BackgroundThe aim of this study was to determine the role of multichannel intraluminal impedance-pH (pH-MII) monitoring in the diagnosis of gastro-esophageal reflux disease (GERD) in children who presented with gastrointestinal (GI) symptoms in comparison with the results of pH-metry alone and endoscopy. MethodsAll children who underwent pH-MII monitoring due to GI symptoms, suggestive of GERD, from October 2013 to October 2015 in Children's Hospital Zagreb, were retrospectively enrolled in the study. The cohort was divided into three groups according to age - group 1: children <1 year of age; group 2: 1-9 years of age; and group 3: 9 years of age. Key ResultsOne hundred thirty-three patients met our inclusion criteria (73 female/60 male; mean age 9.2 years [0.19-18.0]). Gastro-esophageal reflux disease was determined in 44 of 133 patients (33.1%) by pH-MII and only in 21 of 133 patients (15.8%) by pH-metry alone. Endoscopy was performed in 77 (57.9%) children and esophagitis was found in 32/77 (41.6%). The finding of esophagitis significantly correlated with the number of total reflux episodes (coef. 0.42, p < 0.001), acidic (coef. 0.26, p = 0.02), weakly acidic (coef. 0.3, p = 0.008) and non-acidic (coef. 0.26, p = 0.02) reflux episodes detected by pH-MII; but, no correlation was found to reflux episodes detected by pH-metry alone (coef. 0.21, p = 0.07). Conclusions & InferencesCompared with pH-metry alone, pH-MII performed significantly better in the detection of GERD in all age groups. On the basis of our data, pH-MII had a strong correlation with endoscopically confirmed esophagitis.
引用
收藏
页码:1488 / 1493
页数:6
相关论文
共 50 条
  • [41] Does hypopharyngeal–esophageal multichannel intraluminal impedance–pH monitoring for the diagnosis of laryngopharyngeal reflux have to be 24 h?
    Jinhong Zhang
    Xiaoyu Wang
    Jiasen Wang
    Jing Zhao
    Chun Zhang
    Zhi Liu
    Jinrang Li
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 5323 - 5329
  • [42] Role of Hiatal Hernia in Esophageal Acid Clearance as Measured by Multichannel Intraluminal Impedance-pH Monitoring and pH, in Patients With Non-Erosive Reflux Disease
    Moran, Edgardo Suarez
    Galomo, Carlos Cerda
    Silva, Francisca Martinez
    Zuniga, Aurora E. Seralde
    Crespo, Yasmin
    Soto-Perez, Julio-Cesar
    Vargas, Jose-Antonio
    GASTROENTEROLOGY, 2012, 142 (05) : S424 - S425
  • [43] The role of 24 h pH-recording in pediatric otolaryngologic gastro-esophageal reflux disease
    van Den Abbeele, T
    Couloigner, V
    Faure, C
    Narcy, P
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2003, 67 : S95 - S100
  • [44] Evaluation of esophageal motility and reflux in children treated for congenital diaphragmatic hernia with the use of combined multichannel intraluminal impedance and pH monitoring
    Di Pace, Maria Rita
    Caruso, Anna Maria
    Farina, Fabiana
    Casuccio, Alessandra
    Cimador, Marcello
    De Grazia, Enrico
    JOURNAL OF PEDIATRIC SURGERY, 2011, 46 (10) : 1881 - 1886
  • [45] The utility of multichannel intraluminal impedance-pH testing in tailoring the management of paediatric gastro-oesophageal reflux disease
    Gunasagaran, Hema Lattha
    Varjavandi, Vincent
    Lemberg, Daniel A.
    Ooi, Chee Y.
    Gupta, Nitin
    Krishnan, Usha
    ACTA PAEDIATRICA, 2020, 109 (12) : 2799 - 2807
  • [46] Detection of gastroesophageal reflux in children with cerebral palsy using combined multichannel intraluminal impedance-ph procedure
    Caltepe, Gonul
    Yuce, Ozlem
    Comba, Atakan
    Ozyurek, Hamit
    Kalayci, Ayhan Gazi
    Tasdemir, Haydar Ali
    TURKISH JOURNAL OF PEDIATRICS, 2016, 58 (05) : 524 - 531
  • [47] How Useful the Combined Impedance-pH Monitoring Is for Evaluation of Refractory Reflux Symptoms?
    Cho, Yu Kyung
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2011, 17 (03) : 327 - 328
  • [48] The Role of Combined Multichannel Intraluminal Impedance-pH Monitoring in Infants with Brief, Resolved, Unexplained Events
    Pavic, Ivan
    Navratil, Marta
    Bosanac, Maja
    Fures, Jadranka Sekelj
    Jurekovic, Irena Ivkovic
    Hojsak, Iva
    PEDIATRIC GASTROENTEROLOGY HEPATOLOGY & NUTRITION, 2021, 24 (03) : 256 - 264
  • [49] A 24-hour ambulatory simultaneous multichannel intraluminal impedance-pH monitoring in patients with doubtful laryngopharyngeal reflux
    Park, M. -I.
    Kim, S. -E.
    Kim, H. -H.
    Park, S. -J.
    Moon, W.
    Choi, S. -R.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 : 92 - 93
  • [50] GASTROESOPHAGEAL REFLUX DISEASE IN INFANT: RELATIONSHIP BETWEEN MULTICHANNEL INTRALUMINAL IMPEDANCE-PH MONITORING AND CLINICAL OUTCOME
    Cresi, F.
    Locatelli, E.
    Marinaccio, C.
    Grasso, G.
    Castagno, E.
    Silvestro, L.
    PEDIATRIC RESEARCH, 2010, 68 : 142 - 142