Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation

被引:5
|
作者
Wang, Haifeng [1 ,2 ,5 ]
Liang, Dong [1 ]
Su, Shi [1 ]
King, Kevin F. [3 ]
Chang, Yuchou [4 ]
Liu, Xin [1 ]
Zheng, Hairong [1 ]
Ying, Leslie [2 ,5 ]
机构
[1] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen, Guangdong, Peoples R China
[2] SUNY Buffalo, Dept Elect Engn & Biomed Engn, Buffalo, NY USA
[3] GE Healthcare, Global Appl Sci Lab, Waukesha, WI USA
[4] Univ Houston Downtown, Dept Comp Sci & Engn Technol, Houston, TX USA
[5] Univ Buffalo, State Univ New York,Dept Elect Engn,SUNY, BioMed Engn, Buffalo, NY USA
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
compressed sensing; knee imaging; phase scrambling; Toeplitz encoding; PARALLEL MRI; RECONSTRUCTION; FOURIER; COMBINATION; PRINCIPLES; RESOLUTION;
D O I
10.1002/mp.13987
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardware requirement, and signal-to-noise ratio (SNR) improvement. Methods In light of the actual imaging framework of magnetic resonance imaging (MRI) scanners, we applied specially tailored RF pulses with phase-scrambled RF excitation to implement a 3D hybrid Fourier-Toeplitz encoding method based on 3D gradient-recalled echo pulse (GRASS) sequence. This method exploits Toeplitz encoding along the phase encoding direction, while keeping Fourier encoding along the readout and slice encoding directions. Phantom experiments were conducted to optimize the amplitude of specially tailored RF pulses in the 3D GRASS sequence. In vivo experiments were conducted to validate the feasibility of the proposed method, and simulations were conducted to compare the 3D hybrid-encoding method with Fourier encoding and other non-Fourier encoding methods. Results An optimized low RF amplitude was obtained in the phantom experiments. Using the optimized specially tailored RF pulses, both the watermelon and knee experiments demonstrated that the proposed method was able to preserve more image details than the conventional 3D Fourier-encoded methods at acceleration factors of 3.1 and 2.0. Additionally, SNR was improved because of no additional gradients and 3D volume encoding, when compared with single-slice scanning without 3D encoding. Simulation results demonstrated that the proposed scheme was superior to the conventional Fourier encoding method, and obtained comparative performance with other non-Fourier encoding methods in preserving details. Conclusions We developed a practical hybrid-encoding method for 3D MRI with specially tailored RF pulses of phase-scrambled RF excitation. The proposed method improves image SNR and detail preservation compared with the conventional Fourier encoding methods. Furthermore, our proposed method exhibits superior performance in terms of detail preservation, compared with the conventional Fourier encoding method.
引用
收藏
页码:1579 / 1589
页数:11
相关论文
共 50 条
  • [41] Validation of Perfusion Quantification with 3D Gradient Echo Dynamic Contrast-nhanced Magnetic Resonance Imaging Using a Blood Pool Contrast Agent in Skeletal Swine Muscle
    Hindel, Stefan
    Sauerbrey, Anika
    Maass, Marc
    Maderwald, Stefan
    Schlamann, Marc
    Luedemann, Lutz
    PLOS ONE, 2015, 10 (06):
  • [42] HIGH-RESOLUTION MR-IMAGING OF THE LUNATOTRIQUETRAL LIGAMENT - COMPARISON OF ROUTINE SE, THIN-SECTION SE, AND 3D GRADIENT-ECHO SEQUENCES WITH 3-PHASE ARTHROGRAPHY
    UNDERBERGDAVIS, SJ
    RUBIN, DA
    OSTERMAN, AL
    KNEELAND, JB
    JESMANOWICZ, A
    SCHNALL, MD
    RADIOLOGY, 1992, 185 : 193 - 193
  • [43] High-Resolution Magnetic Resonance Imaging of the Inferior Alveolar Nerve Using 3-Dimensional Magnetization-Prepared Rapid Gradient-Echo Sequence at 3.0T
    Deng, Wei
    Chen, Song-Ling
    Zhang, Zhong-Wei
    Huang, Dai-Ying
    Zhang, Xing
    Li, Xiang
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (12) : 2621 - 2626
  • [44] Accelerating Brain 3D T1-Weighted Turbo Field Echo MRI Using Compressed Sensing-Sensitivity Encoding (CS-SENSE)
    Duan, Yunyun
    Zhang, Jie
    Zhuo, Zhizheng
    Ding, Jinli
    Ju, Rongkai
    Wang, Jiazheng
    Ma, Tingting
    Haller, Sven
    Liu, Yong
    Liu, Yaou
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
  • [45] Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging
    Benkert, Thomas
    Block, Kai Tobias
    Heller, Samantha
    Moccaldi, Melanie
    Sodickson, Daniel K.
    Kim, Sungheon Gene
    Moy, Linda
    INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 583 - 589
  • [46] Evaluation of heterogeneous metabolic profile in an orthotopic human glioblastoma xenograft model using compressed sensing hyperpolarized 3D 13C magnetic resonance spectroscopic imaging
    Park, Ilwoo
    Hu, Simon
    Bok, Robert
    Ozawa, Tomoko
    Ito, Motokazu
    Mukherjee, Joydeep
    Phillips, Joanna J.
    James, C. David
    Pieper, Russell O.
    Ronen, Sabrina M.
    Vigneron, Daniel B.
    Nelson, Sarah J.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 33 - 39
  • [47] Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses
    Mitsouras, D
    Mulkern, RV
    Rybicki, FJ
    MEDICAL PHYSICS, 2006, 33 (01) : 173 - 186
  • [48] Improvement of the Diagnostic Performance of Facial Neuritis Using Contrast-Enhanced 3D T1 Black-Blood Imaging: Comparison with Contrast-Enhanced 3D T1-Spoiled Gradient-Echo Imaging
    Lee, Seun-Ah
    Jo, Sang-Won
    Chang, Suk-Ki
    Kwon, Ki-Han
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [49] Microscale 3D imaging by magnetic resonance force microscopy using full-volume Fourier- and Hadamard-encoding
    Schnoz, Sebastian
    Hunkeler, Andreas
    Dapp, Alexander
    Kamberger, Robert
    Korvink, Jan G.
    Meier, Beat H.
    JOURNAL OF MAGNETIC RESONANCE, 2019, 299 : 196 - 201
  • [50] Serial follow-up of left ventricular parameters using real-time 3D echo is comparable to magnetic resonance imaging and superior to 2D echo
    Jenkins, C
    Hanekom, L
    Chan, J
    Marwick, TH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 264A - 264A