011年 / 112卷 / 02期
关键词
TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; AIRWAY MANAGEMENT; EMERGENCY;
D O I
10.1213/ANE.0b013e31820553fb
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In the present preliminary study we evaluated the C-MAC (R) D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11(5-45) seconds and for successful intubation 17(3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required. (Anesth Analg 2011;112:382-5)
引用
收藏
页码:382 / 385
页数:4
相关论文
共 50 条
  • [31] Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
    Al-Qasmi, Aida
    Al-Alawi, Wafa
    Malik, Azharuddin Mohammed
    Khan, Rashid Manzoor
    Kaul, Naresh
    TRIALS, 2013, 14
  • [32] Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: a randomized, controlled comparison in patients with suspected difficult airways
    Serocki, G.
    Neumann, T.
    Scharf, E.
    Doerges, V.
    Cavus, E.
    MINERVA ANESTESIOLOGICA, 2013, 79 (02) : 121 - 129
  • [33] C-MAC (R) video laryngoscope with D-BLADE (TM) and Frova introducer for awake intubation in a patient with parapharyngeal mass
    Vinayagam, S.
    Dhanger, S.
    Tilak, P.
    Gnanasekar, R.
    SAUDI JOURNAL OF ANAESTHESIA, 2016, 10 (04) : 471 - 473
  • [34] Ease of intubation and hemodynamic responses to nasotracheal intubation using C-MAC videolaryngoscope with D blade: A comparison with use of traditional Macintosh laryngoscope
    Rajan, Sunil
    Kadapamannil, Dilesh
    Barua, Kaushik
    Tosh, Pulak
    Paul, Jerry
    Kumar, Lakshmi
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2018, 34 (03) : 381 - 385
  • [35] Comparing C-MAC videolaryngoscope with direct laryngoscopy for emergency intubation
    Liu, Ya-Yang
    Xue, Fu-Shan
    Li, Hui-Xian
    Yang, Gui-Zhen
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (11) : 785 - 786
  • [36] The performance of C-MAC videostylet versus D-Blade during tracheal intubation in patients with simulated cervical immobilization: A randomized comparative trial
    Anany, Adel Said Mohammed
    Arida, Emad Eldin Abd El Monem
    Oll, Magda Mohamed Abo
    Rida, Hossam El-Din Fouad
    El-Attar, Eman Ahmed Mohamed
    Hozien, Adel Ibrahim
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2024, 40 (01): : 308 - 316
  • [37] Prospective Trial to Compare Direct and Indirect Laryngoscopy Using C-MAC PM® with Macintosh Blade and D-Blade® in a Simulated Difficult Airway
    Raimann, Florian Juergen
    Dietze, Philipp Edmund
    Cuca, Colleen Elizabeth
    Meininger, Dirk
    Kessler, Paul
    Byhahn, Christian
    Gill-Schuster, Daniel
    Zacharowski, Kai
    Mutlak, Haitham
    EMERGENCY MEDICINE INTERNATIONAL, 2019, 2019
  • [38] The C-Mac Videolaryngoscope for Out-of-Hospital Use: A Prospective Multicenter Evaluation During Emergency Intubation
    Cavus, E.
    Callies, A.
    Doerges, V
    Merz, S.
    Heller, G.
    Steinfath, M.
    Helm, M.
    ANNALS OF EMERGENCY MEDICINE, 2010, 56 (03) : S24 - S24
  • [39] Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial
    Aziz, M. F.
    Bayman, E. O.
    Van Tienderen, M. M.
    Todd, M. M.
    Brambrink, A. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 118 - 123
  • [40] The C-MAC Videolaryngoscope: First Experiences with a New Device for Videolaryngoscopy-Guided Intubation
    Cavus, Erol
    Kieckhaefer, Joerg
    Doerges, Volker
    Moeller, Thora
    Thee, Carsten
    Wagner, Klaus
    ANESTHESIA AND ANALGESIA, 2010, 110 (02): : 473 - 477