Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry Orbscan II, and optical coherence tomography

被引:96
|
作者
Haque, S [1 ]
Simpson, T [1 ]
Jones, L [1 ]
机构
[1] Univ Waterloo, Sch Optometry, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.3928/1081-597X-20060501-11
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare corneal thickness measurements in individuals with keratoconus using optical coherence tomography (OCT), Orbscan II, and ultrasonic pachymetry and to measure epithelial and stromal thickness in these individuals using OCT. METHODS: Twenty individuals with keratoconus and 20 controls (without keratoconus) were enrolled. The Orbscan If was used to locate the steepest area of the cornea, which was taken to represent the cone apex. Each instrument was used to obtain four total corneal thickness measurements-from the cone apex, corneal center, mid-nasal, and mid-temporal cornea. Optical coherence tomography scans were analyzed to provide epithelial and stromal thickness readings. RESULTS: In individuals with keratoconus, mean central corneal thickness (CCT) measured by ultrasonic pachymetry Orbscan, and OCT was 494.2 +/- 50.0 mu m, 438.6 +/- 47.7 mu m, and 433.5 +/- 39.7 mu m, respectively. The central keratoconic cornea was 57.7 mu m thinner than the normal cornea (post-hoc P<.001). The cone apex was thinner than the central cornea (P<.001). Keratoconic epithelium was 48.2 +/- 5.5 mu m centrally and 42.1 +/- 4.5 mu m at the apex. Central keratoconic epithelium was 4.7 mu m thinner and central keratoconic stroma was 57.8 mu m thinner than the normal cornea (P<.001, respectively). Comparing instruments, Orbscan and OCT correlated in CCT measurement (r=0.890) and apical thickness (r=0.846). All instruments produced similar readings for mid-nasal and mid-temporal corneal thickness in participants with keratoconus (P>.05). CONCLUSIONS: Ultrasonic pachymetry produced the highest corneal thickness readings in the center and apex, compared to Orbscan 11 and OCT Centrally, the total cornea, epithelium, and stroma were thinner in individuals with keratoconus than in normal individuals.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [11] Comparison of central corneal thickness: ultrasound pachymetry versus slit-lamp optical coherence tomography, specular microscopy, and Orbscan
    Khaja, Wassia A.
    Grover, Sandeep
    Kelmenson, Amy T.
    Ferguson, Lee R.
    Sambhav, Kumar
    Chalam, Kakarla V.
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1065 - 1070
  • [12] Comparison of central corneal thickness measurements by ultrasound pachymetry, Konan noncontact optical pachymetry, and Orbscan pachymetry
    Christensen, Amarilda
    Narvaez, Julio
    Zimmerman, Grenith
    CORNEA, 2008, 27 (08) : 862 - 865
  • [13] Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    Yaylali, V
    Kaufman, SC
    Thompson, HW
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09): : 1345 - 1350
  • [14] Corneal epithelial thickness analysis of forme fruste keratoconus with optical coherence tomography
    Xiao-Long Yang
    Yun Wang
    Bao-Gen Luo
    Yue Xu
    Xiao-Feng Zhang
    International Journal of Ophthalmology, 2021, 14 (01) : 89 - 96
  • [15] Corneal epithelial thickness analysis of forme fruste keratoconus with optical coherence tomography
    Yang, Xiao-Long
    Wang, Yun
    Luo, Bao-Gen
    Xu, Yue
    Zhang, Xiao-Feng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (01) : 89 - 96
  • [16] Agreement among 3 methods to measure corneal thickness: Ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography
    Li, Emmy Y. M.
    Mohamed, Shaheeda
    Leung, Christopher K. S.
    Rao, Srinivas K.
    Cheng, Arthur C. K.
    Cheung, Carol Y. L.
    Lam, Dennis S. C.
    OPHTHALMOLOGY, 2007, 114 (10) : 1842 - 1847
  • [17] Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease
    Hoehn, A. L.
    Thomasy, S. M.
    Kass, P. H.
    Horikawa, T.
    Samuel, M.
    Shull, O. R.
    Stewart, K. A.
    Murphy, C. J.
    VETERINARY JOURNAL, 2018, 242 : 59 - 66
  • [18] Comparison of central corneal thickness measurements obtained by ultrasonic pachymetry and the Orbscan Topography System
    Hsu, J
    Grossman, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S902 - S902
  • [19] Accuracy of RTVue Optical Coherence Tomography, Pentacam, and Ultrasonic Pachymetry for the Measurement of Central Corneal Thickness
    Nam, Sang Min
    Im, Chan Young
    Lee, Hyung Keun
    Kim, Eung Kweon
    Kim, Tae-im
    Seo, Kyoung Yul
    OPHTHALMOLOGY, 2010, 117 (11) : 2096 - 2103
  • [20] Comparison between central corneal thickness measurements by ultrasound pachymetry and optical coherence tomography
    Leung, Dexter Y. L.
    Lam, Douglas K. T.
    Yeung, Barry Y. M.
    Lam, Dennis S. C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08): : 751 - 754