Use of ultrasonic pachymetry for measurement of changes in corneal thickness in mouse corneal transplant rejection

被引:11
|
作者
Flynn, T. H. [1 ,2 ]
Ohbayashi, M. [3 ]
Dawson, M. [2 ]
Siddique, M. [2 ]
Ono, S. J. [2 ,3 ]
Larkin, D. F. P. [1 ,2 ]
机构
[1] Moorfields Eye Hosp, London EC1V 2PD, England
[2] UCL, Inst Ophthalmol, Dept Ocular Immunol, London, England
[3] Emory Univ, Emory Eye Ctr, Dobbs Ocular Immunol Labs, Atlanta, GA 30322 USA
关键词
ALLOGRAFT-REJECTION; EXPRESSION; RAT;
D O I
10.1136/bjo.2009.160671
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims Diagnosis of rejection in the mouse model of corneal transplantation is based on subjective judgement of loss of graft transparency. The aims of this study were to (1) evaluate a pachymetry technique to measure changes in mouse corneal thickness and (2) correlate increases in transplant thickness with clinical and histological features of rejection. Methods Orthotopic corneal allografts (C57BL/6 strain donor) and syngeneic grafts were performed in A/J mice. Graft transparency was graded and corneal thickness measured by pachymetry on alternate days. Transverse sections of donor cornea excised from eyes representative of clinical opacity grades 1-4 were prepared, photographed, graft section thickness measured and stromal graft-infiltrating cells counted. Intraobserver and interobserver variations in pachymetry were statistically tested. Results Graft thickness, as measured by pachymetry, increased with each clinical opacity grade. Thickness for opacity grades 0, 1 and 2 was less than 300 mu m in all recipients. Graft thickness for grades 3 and 4 was greater than 300 mu min all cases. For measurements up to 400 mu m, there was a good correlation between thickness as measured by in vivo pachymetry and in histopathological sections. The mean interobserver bias was -11.35 mu m, while the mean intraobserver bias was +3.96 mu m. Stromal cellularity increased with increasing corneal thickness up to approximately 300 mu m. Conclusion In vivo graft pachymetry provides a new and reliable way to objectively diagnose rejection in the mouse model of corneal transplantation.
引用
收藏
页码:368 / 371
页数:4
相关论文
共 50 条
  • [1] ULTRASONIC PACHYMETRY OF CORNEAL TRANSPLANT REJECTION IN A RABBIT MODEL
    KING, KM
    BOUCHARD, CS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 984 - 984
  • [2] CANINE CORNEAL THICKNESS MEASURED BY ULTRASONIC PACHYMETRY
    GILGER, BC
    WHITLEY, D
    MCLAUGHLIN, SA
    WRIGHT, JC
    DRANE, JW
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 1991, 52 (10) : 1570 - 1572
  • [3] CORNEAL THICKNESS MEASURED BY ULTRASONIC PACHYMETRY IN CATS
    GILGER, BC
    WRIGHT, JC
    WHITLEY, RD
    MCLAUGHLIN, SA
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 1993, 54 (02) : 228 - 230
  • [4] ULTRASONIC PACHYMETRY DETERMINATION OF CORNEAL THICKNESS IN THE RAT
    KOVACH, K
    BOUCHARD, CS
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 894 - 894
  • [5] Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
    Demir, Semra Tiryaki
    Odabasi, Mahmut
    Oba, Mehmet Ersin
    Dirim, Ayse Burcu
    Can, Efe
    Kara, Orhan
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 263 - 267
  • [6] Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    Yaylali, V
    Kaufman, SC
    Thompson, HW
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1345 - 1350
  • [7] Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease
    Hoehn, A. L.
    Thomasy, S. M.
    Kass, P. H.
    Horikawa, T.
    Samuel, M.
    Shull, O. R.
    Stewart, K. A.
    Murphy, C. J.
    [J]. VETERINARY JOURNAL, 2018, 242 : 59 - 66
  • [8] Mouse corneal transplant evaluation with topography and pachymetry using OCT
    Song, Ailin
    Liu, Alice
    Li, Guorong
    Li, Liwen
    Farsiu, Sina
    Stamer, Dan
    Perez, Stamer Victor L.
    McNabb, Ryan P.
    Kuo, Anthony N.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Agreement of Corneal Thickness Measurement Using Slitlamp and Ultrasound Pachymetry
    Agarwal, Tushar
    Bhartiya, Shibal
    Dada, Tanuj
    Panda, Anita
    Jhanji, Vishal
    Yu, Marco
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (04): : 231 - 233
  • [10] Accuracy of RTVue Optical Coherence Tomography, Pentacam, and Ultrasonic Pachymetry for the Measurement of Central Corneal Thickness
    Nam, Sang Min
    Im, Chan Young
    Lee, Hyung Keun
    Kim, Eung Kweon
    Kim, Tae-im
    Seo, Kyoung Yul
    [J]. OPHTHALMOLOGY, 2010, 117 (11) : 2096 - 2103