Comparison of ultrasonic pachymetry with orbscan in corneal haze

被引:14
|
作者
Altan-Yaycioglu, Rana
Pelit, Aysel
Akova, Yonca Aydin
机构
[1] Baskent Univ Adana, Teaching & Med Res Ctr, Dept Ophthalmol, TR-01250 Adana, Turkey
[2] Baskent Univ, Dept Ophthalmol, Fac Med, TR-06490 Ankara, Turkey
关键词
corneal topography; corneal opacity; keratitis; trachoma; corneal dystrophy;
D O I
10.1007/s00417-007-0578-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To compare the results of ultrasonic and Orbscan pachymetry in corneal haze not related to surgery. Methods An institutionally based, prospective, controlled clinical trial included 40 eyes of 40 consecutive patients with corneal haze not related to surgery. Fifty normal eyes were used as a control group to calculate the customized acoustic factor. Corneal haze was graded with slit-lamp by a single examiner. Ultrasonic and Orbscan II pachymetry measurements were obtained. Paired t- and Kruskal-Wallis tests were used to evaluate the difference between ultrasonic and Orbscan pachymetry measurements. Correlation of the two methods and haze grade were determined with Kendall's tau-b correlation analysis. Results Eighty-five percent of patients had moderate haze. With the customized acoustic factor, Orbscan values were significantly smaller than ultrasonic pachymetry measurements (p=0.001, paired samplet-test). Increased haze grade resulted in smaller Orbscan pachymetry measurements however, this difference was insignificant (p=0.444, Kruskal-Wallis test). A positive correlation was found between two methods, though insignificant (p=0.064, Kendall's tau-b correlation). When grouped in respect of diagnoses, differences in pachymetry measurements as well as the correlation were not significant (p > 0.05). Conclusions An insignificant positive correlation was found between the two methods in the presence of corneal haze. Orbscan measurements were inversely related to haze grading, and were significantly lower than ultrasonic pachymetry. According to our results, we recommend that clinicians should not count on Orbscan topography alone in the presence of corneal haze.
引用
收藏
页码:1759 / 1763
页数:5
相关论文
共 50 条
  • [21] Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    González-Méijome, JM
    Cerviño, A
    Yebra-Pimentel, E
    Parafita, MA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 125 - 132
  • [22] CANINE CORNEAL THICKNESS MEASURED BY ULTRASONIC PACHYMETRY
    GILGER, BC
    WHITLEY, D
    MCLAUGHLIN, SA
    WRIGHT, JC
    DRANE, JW
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1991, 52 (10) : 1570 - 1572
  • [23] Central corneal thickness measurements in unoperated eyes and eyes after PRK for orbscan II and myopia using pentacam, ultrasonic pachymetry
    Kim, Sun Woong
    Byun, Yeo Jue
    Byun, Yeo Jue
    Kim, Eung Kweon
    Kim, Taeim
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (09) : 888 - 894
  • [24] Comparison of central corneal thickness measurements with standard ultrasonic pachymetry and optical devices
    Dogan, Mustafa
    Ertan, Elif
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (02) : 126 - 130
  • [25] CORNEAL THICKNESS MEASURED BY ULTRASONIC PACHYMETRY IN CATS
    GILGER, BC
    WRIGHT, JC
    WHITLEY, RD
    MCLAUGHLIN, SA
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1993, 54 (02) : 228 - 230
  • [26] A Comparison of Central Corneal Thickness Measured using Noncontact Methods and Ultrasonic Pachymetry
    Toptan, M.
    Simsek, A.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (10) : 1506 - 1510
  • [27] ULTRASONIC PACHYMETRY DETERMINATION OF CORNEAL THICKNESS IN THE RAT
    KOVACH, K
    BOUCHARD, CS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 894 - 894
  • [28] Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry
    Al-Mezaine H.S.
    Al-Amro S.A.
    Kangave D.
    Sadaawy A.
    Wehaib T.A.
    Al-Obeidan S.
    International Ophthalmology, 2008, 28 (5) : 333 - 338
  • [29] Precision of corneal thickness measurements from reflection spectra: Comparison with Orbscan, optical coherence tomography and ultrasound pachymetry.
    Markakis, GA
    King-Smith, PE
    Roberts, CJ
    Lembach, RG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S528 - S528
  • [30] Central corneal thickness measurements using Orbscan II scanning slit topography, noncontact specular microscopy, and ultrasonic pachymetry in eyes with keratoconus
    Kawana, K
    Miyata, K
    Tokunaga, T
    Kiuchi, T
    Hiraoka, T
    Oshika, T
    CORNEA, 2005, 24 (08) : 967 - 971