Current sensor fault detection and reconfiguration for a Doubly Fed Induction Generator

被引:23
|
作者
Rothenhagen, Kai [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Univ Kiel, Inst Power Elect & Elect Dr, D-24143 Kiel, Germany
关键词
D O I
10.1109/PESC.2007.4342450
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensor fault detection and reconfiguration of the control loops of a Doubly-Fed Induction Generator is presented in this paper. The stator and rotor currents are measured as well as observed. During fault free operation, the measured signals are used for the voltage oriented control. In case of a current sensor fault, the faulty measurement is identified and the control is reconfigured using the observer output. Laboratory measurements prove this concept.
引用
收藏
页码:2732 / 2738
页数:7
相关论文
共 50 条
  • [21] Rotor-current-based fault detection for doubly-fed induction generator using new sliding mode observer
    Yu, Wenxin
    Jiang, Dan
    Wang, Junnian
    Li, Ruiqi
    Yang, Lu
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2020, 42 (16) : 3110 - 3122
  • [22] Rotor-Current and Position Estimator for Doubly-Fed Induction Generators - Application to Sensor-Fault Detection
    Mollet, Yves
    Gyselinck, Johan
    2016 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2016,
  • [23] Open switch fault diagnosis for a doubly-fed induction generator
    Sae-Kok, W.
    Grant, D. M.
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 368 - +
  • [24] Additive and multiplicative fault diagnosis for a doubly-fed induction generator
    Boulkroune, Boulaid
    Galvez-Carrillo, Manuel
    Kinnaert, Michel
    2011 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS (CCA), 2011, : 1302 - 1308
  • [25] Detection of mixed eccentricity fault in doubly-fed induction generator based on reactive power spectrum
    Faiz, Jawad
    Moosavi, Seyed Mohammad Mahdi
    IET ELECTRIC POWER APPLICATIONS, 2017, 11 (06) : 1076 - 1084
  • [26] Sensor fault detection and isolation in doubly-fed induction generators accounting for parameter variations
    Galvez-Carrillo, Manuel
    Kinnaert, Michel
    RENEWABLE ENERGY, 2011, 36 (05) : 1447 - 1457
  • [27] Analysis and Compensation of Current Measurement Errors in a Doubly Fed Induction Generator
    Son, Yung-Deug
    Im, Won-Sang
    Park, Han-Seok
    Kim, Jang-Mok
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2014, 9 (02) : 532 - 540
  • [28] Eccentricity fault detection in brushless doubly fed induction machines
    Afshar, Mojtaba
    Abdi, Salman
    Oraee, Ashknaz
    Ebrahimi, Mohammad
    McMahon, Richard
    IET ELECTRIC POWER APPLICATIONS, 2021, 15 (07) : 916 - 930
  • [29] Stator current harmonics analysis of doubly-fed induction generator
    Wang, Zhong
    Sun, Yuanzhang
    Li, Guojie
    Li, Zhiguo
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (06): : 1 - 5
  • [30] Analysis and calculation of short circuit current of doubly fed induction generator
    Li, D. D.