Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation

被引:5
|
作者
Wang, Haifeng [1 ,2 ,5 ]
Liang, Dong [1 ]
Su, Shi [1 ]
King, Kevin F. [3 ]
Chang, Yuchou [4 ]
Liu, Xin [1 ]
Zheng, Hairong [1 ]
Ying, Leslie [2 ,5 ]
机构
[1] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen, Guangdong, Peoples R China
[2] SUNY Buffalo, Dept Elect Engn & Biomed Engn, Buffalo, NY USA
[3] GE Healthcare, Global Appl Sci Lab, Waukesha, WI USA
[4] Univ Houston Downtown, Dept Comp Sci & Engn Technol, Houston, TX USA
[5] Univ Buffalo, State Univ New York,Dept Elect Engn,SUNY, BioMed Engn, Buffalo, NY USA
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
compressed sensing; knee imaging; phase scrambling; Toeplitz encoding; PARALLEL MRI; RECONSTRUCTION; FOURIER; COMBINATION; PRINCIPLES; RESOLUTION;
D O I
10.1002/mp.13987
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardware requirement, and signal-to-noise ratio (SNR) improvement. Methods In light of the actual imaging framework of magnetic resonance imaging (MRI) scanners, we applied specially tailored RF pulses with phase-scrambled RF excitation to implement a 3D hybrid Fourier-Toeplitz encoding method based on 3D gradient-recalled echo pulse (GRASS) sequence. This method exploits Toeplitz encoding along the phase encoding direction, while keeping Fourier encoding along the readout and slice encoding directions. Phantom experiments were conducted to optimize the amplitude of specially tailored RF pulses in the 3D GRASS sequence. In vivo experiments were conducted to validate the feasibility of the proposed method, and simulations were conducted to compare the 3D hybrid-encoding method with Fourier encoding and other non-Fourier encoding methods. Results An optimized low RF amplitude was obtained in the phantom experiments. Using the optimized specially tailored RF pulses, both the watermelon and knee experiments demonstrated that the proposed method was able to preserve more image details than the conventional 3D Fourier-encoded methods at acceleration factors of 3.1 and 2.0. Additionally, SNR was improved because of no additional gradients and 3D volume encoding, when compared with single-slice scanning without 3D encoding. Simulation results demonstrated that the proposed scheme was superior to the conventional Fourier encoding method, and obtained comparative performance with other non-Fourier encoding methods in preserving details. Conclusions We developed a practical hybrid-encoding method for 3D MRI with specially tailored RF pulses of phase-scrambled RF excitation. The proposed method improves image SNR and detail preservation compared with the conventional Fourier encoding methods. Furthermore, our proposed method exhibits superior performance in terms of detail preservation, compared with the conventional Fourier encoding method.
引用
收藏
页码:1579 / 1589
页数:11
相关论文
共 50 条
  • [21] Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion
    Weaver, JB
    Van Houten, EEW
    Miga, MI
    Kennedy, FE
    Paulsen, KD
    MEDICAL PHYSICS, 2001, 28 (08) : 1620 - 1628
  • [22] Reduced Imaging Time and Improved Image Quality of 3D Isotropic T2-Weighted Magnetic Resonance Imaging with Compressed Sensing for the Female Pelvis
    Hao M.
    Feng X.
    Ming D.
    Journal of Beijing Institute of Technology (English Edition), 2023, 32 (05): : 579 - 585
  • [23] Reduced Imaging Time and Improved Image Quality of 3D Isotropic T2-Weighted Magnetic Resonance Imaging with Compressed Sensing for the Female Pelvis
    Hao Mei
    Feng Xiao
    Ming Deng
    JournalofBeijingInstituteofTechnology, 2023, 32 (05) : 579 - 585
  • [24] Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging
    Murphy, BJ
    SKELETAL RADIOLOGY, 2001, 30 (06) : 305 - 311
  • [25] Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging
    B. J. Murphy
    Skeletal Radiology, 2001, 30 : 305 - 311
  • [26] Rapid MR Angiography Using 3D Gradient-echo Imaging and the Two-point Dixon Method to Evaluate Carotid Plaque
    Irie, Ryusuke
    Amemiya, Shiori
    Ueyama, Tsuyoshi
    Suzuki, Yuichi
    Takao, Hidemasa
    Abe, Osamu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2023, 22 (03) : 373 - 378
  • [27] Carotid and aortic plaque imaging using 3D gradient-echo imaging and the three-point Dixon method with improved motion-sensitized driven-equilibrium (iMSDE)
    Koori, Norikazu
    Kamekawa, Hiroki
    Naito, Takehiro
    Takatsu, Yasuo
    Fuse, Hiraku
    Miyakawa, Shin
    Yasue, Kenji
    Takahashi, Masato
    Kurata, Kazuma
    MAGNETIC RESONANCE IMAGING, 2024, 111 : 202 - 209
  • [28] An equal-TE ultrafast 3D gradient-echo imaging method with high tolerance to magnetic susceptibility artifacts: Application to BOLD functional MRI
    Ryu, Jae-Kyun
    Jung, Won Beom
    Yu, Jaeyong
    Son, Jeong Pyo
    Lee, Seung-Kyun
    Kim, Seong-Gi
    Park, Jang-Yeon
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1986 - 2000
  • [29] Rapid identification and 3D reconstruction of complex cardiac malformations in transgenic mouse embryos using fast gradient echo sequence magnetic resonance imaging
    Schneider, JE
    Bamforth, SD
    Farthing, CR
    Clarke, K
    Neubauer, S
    Bhattacharya, S
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2003, 35 (02) : 217 - 222
  • [30] Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging
    van Gorp, Jetse S.
    Bakker, Chris J. G.
    Bouwman, Job G.
    Smink, Jouke
    Zijlstra, Frank
    Seevinck, Peter R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 615 - 631