The role of combined 24-h multichannel intraluminal impedance-pH monitoring in the evaluation of children with gastrointestinal symptoms suggesting gastro-esophageal reflux disease

被引:19
|
作者
Hojsak, I. [1 ]
Ivkovic, L. [1 ]
Trbojevic, T. [1 ]
Pavic, I. [2 ]
Jadresin, O. [1 ]
Misak, Z. [1 ]
Kolacek, S. [1 ]
机构
[1] Childrens Hosp Zagreb, Referral Ctr Pediat Gastroenterol & Nutr, Klaiceva 16, Zagreb 10000, Croatia
[2] Childrens Hosp Zagreb, Dept Pulmonol Allergol & Immunol, Zagreb, Croatia
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2016年 / 28卷 / 10期
关键词
children; endoscopy; gastro-esophageal reflux; multichannel intraluminal impedance; pH-metry; ESOPHAGITIS;
D O I
10.1111/nmo.12846
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BackgroundThe aim of this study was to determine the role of multichannel intraluminal impedance-pH (pH-MII) monitoring in the diagnosis of gastro-esophageal reflux disease (GERD) in children who presented with gastrointestinal (GI) symptoms in comparison with the results of pH-metry alone and endoscopy. MethodsAll children who underwent pH-MII monitoring due to GI symptoms, suggestive of GERD, from October 2013 to October 2015 in Children's Hospital Zagreb, were retrospectively enrolled in the study. The cohort was divided into three groups according to age - group 1: children <1 year of age; group 2: 1-9 years of age; and group 3: 9 years of age. Key ResultsOne hundred thirty-three patients met our inclusion criteria (73 female/60 male; mean age 9.2 years [0.19-18.0]). Gastro-esophageal reflux disease was determined in 44 of 133 patients (33.1%) by pH-MII and only in 21 of 133 patients (15.8%) by pH-metry alone. Endoscopy was performed in 77 (57.9%) children and esophagitis was found in 32/77 (41.6%). The finding of esophagitis significantly correlated with the number of total reflux episodes (coef. 0.42, p < 0.001), acidic (coef. 0.26, p = 0.02), weakly acidic (coef. 0.3, p = 0.008) and non-acidic (coef. 0.26, p = 0.02) reflux episodes detected by pH-MII; but, no correlation was found to reflux episodes detected by pH-metry alone (coef. 0.21, p = 0.07). Conclusions & InferencesCompared with pH-metry alone, pH-MII performed significantly better in the detection of GERD in all age groups. On the basis of our data, pH-MII had a strong correlation with endoscopically confirmed esophagitis.
引用
收藏
页码:1488 / 1493
页数:6
相关论文
共 50 条
  • [21] Evaluation of esophageal motility and reflux in children treated for esophageal atresia with the use of combined multichannel intraluminal impedance and pH monitoring
    Di Pace, Maria Rita
    Caruso, Anna Maria
    Catalano, Pieralba
    Casuccio, Alessandra
    Cimador, Marcello
    De Grazia, Enrico
    JOURNAL OF PEDIATRIC SURGERY, 2011, 46 (03) : 443 - 451
  • [22] Evaluation of Gastroesophageal Reflux by Combined Multichannel Intraluminal Impedance and pH Monitoring and Esophageal Motility Patterns in Children with Esophageal Atresia
    Tong, Stanley
    Mallitt, Kylie-ann
    Krishnan, Usha
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2016, 26 (04) : 322 - 331
  • [23] Is combined multichannel intraluminal impedance-ph monitoring superior to the conventional 24 hour pH meter in the evaluation of patients with laryngorespiratory symptoms suspected to be due to gastroesophageal reflux disease (GERD)?
    Ang, D.
    Ang, T. L.
    Hsu, P. P.
    Tee, A.
    Poh, C. H.
    Teo, E. K.
    Fock, K. M.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 : 201 - 202
  • [24] The importance of 24-h hypopharyngeal-esophageal impedance-pH monitoring for the treatment of laryngopharyngeal reflux
    Baudouin, Robin
    Calvo-Henriquez, Christian
    Mayo-Yanez, Miguel
    Iannella, Giannicola
    Maniaci, Antonino
    Lechien, Jerome R.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5481 - 5482
  • [25] Esophageal 24hr ph-monitoring and multichannel intraluminal impedance for the diagnosis of gastroesophageal reflux and evaluation of related symptoms in children
    Magista, A.
    Bucci, N.
    Leone, G.
    Fico, S.
    Castellaneta, S.
    De Canio, A.
    Boscarelli, G.
    Mappa, L.
    Moramarco, F.
    Villirillo, A.
    Cavallo, L.
    Francavilla, R.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2007, 44 : 280 - 280
  • [26] Esophageal combined multichannel intraluminal impedance-pH monitoring and its clinical value in the diagnosis of various types of gastroesophageal reflux disease
    Morozov, S.
    Kukushkina, M.
    Isakov, V.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 : 96 - 96
  • [27] Association between 24-hour combined multichannel intraluminal impedance-pH monitoring and symptoms or quality of life in patients with laryngopharyngeal reflux
    Kim, S. I.
    Kwon, O. E.
    Na, S. Y.
    Lee, Y. C.
    Park, J. M.
    Eun, Y. G.
    CLINICAL OTOLARYNGOLOGY, 2017, 42 (03) : 584 - 591
  • [28] Combined multichannel intraluminal impedance and pH monitoring is helpful in managing children with suspected gastro-oesophageal reflux disease
    Rossi, Paolo
    Isoldi, Sara
    Mallardo, Saverio
    Papoff, Paola
    Rossetti, Danilo
    Dilillo, Anna
    Oliva, Salvatore
    DIGESTIVE AND LIVER DISEASE, 2018, 50 (09) : 910 - 915
  • [29] Reflux scintigraphy in gastro-esophageal reflux disease: a comparison study with 24 hour pH-impedance monitoring
    Shim, Lisa S. E.
    Ngu, Meng C.
    Yau, Yunki
    Russo, Robert
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2022, 57 (06) : 660 - 664
  • [30] In response to the importance of 24-h hypopharyngeal-esophageal impedance-pH monitoring for the treatment of laryngopharyngeal reflux
    Zhang, Jinhong
    Wang, Xiaoyu
    Wang, Jiasen
    Zhao, Jing
    Zhang, Chun
    Liu, Zhi
    Li, Jinrang
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5483 - 5484