Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: a randomized, controlled comparison in patients with suspected difficult airways

被引:1
|
作者
Serocki, G. [1 ]
Neumann, T. [1 ]
Scharf, E. [1 ]
Doerges, V. [1 ]
Cavus, E. [1 ]
机构
[1] Univ Hosp Schleswig Holstein UKSH, Dept Anesthesiol & Intens Care Med, D-24105 Kiel, Germany
关键词
Laryngoscopy; Airway management; Intubation; intratracheal; Laryngoscopes; TRACHEAL INTUBATION; ENDOTRACHEAL INTUBATION; DIRECT LARYNGOSCOPY; VIDEO-LARYNGOSCOPY; PREDICTIVE-VALUE; MANAGEMENT; ROUTINE; COMPLICATIONS;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Recently, indirect videolaryngoscopes have become increasingly important devices in difficult airway management. The aim of the present study was to investigate laryngoscopic view and intubation success using the new C-MAC* D-Blade in comparison to the established GlideScope* videolaryngoscope and conventional direct laryngoscopy in a randomized controlled trial. Methods. Ninety-six adult patients with expected difficult airways undergoing elective ear, nose and throat surgery (ENT) requiring general anesthesia were investigated. Repeated laryngoscopy was performed using a conventional direct Macintosh laryngoscope (DL), C-MAC D-Blade (DB) and GlideScope (GS) in a randomized sequence before patients were intubated with the last device used. Results. Both videolaryngoscopes showed significantly better C/L (Cormack-Lehane) classes than DL. Insufficient laryngoscopic view, defined as C/L >= III, was experienced in 18 patients (19.2%) with DL, in two patients with GS (2.1%) and in none with DB (0%). Time to best achievable laryngoscopic view did not differ between devices. Intubation time was significantly longer with both videolaryngoscopes (Median [Range] DB: 18 [8-33] s, and GS: 19 [9-34] s) than with DL (11 [5-26] s). However, intubation success was 100% for both DB and GS, whereas four patients could not be intubated using conventional direct laryngoscopy. Conclusion. Compared to direct Macintosh laryngoscopy, both C-MAC* D-Blade and GlideScope* comparably resulted in an improved view of the glottic opening with successful tracheal intubation in all patients. (Minerva Anestesiol 2013;79:121-9)
引用
收藏
页码:121 / 129
页数:9
相关论文
共 50 条
  • [31] Comparison of Force Distribution during Laryngoscopy with the C-MAC D-BLADE and Macintosh-Style Blades: A Randomised Controlled Clinical Trial
    Schmutz, Axel
    Breddin, Ingo
    Draxler, Ramona
    Schumann, Stefan
    Spaeth, Johannes
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (09)
  • [32] C1-C2 Motion During C-MAC D-Blade Videolaryngoscopy and Endotracheal Intubation in 2 Patients With Type II Odontoid Fractures: A Case Report
    Hindman, Bradley J.
    Woodroffe, Royce W.
    Zanaty, Mario
    Kawasaki, Hiroto
    Yamaguchi, Satoshi
    Puttlitz, Christian M.
    Gadomski, Benjamin C.
    A & A PRACTICE, 2019, 13 (04): : 121 - 123
  • [33] Comparison of Different Types of Stylets with No-Stylet Technique for Intubation with C-MAC D-Blade® Videolaryngoscope in Simulated Difficult Airway: A Prospective Randomised Study
    Goel, Rishika
    Anand, Lakesh Kumar
    Singh, Manpreet
    Jindal, Swati
    Rani, Mala
    Kaur, Arshdeep
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (06) : 445 - 452
  • [34] The performance of C-MAC videostylet versus D-Blade during tracheal intubation in patients with simulated cervical immobilization: A randomized comparative trial
    Anany, Adel Said Mohammed
    Arida, Emad Eldin Abd El Monem
    Oll, Magda Mohamed Abo
    Rida, Hossam El-Din Fouad
    El-Attar, Eman Ahmed Mohamed
    Hozien, Adel Ibrahim
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2024, 40 (01): : 308 - 316
  • [35] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Huang, Ping
    Zhou, Renlong
    Lu, Zhixing
    Hang, Yannan
    Wang, Shanjuan
    Huang, Zhenling
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [36] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Ping Huang
    Renlong Zhou
    Zhixing Lu
    Yannan Hang
    Shanjuan Wang
    Zhenling Huang
    BMC Anesthesiology, 20
  • [37] Bougie-assisted C-MAC video laryngoscope versus C-MAC video stylet for awake endoscopic intubation in anticipated difficult airways: A randomized controlled trial
    Falcetta, S.
    Borioni, M.
    Montozzi, A.
    Carsetti, A.
    Sorbello, M.
    Cataldo, R.
    Di Giacinto, I.
    Cerutti, E.
    Donati, A.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2023, 50
  • [38] The C-MAC® D-BLADE™: use of the guide rail as a guiding channel for a gum elastic bougie
    Jolin Wong
    Theodore G. L. Wong
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 901 - 902
  • [39] Comparison between C-MAC D-blade video laryngoscope and McCoy laryngoscope for nasotracheal intubation in traumatic cervical spine surgery - A randomised controlled trial
    Singh, Swati
    Kumar, Amit
    Kumar, Brajesh
    Singh, Swarnika
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (09) : 821 - 824
  • [40] Rational Design of End-Points to Evaluate Performance of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation Response
    Cavus, Erol
    Doerges, Volker
    Wagner, Klaus
    Serocki, Goetz
    ANESTHESIA AND ANALGESIA, 2011, 113 (01): : 203 - 204