The role of combined 24-h multichannel intraluminal impedance-pH monitoring in the evaluation of children with gastrointestinal symptoms suggesting gastro-esophageal reflux disease

被引:19
|
作者
Hojsak, I. [1 ]
Ivkovic, L. [1 ]
Trbojevic, T. [1 ]
Pavic, I. [2 ]
Jadresin, O. [1 ]
Misak, Z. [1 ]
Kolacek, S. [1 ]
机构
[1] Childrens Hosp Zagreb, Referral Ctr Pediat Gastroenterol & Nutr, Klaiceva 16, Zagreb 10000, Croatia
[2] Childrens Hosp Zagreb, Dept Pulmonol Allergol & Immunol, Zagreb, Croatia
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2016年 / 28卷 / 10期
关键词
children; endoscopy; gastro-esophageal reflux; multichannel intraluminal impedance; pH-metry; ESOPHAGITIS;
D O I
10.1111/nmo.12846
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BackgroundThe aim of this study was to determine the role of multichannel intraluminal impedance-pH (pH-MII) monitoring in the diagnosis of gastro-esophageal reflux disease (GERD) in children who presented with gastrointestinal (GI) symptoms in comparison with the results of pH-metry alone and endoscopy. MethodsAll children who underwent pH-MII monitoring due to GI symptoms, suggestive of GERD, from October 2013 to October 2015 in Children's Hospital Zagreb, were retrospectively enrolled in the study. The cohort was divided into three groups according to age - group 1: children <1 year of age; group 2: 1-9 years of age; and group 3: 9 years of age. Key ResultsOne hundred thirty-three patients met our inclusion criteria (73 female/60 male; mean age 9.2 years [0.19-18.0]). Gastro-esophageal reflux disease was determined in 44 of 133 patients (33.1%) by pH-MII and only in 21 of 133 patients (15.8%) by pH-metry alone. Endoscopy was performed in 77 (57.9%) children and esophagitis was found in 32/77 (41.6%). The finding of esophagitis significantly correlated with the number of total reflux episodes (coef. 0.42, p < 0.001), acidic (coef. 0.26, p = 0.02), weakly acidic (coef. 0.3, p = 0.008) and non-acidic (coef. 0.26, p = 0.02) reflux episodes detected by pH-MII; but, no correlation was found to reflux episodes detected by pH-metry alone (coef. 0.21, p = 0.07). Conclusions & InferencesCompared with pH-metry alone, pH-MII performed significantly better in the detection of GERD in all age groups. On the basis of our data, pH-MII had a strong correlation with endoscopically confirmed esophagitis.
引用
收藏
页码:1488 / 1493
页数:6
相关论文
共 50 条
  • [1] Esophageal chemical clearance is impaired in gastro-esophageal reflux disease a 24-h impedance-pH monitoring assessment
    Frazzoni, M.
    Manta, R.
    Mirante, V. G.
    Conigliaro, R.
    Frazzoni, L.
    Melotti, G.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (05): : 399 - e295
  • [2] Study on laryngopharyngeal and esophageal reflux characteristics using 24-h multichannel intraluminal impedance-pH monitoring in healthy volunteers
    Chenjie Hou
    Meixiang Chen
    Ting Chen
    Yang Yang
    Xiaolong Yang
    Zhihui Lin
    Yanling Zeng
    Liuqing Chen
    Chaofeng Liu
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 2801 - 2811
  • [3] Study on laryngopharyngeal and esophageal reflux characteristics using 24-h multichannel intraluminal impedance-pH monitoring in healthy volunteers
    Hou, Chenjie
    Chen, Meixiang
    Chen, Ting
    Yang, Yang
    Yang, Xiaolong
    Lin, Zhihui
    Zeng, Yanling
    Chen, Liuqing
    Liu, Chaofeng
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (10) : 2801 - 2811
  • [4] IMPACT OF MULTICHANNEL INTRALUMINAL IMPEDANCE-PH TESTING ON THE CLINICAL MANAGEMENT OF CHILDREN WITH GASTRO ESOPHAGEAL REFLUX DISEASE
    Gunasagaran, Hema L.
    Varjavandi, Vincent
    Lemberg, Daniel
    Ooi, Chee Y.
    Gupta, Nitin
    Krishnan, Usha
    GASTROENTEROLOGY, 2018, 154 (06) : S1071 - S1072
  • [5] Standard values of 24-h multichannel intraluminal impedance-pH monitoring for the Japanese
    Yano, Fumiaki
    Omura, Nobuo
    Tsuboi, Kazuto
    Hoshino, Masato
    Yamamoto, Se Ryung
    Akimoto, Shunsuke
    Masuda, Takahiro
    Mitsumori, Norio
    Kashiwagi, Hideyuki
    Yanaga, Katsuhiko
    ESOPHAGUS, 2017, 14 (01) : 91 - 96
  • [6] The importance of combined 24-hour multichannel intraluminal impedance-pH monitoring in the evaluation of children with suspected laryngopharyngeal reflux
    Pavic, I.
    Babic, I.
    Bogovic, J. Cepin
    Hojsak, I.
    CLINICAL OTOLARYNGOLOGY, 2017, 42 (03) : 544 - 549
  • [7] Evaluation of gastroesophageal reflux with the 24 h multichannel intraluminal impedance-ph probe in children with recurrent laryngitis
    Sabban, J. Cohen
    Bertoldi, G. Donato
    Olleta, L.
    Razzetti, J.
    Orsi, M.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2010, 22 : 42 - +
  • [8] Use of multichannel intraluminal pH-impedance monitoring to document extra esophageal manifestations of gastro-esophageal reflux
    Roman, S
    Poncet, G
    Serraj, I
    Mion, F
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2005, 29 (12): : 1303 - 1304
  • [9] 24 h combined esophageal multichannel intraluminal impedance and pH monitoring in children with chronic cough
    Gan, Yi
    Zhou, Xiaoqin
    Huang, Zhaoxuan
    Gao, Shan
    Wang, Guirong
    Gu, Li
    Zhang, Di
    Yan, Lingzhi
    Shang, Shanshan
    Shu, Junhua
    Tu, Danna
    BMC PEDIATRICS, 2024, 24 (01)
  • [10] Reflux characteristics of 113 GERD patients with abnormal 24-h multichannel intraluminal impedance-pH tests
    Nian, Yuan-yuan
    Feng, Cheng
    Jing, Fu-chun
    Wang, Xue-qin
    Zhang, Jun
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2015, 16 (09): : 805 - 810