Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: a randomized, controlled comparison in patients with suspected difficult airways

被引:1
|
作者
Serocki, G. [1 ]
Neumann, T. [1 ]
Scharf, E. [1 ]
Doerges, V. [1 ]
Cavus, E. [1 ]
机构
[1] Univ Hosp Schleswig Holstein UKSH, Dept Anesthesiol & Intens Care Med, D-24105 Kiel, Germany
关键词
Laryngoscopy; Airway management; Intubation; intratracheal; Laryngoscopes; TRACHEAL INTUBATION; ENDOTRACHEAL INTUBATION; DIRECT LARYNGOSCOPY; VIDEO-LARYNGOSCOPY; PREDICTIVE-VALUE; MANAGEMENT; ROUTINE; COMPLICATIONS;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Recently, indirect videolaryngoscopes have become increasingly important devices in difficult airway management. The aim of the present study was to investigate laryngoscopic view and intubation success using the new C-MAC* D-Blade in comparison to the established GlideScope* videolaryngoscope and conventional direct laryngoscopy in a randomized controlled trial. Methods. Ninety-six adult patients with expected difficult airways undergoing elective ear, nose and throat surgery (ENT) requiring general anesthesia were investigated. Repeated laryngoscopy was performed using a conventional direct Macintosh laryngoscope (DL), C-MAC D-Blade (DB) and GlideScope (GS) in a randomized sequence before patients were intubated with the last device used. Results. Both videolaryngoscopes showed significantly better C/L (Cormack-Lehane) classes than DL. Insufficient laryngoscopic view, defined as C/L >= III, was experienced in 18 patients (19.2%) with DL, in two patients with GS (2.1%) and in none with DB (0%). Time to best achievable laryngoscopic view did not differ between devices. Intubation time was significantly longer with both videolaryngoscopes (Median [Range] DB: 18 [8-33] s, and GS: 19 [9-34] s) than with DL (11 [5-26] s). However, intubation success was 100% for both DB and GS, whereas four patients could not be intubated using conventional direct laryngoscopy. Conclusion. Compared to direct Macintosh laryngoscopy, both C-MAC* D-Blade and GlideScope* comparably resulted in an improved view of the glottic opening with successful tracheal intubation in all patients. (Minerva Anestesiol 2013;79:121-9)
引用
收藏
页码:121 / 129
页数:9
相关论文
共 50 条
  • [1] Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial
    Aziz, M. F.
    Bayman, E. O.
    Van Tienderen, M. M.
    Todd, M. M.
    Brambrink, A. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 118 - 123
  • [2] Comparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways
    Kilicaslan, Alper
    Topal, Ahmet
    Erol, Atilla
    Uzun, Sema Tuncer
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2014, 42 (04) : 182 - 189
  • [3] D-blade C-MAC videolaryngoscopy™ with the Frova Intubating Introducer™
    Greenland, K. B.
    Bradley, P.
    ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (02) : 268 - 269
  • [4] GlideScope versus C-MAC D-blade videolaryngoscope for double-lumen tube intubation in patients with anticipated difficult airways: A multi-center, prospective, randomized, controlled trial
    Huang, Ping
    Qiu, Yuwei
    Xu, Ting
    Sun, Xiaoqiong
    Lu, Zhixing
    Zhang, Yunyun
    Yu, Jiangli
    Wu, Jingxiang
    Su, Diansan
    Huang, Zhenling
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 91
  • [5] Clinical evaluation of C-Mac D-Blade video laryngoscope: randomized comparison with C-Mac Blade and direct laryngoscopy
    Hostic, V.
    Maldini, B.
    Novotny, Z.
    Hodzovic, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E905 - E906
  • [6] Comparison of the C-MAC D-Blade videolaryngoscope and direct laryngoscope in pediatric patients: Randomized controlled trial
    Hajiyeva, Konul
    Can, Ozlem Selvi
    Baytas, Volkan
    Guclu, Cigdem Yildirim
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (04): : 421 - 426
  • [7] Comparison of C-MAC D-Blade with macintosh laryngoscope for endotracheal intubation in patients with cervical spine immobilization: A randomized controlled trial
    Agrawal, Nidhi
    Saini, Suman
    Gupta, Anju
    Kabi, Ankita
    Girdhar, K. K.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2021, 37 : 35 - 41
  • [8] A comparison of angled (D-Blade) and Macintosh (C-MAC) videolaryngoscopes for simulated pediatric difficult airway: a randomized single-blind study
    Kus, Alparslan
    Aksu, Can
    Yorukoglu, Hadi Ufuk
    Alparslan, Volkan
    Toker, Kamil
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2022, 52 (01) : 216 - 221
  • [9] Prospective Trial to Compare Direct and Indirect Laryngoscopy Using C-MAC PM® with Macintosh Blade and D-Blade® in a Simulated Difficult Airway
    Raimann, Florian Juergen
    Dietze, Philipp Edmund
    Cuca, Colleen Elizabeth
    Meininger, Dirk
    Kessler, Paul
    Byhahn, Christian
    Gill-Schuster, Daniel
    Zacharowski, Kai
    Mutlak, Haitham
    EMERGENCY MEDICINE INTERNATIONAL, 2019, 2019
  • [10] A Comparison of the Effectiveness of the McCoy Laryngoscope and the C-MAC D-Blade Video Laryngoscope in Obese Patients
    Lee, Jung-Min
    Lee, Soo-Kyung
    Jang, Minsoo
    Oh, Minho
    Park, Eun-Young
    MEDICINA-LITHUANIA, 2024, 60 (08):