Comparison of ultrasonic pachymetry with orbscan in corneal haze

被引:14
|
作者
Altan-Yaycioglu, Rana
Pelit, Aysel
Akova, Yonca Aydin
机构
[1] Baskent Univ Adana, Teaching & Med Res Ctr, Dept Ophthalmol, TR-01250 Adana, Turkey
[2] Baskent Univ, Dept Ophthalmol, Fac Med, TR-06490 Ankara, Turkey
关键词
corneal topography; corneal opacity; keratitis; trachoma; corneal dystrophy;
D O I
10.1007/s00417-007-0578-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To compare the results of ultrasonic and Orbscan pachymetry in corneal haze not related to surgery. Methods An institutionally based, prospective, controlled clinical trial included 40 eyes of 40 consecutive patients with corneal haze not related to surgery. Fifty normal eyes were used as a control group to calculate the customized acoustic factor. Corneal haze was graded with slit-lamp by a single examiner. Ultrasonic and Orbscan II pachymetry measurements were obtained. Paired t- and Kruskal-Wallis tests were used to evaluate the difference between ultrasonic and Orbscan pachymetry measurements. Correlation of the two methods and haze grade were determined with Kendall's tau-b correlation analysis. Results Eighty-five percent of patients had moderate haze. With the customized acoustic factor, Orbscan values were significantly smaller than ultrasonic pachymetry measurements (p=0.001, paired samplet-test). Increased haze grade resulted in smaller Orbscan pachymetry measurements however, this difference was insignificant (p=0.444, Kruskal-Wallis test). A positive correlation was found between two methods, though insignificant (p=0.064, Kendall's tau-b correlation). When grouped in respect of diagnoses, differences in pachymetry measurements as well as the correlation were not significant (p > 0.05). Conclusions An insignificant positive correlation was found between the two methods in the presence of corneal haze. Orbscan measurements were inversely related to haze grading, and were significantly lower than ultrasonic pachymetry. According to our results, we recommend that clinicians should not count on Orbscan topography alone in the presence of corneal haze.
引用
收藏
页码:1759 / 1763
页数:5
相关论文
共 50 条
  • [1] Comparison of ultrasonic pachymetry with orbscan in corneal haze
    Rana Altan-Yaycioglu
    Aysel Pelit
    Yonca Aydin Akova
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1759 - 1763
  • [2] Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
    Demir, Semra Tiryaki
    Odabasi, Mahmut
    Oba, Mehmet Ersin
    Dirim, Ayse Burcu
    Can, Efe
    Kara, Orhan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 263 - 267
  • [3] Comparison of central corneal thickness measurements obtained by ultrasonic pachymetry and the Orbscan Topography System
    Hsu, J
    Grossman, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S902 - S902
  • [4] Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    Yaylali, V
    Kaufman, SC
    Thompson, HW
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1345 - 1350
  • [5] Comparison of corneal pachymetry using ultrasound and Orbscan II
    Fakhry, MA
    Artola, A
    Belda, JL
    Ayala, MJ
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 248 - 252
  • [6] Accuracy and reproducibility of the Orbscan pachymetry and ultrasonic pachymetry
    Touzeau, O
    Allouch, C
    Borderie, V
    Ameline, B
    Chastang, P
    Bouzegaou, F
    Laroche, L
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2001, 24 (09): : 912 - 921
  • [7] Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry Orbscan II, and optical coherence tomography
    Haque, S
    Simpson, T
    Jones, L
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (05) : 486 - 493
  • [8] Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry, orbscan and optical coherence tomography measurements
    Haque, S
    Jones, L
    Simpson, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U28 - U28
  • [9] Accuracy of Orbscan optical pachymetry in corneas with haze
    Boscia, F
    La Tegola, MG
    Alessio, G
    Sborgia, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 253 - 258
  • [10] Comparison of Orbscan and Ultrasound pachymetry in the measurement of central corneal thickness
    S W Radford
    R Lim
    J F Salmon
    Eye, 2004, 18 : 434 - 436