Current sensor fault detection and reconfiguration for a Doubly Fed Induction Generator

被引:23
|
作者
Rothenhagen, Kai [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Univ Kiel, Inst Power Elect & Elect Dr, D-24143 Kiel, Germany
关键词
D O I
10.1109/PESC.2007.4342450
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensor fault detection and reconfiguration of the control loops of a Doubly-Fed Induction Generator is presented in this paper. The stator and rotor currents are measured as well as observed. During fault free operation, the measured signals are used for the voltage oriented control. In case of a current sensor fault, the faulty measurement is identified and the control is reconfigured using the observer output. Laboratory measurements prove this concept.
引用
收藏
页码:2732 / 2738
页数:7
相关论文
共 50 条
  • [11] Model and Performance of Current Sensor Observers for a Doubly Fed Induction Generator
    Li, Hui
    Yang, Chao
    Hu, Yaogang
    Zhao, Meng
    Zhao, Bin
    Chen, Zhe
    Liu, Shengquan
    Yang, Dong
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (10) : 1048 - 1058
  • [12] Advanced Sensor Fault Detection and Control Reconfiguration of Wind Power Plants using Doubly Fed Induction Generators
    Rothenhagen, Kai
    Fuchs, Friedrich W.
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 913 - 919
  • [13] The simulation research on the characteristic of fault current of doubly-fed induction generator
    Han, Aoyang
    Zhang, Zhe
    Yin, Xianggen
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2009, 37 (09): : 105 - 108
  • [14] Sensor fault-tolerant control for a doubly fed induction generator in a smart grid
    Conchas, Robin F.
    Sanchez, Edgar N.
    Ricalde, Luis J.
    Alvarez, Jesus G.
    Alanis, Alma Y.
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 117
  • [15] Current sensor fault diagnosis for doubly-fed wind generator control system
    Zhang, Chang-Fan
    Yan, Min
    He, Jing
    Luo, Cheng
    Xiao, Yuan-Yuan
    Information Technology Journal, 2013, 12 (18) : 4368 - 4373
  • [16] Performance of Sensor and Sensorless Doubly Fed Induction Motor (DFIM) under the Current Sensor Fault
    Singh, Arunesh Kumar
    Saxena, Abhinav
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [17] Combined Signal and Model-Based Sensor Fault Diagnosis for a Doubly Fed Induction Generator
    Boulkroune, Boulaid
    Galvez-Carrillo, Manuel
    Kinnaert, Michel
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2013, 21 (05) : 1771 - 1783
  • [18] Fault Current Contribution Analysis of Doubly Fed Induction Generator-Based Wind Turbines
    El-Naggar, Ahmed
    Erlich, Istvan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (03) : 874 - 882
  • [19] An improved fault current calculation method and protection scheme of Doubly-fed Induction Generator
    Yin, Jun
    ENERGY REPORTS, 2021, 7 : 5168 - 5174
  • [20] Short Circuit Current Calculation of Doubly Fed Induction Generator
    Mortezapour, V.
    Lesani, H.
    Abbaszadeh, A.
    2009 INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS 2009), 2009, : 128 - +