Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry Orbscan II, and optical coherence tomography

被引:96
|
作者
Haque, S [1 ]
Simpson, T [1 ]
Jones, L [1 ]
机构
[1] Univ Waterloo, Sch Optometry, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.3928/1081-597X-20060501-11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare corneal thickness measurements in individuals with keratoconus using optical coherence tomography (OCT), Orbscan II, and ultrasonic pachymetry and to measure epithelial and stromal thickness in these individuals using OCT. METHODS: Twenty individuals with keratoconus and 20 controls (without keratoconus) were enrolled. The Orbscan If was used to locate the steepest area of the cornea, which was taken to represent the cone apex. Each instrument was used to obtain four total corneal thickness measurements-from the cone apex, corneal center, mid-nasal, and mid-temporal cornea. Optical coherence tomography scans were analyzed to provide epithelial and stromal thickness readings. RESULTS: In individuals with keratoconus, mean central corneal thickness (CCT) measured by ultrasonic pachymetry Orbscan, and OCT was 494.2 +/- 50.0 mu m, 438.6 +/- 47.7 mu m, and 433.5 +/- 39.7 mu m, respectively. The central keratoconic cornea was 57.7 mu m thinner than the normal cornea (post-hoc P<.001). The cone apex was thinner than the central cornea (P<.001). Keratoconic epithelium was 48.2 +/- 5.5 mu m centrally and 42.1 +/- 4.5 mu m at the apex. Central keratoconic epithelium was 4.7 mu m thinner and central keratoconic stroma was 57.8 mu m thinner than the normal cornea (P<.001, respectively). Comparing instruments, Orbscan and OCT correlated in CCT measurement (r=0.890) and apical thickness (r=0.846). All instruments produced similar readings for mid-nasal and mid-temporal corneal thickness in participants with keratoconus (P>.05). CONCLUSIONS: Ultrasonic pachymetry produced the highest corneal thickness readings in the center and apex, compared to Orbscan 11 and OCT Centrally, the total cornea, epithelium, and stroma were thinner in individuals with keratoconus than in normal individuals.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [21] Comparison of corneal pachymetry using ultrasound and Orbscan II
    Fakhry, MA
    Artola, A
    Belda, JL
    Ayala, MJ
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 248 - 252
  • [22] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885
  • [23] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (06):
  • [24] Central corneal thickness measurements using Orbscan II scanning slit topography, noncontact specular microscopy, and ultrasonic pachymetry in eyes with keratoconus
    Kawana, K
    Miyata, K
    Tokunaga, T
    Kiuchi, T
    Hiraoka, T
    Oshika, T
    CORNEA, 2005, 24 (08) : 967 - 971
  • [25] Comparison of Orbscan and Ultrasound pachymetry in the measurement of central corneal thickness
    S W Radford
    R Lim
    J F Salmon
    Eye, 2004, 18 : 434 - 436
  • [26] Comparison of Orbscan and Ultrasound pachymetry in the measurement of central corneal thickness
    Radford, SW
    Lim, R
    Salmon, JF
    EYE, 2004, 18 (04) : 434 - 436
  • [27] Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    Bechmann, M
    Thiel, MJ
    Neubauer, AS
    Ullrich, S
    Ludwig, K
    Kenyon, KR
    Ulbig, MW
    CORNEA, 2001, 20 (01) : 50 - 54
  • [28] A comparative analysis of corneal thickness by Optical Coherence Tomography and pachymetry.
    Malkani, SM
    Panthagani, P
    Chalam, KV
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S898 - S898
  • [29] Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    Wong, ACM
    Wong, CC
    Yuen, NSY
    Hui, SP
    EYE, 2002, 16 (06) : 715 - 721
  • [30] Correlational study of central corneal thickness measurements on Hong Kong Chinese using optical coherence tomography, Orbscan and ultrasound pachymetry
    A C-M Wong
    C-C Wong
    N S-Y Yuen
    S-P Hui
    Eye, 2002, 16 : 715 - 721