CANINE CORNEAL THICKNESS MEASURED BY ULTRASONIC PACHYMETRY

被引:0
|
作者
GILGER, BC
WHITLEY, D
MCLAUGHLIN, SA
WRIGHT, JC
DRANE, JW
机构
[1] AUBURN UNIV,COLL VET MED,DEPT SMALL ANIM SURG & MED,AUBURN,AL 36849
[2] UNIV S CAROLINA,SCH PUBL HLTH,DEPT EPIDEMIOL & BIOSTAT,COLUMBIA,SC 29208
[3] AUBURN UNIV,COLL VET MED,DEPT PATHOBIOL,AUBURN,AL 36849
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Ultrasonic pachymetry was used to measure central, superior peripheral, and temporal peripheral corneal thicknesses of 75 dogs (150 eyes) with normal corneas, anterior chambers, and intraocular pressure. Mean corneal thickness averaged over the 2 eyes, 3 locations, and 75 dogs was 562 +/- 6.2-mu-m. The peripheral cornea was thicker on average than the central cornea by 49.43 +/- 8.45-mu-m and this difference increased with age at 6.97 +/- 1.3-mu-m/month of age. Mean corneal thickness changed with age (14.23 +/- 2.26-mu-m/month), and weight (1.83 +/- 0.38-mu-m/kg). Females had significantly thinner corneas (22.43 +/- 11.03-mu-m than males) after adjusting for age and weight.
引用
收藏
页码:1570 / 1572
页数:3
相关论文
共 50 条
  • [1] CORNEAL THICKNESS MEASURED BY ULTRASONIC PACHYMETRY IN CATS
    GILGER, BC
    WRIGHT, JC
    WHITLEY, RD
    MCLAUGHLIN, SA
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 1993, 54 (02) : 228 - 230
  • [2] A Comparison of Central Corneal Thickness Measured using Noncontact Methods and Ultrasonic Pachymetry
    Toptan, M.
    Simsek, A.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (10) : 1506 - 1510
  • [3] ULTRASONIC PACHYMETRY DETERMINATION OF CORNEAL THICKNESS IN THE RAT
    KOVACH, K
    BOUCHARD, CS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 894 - 894
  • [4] Corneal thickness in pigs measured by ultrasound pachymetry in vivo
    Faber, Carsten
    Scherfig, Erik
    Prause, Jan Ulrik
    Sorensen, Knud Erik
    [J]. SCANDINAVIAN JOURNAL OF LABORATORY ANIMAL SCIENCE, 2008, 35 (01) : 39 - 43
  • [5] Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
    Demir, Semra Tiryaki
    Odabasi, Mahmut
    Oba, Mehmet Ersin
    Dirim, Ayse Burcu
    Can, Efe
    Kara, Orhan
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 263 - 267
  • [6] Comparison of Central Corneal Thickness Measured by Tono-pachymetry and Ultrasound Pachymetry
    Park, Hye Yeon
    Shin, Hye-Young
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (07): : 904 - 909
  • [7] Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method
    Thomas, Joseph
    Wang, Jianhua
    Rollins, Andrew M.
    Sturm, Julie
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 671 - 678
  • [8] Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    Yaylali, V
    Kaufman, SC
    Thompson, HW
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1345 - 1350
  • [9] Corneal thickness measurements with contact and noncontact specular microscopic and ultrasonic pachymetry
    Modis, L
    Langenbucher, A
    Seitz, B
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (04) : 517 - 521
  • [10] Use of ultrasonic pachymetry for measurement of changes in corneal thickness in mouse corneal transplant rejection
    Flynn, T. H.
    Ohbayashi, M.
    Dawson, M.
    Siddique, M.
    Ono, S. J.
    Larkin, D. F. P.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (03) : 368 - 371