Comparison of ultrasonic pachymetry with orbscan in corneal haze

被引:14
|
作者
Altan-Yaycioglu, Rana
Pelit, Aysel
Akova, Yonca Aydin
机构
[1] Baskent Univ Adana, Teaching & Med Res Ctr, Dept Ophthalmol, TR-01250 Adana, Turkey
[2] Baskent Univ, Dept Ophthalmol, Fac Med, TR-06490 Ankara, Turkey
关键词
corneal topography; corneal opacity; keratitis; trachoma; corneal dystrophy;
D O I
10.1007/s00417-007-0578-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To compare the results of ultrasonic and Orbscan pachymetry in corneal haze not related to surgery. Methods An institutionally based, prospective, controlled clinical trial included 40 eyes of 40 consecutive patients with corneal haze not related to surgery. Fifty normal eyes were used as a control group to calculate the customized acoustic factor. Corneal haze was graded with slit-lamp by a single examiner. Ultrasonic and Orbscan II pachymetry measurements were obtained. Paired t- and Kruskal-Wallis tests were used to evaluate the difference between ultrasonic and Orbscan pachymetry measurements. Correlation of the two methods and haze grade were determined with Kendall's tau-b correlation analysis. Results Eighty-five percent of patients had moderate haze. With the customized acoustic factor, Orbscan values were significantly smaller than ultrasonic pachymetry measurements (p=0.001, paired samplet-test). Increased haze grade resulted in smaller Orbscan pachymetry measurements however, this difference was insignificant (p=0.444, Kruskal-Wallis test). A positive correlation was found between two methods, though insignificant (p=0.064, Kendall's tau-b correlation). When grouped in respect of diagnoses, differences in pachymetry measurements as well as the correlation were not significant (p > 0.05). Conclusions An insignificant positive correlation was found between the two methods in the presence of corneal haze. Orbscan measurements were inversely related to haze grading, and were significantly lower than ultrasonic pachymetry. According to our results, we recommend that clinicians should not count on Orbscan topography alone in the presence of corneal haze.
引用
收藏
页码:1759 / 1763
页数:5
相关论文
共 50 条
  • [31] Analysis of the corneal thickness with Orbscan II and ultrasonic pachymeter
    Kopito, R
    Touzeau, O
    Allouch, C
    Borderie, VM
    Laroche, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U131 - U131
  • [32] Orbscan pachymetry after LASIK is not reliable
    Giessler, S
    Duncker, GIW
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (03) : 385 - 387
  • [33] Scanning-slit and specular microscopic pachymetry in comparison with ultrasonic determination of corneal thickness
    Modis, L
    Langenbucher, A
    Seitz, B
    CORNEA, 2001, 20 (07) : 711 - 714
  • [34] Coefficient of repeatability of the ultrasonic corneal pachymetry of cadaver eyes
    Sousa, Sidney Julio
    Sampaio, Daniela
    Gomes Vieira, Monike de Paula
    Gondim Ramos Sobral, Regia Maria
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [35] Repeatability of ORBSCAN pachymetry measures in keratoconus
    Riley, C
    Kollbaum, P
    Lowther, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U891 - U891
  • [36] Comparison of central corneal thickness measurements by ultrasound pachymetry, Orbscan, and third generation optical coherence tomography (OCT3)
    Fishman, GR
    Pons, M
    Makornwattana, M
    Seedor, J
    Liebmann, J
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U5 - U5
  • [37] ULTRASONIC PACHYMETRY OF CORNEAL TRANSPLANT REJECTION IN A RABBIT MODEL
    KING, KM
    BOUCHARD, CS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 984 - 984
  • [38] Comparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan
    Khaja, Wassia A.
    Grover, Sandeep
    Kelmenson, Amy T.
    Ferguson, Lee R.
    Sambhav, Kumar
    Chalam, Kakarla V.
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1065 - 1070
  • [39] Comparison of Spectral Domain Optical Coherence Tomography and Ultrasonic Pachymetry for Assessment of Central Corneal Thickness
    Celebi, Ali Riza Cenk
    Mirza, G. Ertugrul
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 259 - 262
  • [40] Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method
    Thomas, Joseph
    Wang, Jianhua
    Rollins, Andrew M.
    Sturm, Julie
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 671 - 678