Current sensor fault detection and reconfiguration for a Doubly Fed Induction Generator

被引:23
|
作者
Rothenhagen, Kai [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Univ Kiel, Inst Power Elect & Elect Dr, D-24143 Kiel, Germany
关键词
D O I
10.1109/PESC.2007.4342450
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensor fault detection and reconfiguration of the control loops of a Doubly-Fed Induction Generator is presented in this paper. The stator and rotor currents are measured as well as observed. During fault free operation, the measured signals are used for the voltage oriented control. In case of a current sensor fault, the faulty measurement is identified and the control is reconfigured using the observer output. Laboratory measurements prove this concept.
引用
收藏
页码:2732 / 2738
页数:7
相关论文
共 50 条
  • [41] The fault ride through technologies for doubly fed induction generator wind turbines
    Ling, Yu
    WIND ENGINEERING, 2016, 40 (01) : 31 - 49
  • [42] Online Detection for Blade Imbalance of Doubly Fed Induction Generator Wind Turbines Based on Stator Current
    Shi, Liqin
    Qiu, Jixing
    Xu, Guodong
    Yang, Jing
    Wang, Jiahua
    PROCEEDINGS OF 2017 2ND INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2017, : 428 - 433
  • [43] Reduction of Current Ripples due to Current Measurement Errors in a Doubly Fed Induction Generator
    Park, Gwi-Geun
    Hwang, Seon-Hwan
    Kim, Jang-Mok
    Lee, Kyo-Beum
    Lee, Dong-Choon
    JOURNAL OF POWER ELECTRONICS, 2010, 10 (03) : 313 - 319
  • [44] Reduction of current ripples due to current measurement errors in a doubly fed induction generator
    Kim, Young-Il
    Hwang, Seon-Hwan
    Kim, Jang-Mok
    Song, Seung-Ho
    Kim, Chan-Ki
    Choy, Young-Do
    APEC 2008: TWENTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-4, 2008, : 756 - +
  • [45] PHIL Experimentation on Fault Ride Through Behavior of Doubly Fed Induction Generator Based Wind System in the Presence of Fault Current Limiter
    Gururaj, M., V
    Padhy, Narayana Prasad
    2018 IEEMA ENGINEER INFINITE CONFERENCE (ETECHNXT), 2018,
  • [46] Fault-tolerant control for current sensors of doubly fed induction generators based on an improved fault detection method
    Li, H.
    Yang, C.
    Hu, Y. G.
    Zhao, B.
    Zhao, M.
    Chen, Z.
    MEASUREMENT, 2014, 47 : 929 - 937
  • [47] Comparison of Decoupling Structures in a Rotor Current Control of Doubly Fed Induction Generator
    Luszczyk, Tomasz
    Iwanski, Grzegorz
    2013 8TH INTERNATIONAL CONFERENCE AND EXHIBITION ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2013,
  • [48] Analysis of short circuit current of wind turbine - Doubly fed induction generator
    Li, D. D.
    2006 1st IEEE Conference on Industrial Electronics and Applications, Vols 1-3, 2006, : 920 - 924
  • [49] Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator
    Liu, Changjin
    Blaabjerg, Frede
    Chen, Wenjie
    Xu, Dehong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (07) : 3207 - 3220
  • [50] Analysis on the Characteristic of the Instantaneous Inrush Current of Brushless Doubly Fed Induction Generator
    Zhang, Debin
    Ma, Jijun
    Wang, Shengjia
    Ji, Yuhui
    Qu, Chengzhi
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2023, 38 (02) : 747 - 758