Design-Based stereology and binary image histomorphometry in nerve assessment

被引:16
|
作者
Hunter, Daniel A. [1 ]
Pan, Deng [1 ]
Wood, Matthew D. [1 ]
Snyder-Warwick, Alison K. [1 ]
Moore, Amy M. [2 ]
Feldman, Eva L. [3 ]
Mackinnon, Susan E. [1 ]
Brenner, Michael J. [4 ]
机构
[1] Washington Univ, Dept Surg, Div Plast & Reconstruct Surg, Sch Med, St Louis, MO 63110 USA
[2] Ohio State Univ, Wexner Med Ctr, Dept Plast & Reconstruct Surg, 915 Olentangy River Rd,Suite 2100, Columbus, OH 43212 USA
[3] Univ Michigan, Dept Neurol, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Otolaryngol Head & Neck Surg, Ann Arbor, MI 48109 USA
关键词
Nerve injury; Design-Based stereology; Quantitative histomorphometry; Binary image analysis; Nerve regeneration; Electron microscopy; FUNCTIONAL RECOVERY; REGENERATION; MORPHOMETRY; CRUSH; RATS;
D O I
10.1016/j.jneumeth.2020.108635
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Stereology and histomorphometry are widely used by investigators to quantify nerve characteristics in normal and pathological states, including nerve injury and regeneration. While these methods of analysis are complementary, no study to date has systematically compared both approaches in peripheral nerve. This study investigated the reliability of design-based stereology versus semi-automated binary imaging histomorphometry for assessing healthy peripheral nerve characteristics. New Method: Stereological analysis was compared to histomorphometry with binary image analysis on uninjured sciatic nerves to determine nerve fiber number, nerve area, neural density, and fiber distribution. Results: Sciatic nerves were harvested from 6 male Lewis rats, aged 8-12 weeks for comprehensive analysis of 6 nerve specimens. From each animal, sciatic nerve specimens were fixed, stained, and sectioned for analysis by light and electron microscopy. Both histomorphometry and stereological peripheral nerve analyses were performed on all specimens by two blinded and independent investigators who quantified nerve fiber count, fiber width, density, and related distribution parameters. Comparison with existing methods: Histomorphometry and stereological analysis provided similar outcomes in nerve fiber number and total nerve area. However, the light microscopy, but not electron microscopy, stereological analysis yielded higher nerve fiber area compared to histomorphometry or manual measurement. Conclusion: Both methods measure similar fiber number and overall nerve fiber area; however, stereology with light microscopy quantified higher fiber area. Histomorphometry optimizes throughput and comprehensive analysis but requires user thresholding.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Using virtual microscopy for the development of sampling strategies in quantitative histology and design-based stereology
    Kolinko, Yaroslav
    Maleckova, Anna
    Kochova, Petra
    Grajciarova, Martina
    Blassova, Tereza
    Kural, Tomas
    Trailin, Andriy
    Cervenkova, Lenka
    Havrankova, Jirina
    Vistejnova, Lucie
    Tonarova, Pavla
    Moulisova, Vladimira
    Jirik, Miroslav
    Zavadakova, Anna
    Tichanek, Filip
    Liska, Vaclav
    Kralickova, Milena
    Witter, Kirsti
    Tonar, Zbynek
    ANATOMIA HISTOLOGIA EMBRYOLOGIA, 2022, 51 (01) : 3 - 22
  • [22] The use of design-based stereology to evaluate volumes and numbers in the liver: a review with practical guidelines
    Marcos, Ricardo
    Monteiro, Rogerio A. F.
    Rocha, Eduardo
    JOURNAL OF ANATOMY, 2012, 220 (04) : 303 - 317
  • [23] THREE - DIMENSIONAL ASSESSMENT OF SARCOMAS IN CATS, USING COMPUTERISED-TOMOGRAPHY COUPLED WITH DESIGN-BASED STEREOLOGY-A CASE REPORT
    Carneiro, C. S.
    Ribeiro, A. A. C. M.
    Costa, T. A.
    Gomes, S. P.
    Oliveira, F. R.
    Fonseca Pinto, A. C. B. C.
    Matera, J. M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (02) : 219 - 219
  • [24] Design-based stereology to quantify structural properties of artificial and natural snow using thin sections
    Riche, F.
    Schneebeli, M.
    Tschanz, S. A.
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2012, 79-80 : 67 - 74
  • [25] Total Number Is Important: Using the Disector Method in Design-Based Stereology to Understand the Structure of the Rodent Brain
    Napper, Ruth M. A.
    FRONTIERS IN NEUROANATOMY, 2018, 12
  • [26] Three-dimensional morphometry of kidney in New Zealand rabbit using unbiased design-based stereology
    Sadeghinezhad, Javad
    Lazzarini, Giulia
    Bojarzadeh, Hadis
    Gatta, Alessandra
    Rezai, Sobhan
    Pirone, Andrea
    Miragliotta, Vincenzo
    MICROSCOPY RESEARCH AND TECHNIQUE, 2024, 87 (09) : 2053 - 2062
  • [27] Building waste assessment score: design-based tool
    Ekanayake, LL
    Ofori, G
    BUILDING AND ENVIRONMENT, 2004, 39 (07) : 851 - 861
  • [28] Binary imaging analysis for comprehensive quantitative histomorphometry of peripheral nerve
    Hunter, Daniel A.
    Moradzadeh, Arash
    Whitlock, Elizabeth L.
    Brenner, Michael J.
    Myckatyn, Terence A.
    Wei, Cindy H.
    Tung, Thomas H. H.
    Mackinnon, Susan E.
    JOURNAL OF NEUROSCIENCE METHODS, 2007, 166 (01) : 116 - 124
  • [29] The hepatocytes of the brown trout (Salmo trutta f. fario):: A quantitative study using design-based stereology
    Rocha, E
    Monteiro, RAF
    Oliveira, MH
    Silva, MW
    HISTOLOGY AND HISTOPATHOLOGY, 2001, 16 (02) : 423 - 437
  • [30] Postnatal cerebellar granule cells of the white rat (Rattus norvegicus):: a quantitative study, using design-based stereology
    Monteiro, RAF
    Henrique, RMF
    Oliveira, MH
    Silva, MW
    Rocha, E
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2005, 187 (02) : 161 - 173