Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry Orbscan II, and optical coherence tomography

被引:96
|
作者
Haque, S [1 ]
Simpson, T [1 ]
Jones, L [1 ]
机构
[1] Univ Waterloo, Sch Optometry, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.3928/1081-597X-20060501-11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare corneal thickness measurements in individuals with keratoconus using optical coherence tomography (OCT), Orbscan II, and ultrasonic pachymetry and to measure epithelial and stromal thickness in these individuals using OCT. METHODS: Twenty individuals with keratoconus and 20 controls (without keratoconus) were enrolled. The Orbscan If was used to locate the steepest area of the cornea, which was taken to represent the cone apex. Each instrument was used to obtain four total corneal thickness measurements-from the cone apex, corneal center, mid-nasal, and mid-temporal cornea. Optical coherence tomography scans were analyzed to provide epithelial and stromal thickness readings. RESULTS: In individuals with keratoconus, mean central corneal thickness (CCT) measured by ultrasonic pachymetry Orbscan, and OCT was 494.2 +/- 50.0 mu m, 438.6 +/- 47.7 mu m, and 433.5 +/- 39.7 mu m, respectively. The central keratoconic cornea was 57.7 mu m thinner than the normal cornea (post-hoc P<.001). The cone apex was thinner than the central cornea (P<.001). Keratoconic epithelium was 48.2 +/- 5.5 mu m centrally and 42.1 +/- 4.5 mu m at the apex. Central keratoconic epithelium was 4.7 mu m thinner and central keratoconic stroma was 57.8 mu m thinner than the normal cornea (P<.001, respectively). Comparing instruments, Orbscan and OCT correlated in CCT measurement (r=0.890) and apical thickness (r=0.846). All instruments produced similar readings for mid-nasal and mid-temporal corneal thickness in participants with keratoconus (P>.05). CONCLUSIONS: Ultrasonic pachymetry produced the highest corneal thickness readings in the center and apex, compared to Orbscan 11 and OCT Centrally, the total cornea, epithelium, and stroma were thinner in individuals with keratoconus than in normal individuals.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [1] Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry, orbscan and optical coherence tomography measurements
    Haque, S
    Jones, L
    Simpson, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U28 - U28
  • [2] Comparison of Central Corneal Thickness Measurements by Ultrasonic Pachymetry and Orbscan II Corneal Topography and Evaluation of Ultrasonic Pachymetry Repeatability
    Demir, Semra Tiryaki
    Odabasi, Mahmut
    Oba, Mehmet Ersin
    Dirim, Ayse Burcu
    Can, Efe
    Kara, Orhan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 263 - 267
  • [3] Corneal Thickness in Keratoconus Comparing Optical, Ultrasound, and Optical Coherence Tomography Pachymetry
    Dutta, Debarun
    Rao, Harsha L.
    Addepalli, Uday K.
    Vaddavalli, Pravin K.
    OPHTHALMOLOGY, 2013, 120 (03) : 457 - 463
  • [4] Comparison of Spectral Domain Optical Coherence Tomography and Ultrasonic Pachymetry for Assessment of Central Corneal Thickness
    Celebi, Ali Riza Cenk
    Mirza, G. Ertugrul
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (04): : 259 - 262
  • [5] Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method
    Thomas, Joseph
    Wang, Jianhua
    Rollins, Andrew M.
    Sturm, Julie
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 671 - 678
  • [6] A clinical comparison of central corneal thickness measurements with Optical Coherence Tomography versus ultrasonic pachymetry
    Bechmann, M
    Thiel, MJ
    Roesen, B
    Ullrich, S
    Ulbig, MW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S902 - S902
  • [7] Precision of corneal thickness measurements from reflection spectra: Comparison with Orbscan, optical coherence tomography and ultrasound pachymetry.
    Markakis, GA
    King-Smith, PE
    Roberts, CJ
    Lembach, RG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S528 - S528
  • [8] Comparison of ultrasonic pachymetry with orbscan in corneal haze
    Rana Altan-Yaycioglu
    Aysel Pelit
    Yonca Aydin Akova
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1759 - 1763
  • [9] Comparison of ultrasonic pachymetry with orbscan in corneal haze
    Altan-Yaycioglu, Rana
    Pelit, Aysel
    Akova, Yonca Aydin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) : 1759 - 1763
  • [10] Comparison of central corneal thickness measurements by ultrasound pachymetry, Orbscan, and third generation optical coherence tomography (OCT3)
    Fishman, GR
    Pons, M
    Makornwattana, M
    Seedor, J
    Liebmann, J
    Ritch, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U5 - U5