Design-Based stereology and binary image histomorphometry in nerve assessment

被引:16
|
作者
Hunter, Daniel A. [1 ]
Pan, Deng [1 ]
Wood, Matthew D. [1 ]
Snyder-Warwick, Alison K. [1 ]
Moore, Amy M. [2 ]
Feldman, Eva L. [3 ]
Mackinnon, Susan E. [1 ]
Brenner, Michael J. [4 ]
机构
[1] Washington Univ, Dept Surg, Div Plast & Reconstruct Surg, Sch Med, St Louis, MO 63110 USA
[2] Ohio State Univ, Wexner Med Ctr, Dept Plast & Reconstruct Surg, 915 Olentangy River Rd,Suite 2100, Columbus, OH 43212 USA
[3] Univ Michigan, Dept Neurol, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Otolaryngol Head & Neck Surg, Ann Arbor, MI 48109 USA
关键词
Nerve injury; Design-Based stereology; Quantitative histomorphometry; Binary image analysis; Nerve regeneration; Electron microscopy; FUNCTIONAL RECOVERY; REGENERATION; MORPHOMETRY; CRUSH; RATS;
D O I
10.1016/j.jneumeth.2020.108635
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Stereology and histomorphometry are widely used by investigators to quantify nerve characteristics in normal and pathological states, including nerve injury and regeneration. While these methods of analysis are complementary, no study to date has systematically compared both approaches in peripheral nerve. This study investigated the reliability of design-based stereology versus semi-automated binary imaging histomorphometry for assessing healthy peripheral nerve characteristics. New Method: Stereological analysis was compared to histomorphometry with binary image analysis on uninjured sciatic nerves to determine nerve fiber number, nerve area, neural density, and fiber distribution. Results: Sciatic nerves were harvested from 6 male Lewis rats, aged 8-12 weeks for comprehensive analysis of 6 nerve specimens. From each animal, sciatic nerve specimens were fixed, stained, and sectioned for analysis by light and electron microscopy. Both histomorphometry and stereological peripheral nerve analyses were performed on all specimens by two blinded and independent investigators who quantified nerve fiber count, fiber width, density, and related distribution parameters. Comparison with existing methods: Histomorphometry and stereological analysis provided similar outcomes in nerve fiber number and total nerve area. However, the light microscopy, but not electron microscopy, stereological analysis yielded higher nerve fiber area compared to histomorphometry or manual measurement. Conclusion: Both methods measure similar fiber number and overall nerve fiber area; however, stereology with light microscopy quantified higher fiber area. Histomorphometry optimizes throughput and comprehensive analysis but requires user thresholding.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Design-based mathematics workshops
    Xiao, Lu
    Namukasa, Immaculate
    Zhang, Yibing
    NEW LIBRARY WORLD, 2016, 117 (3-4) : 138 - 157
  • [42] Design-based research for LIS
    Bowler, Leanne
    Large, Andrew
    LIBRARY & INFORMATION SCIENCE RESEARCH, 2008, 30 (01) : 39 - 46
  • [43] A review of design-based research
    Tseng, Sheng-Shiang
    Yang, Shih-Hsien
    Yeh, Hui-Chin
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ADVANCED LEARNING TECHNOLOGIES (ICALT), 2016, : 506 - 507
  • [44] Design-based medical training
    Lovquist, Erik
    Kulcsar, Zsuzsanna
    IEEE PERVASIVE COMPUTING, 2007, 6 (02) : 61 - 61
  • [45] A design-based trial of Lesson Study for assessment purposes: evaluating a new classroom based dynamic assessment approach
    Norwich, Brahm
    Ylonen, Annamari
    EUROPEAN JOURNAL OF SPECIAL NEEDS EDUCATION, 2015, 30 (02) : 253 - 273
  • [46] Practical implications of design-based sampling inference for thematic map accuracy assessment
    Stehman, SV
    REMOTE SENSING OF ENVIRONMENT, 2000, 72 (01) : 35 - 45
  • [47] Design-based system performance assessment of a combined power and freshwater cogeneration system
    Elfizon, Elfizon
    Nunez Alvarez, Jose Ricardo
    Chammam, Abdeljelil
    Al-Kharsan, Ibrahim H.
    Jweeg, Muhsin J.
    Yanez-Moretta, Patricio
    Alayi, Reza
    Khan, Imran
    Byun, Yung-Cheol
    Madsen, Dag oivind
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [48] 3D image-based stereology
    Adachi, Yoshitaka
    Ojima, Mayumi
    Sato, Naoko
    Wang, Yuan Tsung
    THERMEC 2011, PTS 1-4, 2012, 706-709 : 2687 - +
  • [49] Binary image operator design based on stacked generalization
    Hirata, NST
    SIBGRAPI 2005: XVIII BRAZILIAN SYMPOSIUM ON COMPUTER GRAPHICS AND IMAGE PROCESSING, CONFERENCE PROCEEDINGS, 2005, : 63 - 70
  • [50] Application of design-based stereology for estimation of absolute volume and surface area of the articular and calcified cartilage compartments of undecalcified human femoral heads
    Hartlev, L. B.
    Nyengaard, J. R.
    Thomsen, J. S.
    Boel, L. W. T.
    Stengaard-Pedersen, K.
    Hauge, E. -M.
    JOURNAL OF MICROSCOPY, 2013, 251 (02) : 133 - 143