The role of combined 24-h multichannel intraluminal impedance-pH monitoring in the evaluation of children with gastrointestinal symptoms suggesting gastro-esophageal reflux disease

被引:19
|
作者
Hojsak, I. [1 ]
Ivkovic, L. [1 ]
Trbojevic, T. [1 ]
Pavic, I. [2 ]
Jadresin, O. [1 ]
Misak, Z. [1 ]
Kolacek, S. [1 ]
机构
[1] Childrens Hosp Zagreb, Referral Ctr Pediat Gastroenterol & Nutr, Klaiceva 16, Zagreb 10000, Croatia
[2] Childrens Hosp Zagreb, Dept Pulmonol Allergol & Immunol, Zagreb, Croatia
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2016年 / 28卷 / 10期
关键词
children; endoscopy; gastro-esophageal reflux; multichannel intraluminal impedance; pH-metry; ESOPHAGITIS;
D O I
10.1111/nmo.12846
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BackgroundThe aim of this study was to determine the role of multichannel intraluminal impedance-pH (pH-MII) monitoring in the diagnosis of gastro-esophageal reflux disease (GERD) in children who presented with gastrointestinal (GI) symptoms in comparison with the results of pH-metry alone and endoscopy. MethodsAll children who underwent pH-MII monitoring due to GI symptoms, suggestive of GERD, from October 2013 to October 2015 in Children's Hospital Zagreb, were retrospectively enrolled in the study. The cohort was divided into three groups according to age - group 1: children <1 year of age; group 2: 1-9 years of age; and group 3: 9 years of age. Key ResultsOne hundred thirty-three patients met our inclusion criteria (73 female/60 male; mean age 9.2 years [0.19-18.0]). Gastro-esophageal reflux disease was determined in 44 of 133 patients (33.1%) by pH-MII and only in 21 of 133 patients (15.8%) by pH-metry alone. Endoscopy was performed in 77 (57.9%) children and esophagitis was found in 32/77 (41.6%). The finding of esophagitis significantly correlated with the number of total reflux episodes (coef. 0.42, p < 0.001), acidic (coef. 0.26, p = 0.02), weakly acidic (coef. 0.3, p = 0.008) and non-acidic (coef. 0.26, p = 0.02) reflux episodes detected by pH-MII; but, no correlation was found to reflux episodes detected by pH-metry alone (coef. 0.21, p = 0.07). Conclusions & InferencesCompared with pH-metry alone, pH-MII performed significantly better in the detection of GERD in all age groups. On the basis of our data, pH-MII had a strong correlation with endoscopically confirmed esophagitis.
引用
收藏
页码:1488 / 1493
页数:6
相关论文
共 50 条
  • [31] Standard values of 24-h multichannel intraluminal impedance–pH monitoring for the Japanese
    Fumiaki Yano
    Nobuo Omura
    Kazuto Tsuboi
    Masato Hoshino
    Se Ryung Yamamoto
    Shunsuke Akimoto
    Takahiro Masuda
    Norio Mitsumori
    Hideyuki Kashiwagi
    Katsuhiko Yanaga
    Esophagus, 2017, 14 : 91 - 96
  • [32] Combined Multichannel Intraluminal Impedance and pH Esophageal Testing Versus pH Alone for Diagnosing Gastro-Esophageal Reflux: A Study On Italian Patients Off Therapy
    Corsetti, Maura
    Vailati, Cristian
    Passaretti, Sandro M.
    Notaristefano, Chiara
    Testoni, Pier A.
    GASTROENTEROLOGY, 2009, 136 (05) : A85 - A85
  • [33] Evaluation of gastro-oesophageal reflux disease in wheezy infants using 24-h oesophageal combined impedance and pH monitoring
    Abdallah, Ahmed
    El-Desoky, Tarek
    Fathi, Khalid
    Elkashef, Wagdi Fawzi
    Zaki, Ahmed
    ARAB JOURNAL OF GASTROENTEROLOGY, 2017, 18 (02) : 68 - 73
  • [34] Combined multichannel intraluminal impedance-pH monitoring to select patients with persistent gastro-oesophageal reflux for laparoscopic Nissen fundoplication
    Mainie, I.
    Tutuian, R.
    Agrawal, A.
    Adams, D.
    Castell, D. O.
    BRITISH JOURNAL OF SURGERY, 2006, 93 (12) : 1483 - 1487
  • [35] 24-hour ambulatory esophageal multichannel intraluminal impedance-pH in healthy European subjects: Normal values for acid, weakly acidic and weakly alkaline gastro-esophageal reflux.
    Zerbib, F
    des Varannes, SB
    Roman, S
    Pouderoux, P
    Verin, E
    Artigue, F
    Chaput, U
    Caillol, F
    Mion, F
    Galmiche, JP
    Sifrim, D
    GASTROENTEROLOGY, 2005, 128 (04) : A396 - A396
  • [36] Is Combined Multichannel Intraluminal Impedance-pH Monitoring Superior to the Conventional 24 Hour pH Meter in the Evaluation of Patients With Laryngorespiratory Symptoms Suspected to Be Due to Gastroesophageal Reflux Disease: A Study in Asian Patients
    Ang, Daphne
    Ang, Tiing Leong
    Poh, Choo Hean
    Ong, Jeannie
    Tan, Jessica
    Teo, Eng Kiong
    Fock, Kwong Ming
    GASTROENTEROLOGY, 2011, 140 (05) : S251 - S251
  • [37] The role of combined multichannel intraluminal impedance and pH- monitoring in newborn with gastroesophageal reflux disease
    Cresi, Francesco
    Locatelli, Emanuela
    REVIEWS IN HEALTH CARE, 2010, 1 (01) : 35 - 52
  • [38] Intense Gastro-Esophageal Reflux May Influence the Localization of Barrett's Adenocarcinoma: Measured by 24-h pH-Impedance Monitoring
    Saito, Masahiro
    Koike, Tomoyuki
    Kikuchi, Hiroki
    Norita, Kazuaki
    Nakagawa, Kenichirou
    Kanno, Takeshi
    Kusaka, Gen
    Kondo, Yutaka
    Hatta, Waku
    Ara, Nobuyuki
    Asanuma, Kiyotaka
    Uno, Kaname
    Asano, Naoki
    Imatani, Akira
    Iijima, Katsunori
    Shimosegawa, Tooru
    GASTROENTEROLOGY, 2016, 150 (04) : S483 - S483
  • [39] CORRELATION OF GASTROESOPHAGEAL REFLUX DISEASE ASSESSMENT SYMPTOM QUESTIONNAIRE SCORE TO ESOPHAGEAL MULTICHANNEL INTRALUMINAL IMPEDANCE-PH MEASUREMENTS IN CHILDREN
    Prachuapthunyachart, S.
    Gremse, D.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (02) : 654 - 654
  • [40] Endoscopic finding and multichannel intraluminal impedance-pH monitoring of gastroesofageal reflux disease in outpatient clinic
    Syam, Ari Fahrial
    Setiawan, Hardianto
    Shatri, Hamzah
    Makmun, Dadang
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 : 19 - 19