First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation

被引:89
|
作者
Cavus, Erol [1 ]
Neumann, Tobias [1 ]
Doerges, Volker [1 ]
Moeller, Thora [2 ]
Scharf, Edwin [1 ]
Wagner, Klaus [2 ]
Bein, Berthold [1 ]
Serocki, Goetz [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Klinikum Suedstadt Rostock, Dept Anaesthesiol & Intens Care Med, Rostock, Germany
来源
ANESTHESIA AND ANALGESIA | 2011年 / 112卷 / 02期
关键词
TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; AIRWAY MANAGEMENT; EMERGENCY;
D O I
10.1213/ANE.0b013e31820553fb
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In the present preliminary study we evaluated the C-MAC (R) D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11(5-45) seconds and for successful intubation 17(3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required. (Anesth Analg 2011;112:382-5)
引用
收藏
页码:382 / 385
页数:4
相关论文
共 50 条
  • [21] Use of a flexible tip bougie (FlexTip) in the management of the first-attempt failure intubation with the C-MAC D-Blade videolaryngoscope in the intensive care unit: A prospective, case series
    Taboada, M.
    Carinena, A.
    Regueira, J.
    Francisco, C.
    Rodriguez, M.
    Seoane-Pillado, T.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2024, 71 (01): : 58 - 63
  • [22] Effectiveness of C-MAC video-stylet versus C-MAC D-blade video-laryngoscope for tracheal intubation in patients with predicted difficult airway: Randomized comparative study
    Osman, Yasser Mohamed
    Abd El-Aziz, Rehab Abd El-Raof
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2023, 39 (01): : 233 - 240
  • [23] Fibreoptic vs videolaryngoscopic (C-MAC® D-BLADE) nasal awake intubation under local anaesthesia
    Kramer, A.
    Mueller, D.
    Pfoertner, R.
    Mohr, C.
    Groeben, H.
    ANAESTHESIA, 2015, 70 (04) : 400 - 406
  • [24] THE D-BLADE™ IN THE C-MAC® SYSTEM SHOULD NOT BE USED AS A DIRECT LARYNGOSCOPE
    Norii, Tatsuya
    Crandall, Cameron
    Braude, Darren
    JOURNAL OF EMERGENCY MEDICINE, 2017, 52 (03): : E77 - E77
  • [25] Successful laryngoscope view using oversized C-Mac® D-blade in children presenting with difficult airway
    Tham, Kar Mun
    Liew, Clarabella W. T.
    Khoo, Charis E. H.
    Wang, Hao
    Dela Cruz, Janine
    Lie, Mandy Y. K.
    Hee, Hwan Ing
    ANAESTHESIA AND INTENSIVE CARE, 2022, 50 (05) : 396 - 399
  • [26] Comparison of propofol versus dexmedetomidine sedation for awake C-MAC® D-Blade video laryngoscopic nasotracheal intubation in patients with difficult airway: A randomised clinical study
    Vishnoi, Gunjan
    Shah, Shagun B.
    Chawla, Rajiv
    Bhardwaj, Manoj
    Patel, Anil
    Arora, Jenna
    INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (08) : 699 - 705
  • [27] Laryngeal papillomas: Not so innocent! C-MAC D-blade to the rescue
    Shah, S. B.
    Bhargava, A. K.
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2014, 22 (02): : 64 - 66
  • [28] Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
    Paik, Hyesun
    Park, Hee-Pyoung
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [29] Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine
    Hyesun Paik
    Hee-Pyoung Park
    BMC Anesthesiology, 20
  • [30] Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
    Aida Al-Qasmi
    Wafa Al-Alawi
    Azharuddin Mohammed Malik
    Rashid Manzoor Khan
    Naresh Kaul
    Trials, 14