Partial Discharge-induced Degradation Characteristics of Insulating Materials of Gas-filled Power Transformers

被引:9
|
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo [1 ]
Wada, Haruhisa [2 ]
Okubo, Hitoshi [3 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Kanagawa 2308510, Japan
[2] Toshiba Co Ltd, Kawasaki Ku, Kanagawa 2100862, Japan
[3] Nagoya Univ, Dept Elect Engn & Comp Sci, Furo 4648603, Japan
关键词
Gas-filled power transformer; partial discharge (PD); polyethylene terephthalate (PET) film; Nomex (R) board; pressboard; residual impulse withstand voltage; harmful partial discharge level; insulation degradation;
D O I
10.1109/TDEI.2010.5658221
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The soundness of a transformer under an operating voltage is evaluated in partial discharge (PD) test of long-duration ac withstand voltage test. At present, the same criteria for evaluating oil-filled transformers are adopted as those for evaluating gas-filled transformers in this PD test. However, gas-filled transformers are made of different insulating materials than those for oil-filled transformers, and therefore they may have different strengths against PDs from oil-filled transformers. Therefore, it is necessary to establish PD evaluation criteria for gas-filled transformers. This paper, as the first step toward this objective, discusses the study of solid insulating materials used in gas-filled transformers in terms of the generated PD magnitudes and the degrees of damage of insulation and examines the harmful PD levels that lower the residual impulse withstand voltage. As a result, it identified the PD-induced degradation patterns of some insulating materials used in gas-filled transformers, i.e., polyethylene terephthalate (PET) films and Nomex (R) boards and evaluated the harmful PD levels based on the residual impulse withstand voltages. It was also verified that the insulations of pressboards are not degraded even by relatively large PDs.
引用
收藏
页码:1715 / 1723
页数:9
相关论文
共 50 条
  • [31] Investigating the Partial Discharge Electromagnetic Wave Propagation in Power Transformers Considering Active Part Characteristics
    Mirzaei, H. R.
    Akbari, A.
    Zanjani, M.
    Gockenbach, E.
    Borsi, H.
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 442 - 445
  • [32] Study on the characteristics of elongation at break and tensile strength of photovoltaic insulating backsheets subjected to partial discharge degradation
    Wang, Qian
    Sun, Jinge
    Li, Tianhao
    Xiao, Peng
    AIP ADVANCES, 2021, 11 (04)
  • [33] Analysis for insulating degradation characteristics with aging time for oil-filled transformers and/or correlation between using linear regression method
    Lee, Seung-Min
    Transactions of the Korean Institute of Electrical Engineers, 2010, 59 (04): : 693 - 699
  • [34] High temperature PD degradation characteristics in bulk and interfaces of insulating materials for power cables
    Maruyama, A
    Komori, F
    Suzuoki, Y
    Okamoto, T
    Nagata, T
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 264 - 267
  • [35] Characteristics of the Partial Discharge-induced Current along Epoxy resin film under Superimposed AC-DC Voltage
    Zhuang, Tianxin
    Gao, Xuze
    Ren, Ming
    Wang, Siyun
    Huang, Junkai
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 469 - 472
  • [36] A Step Forward in the Characterization of the Partial Discharge Phenomenon and the Degradation of Insulating Materials Through Nonlinear Analysis of Time Series
    Barbieri, Luca
    Villa, Andrea
    Malgesini, Roberto
    IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (04) : 14 - 21
  • [37] Dielectric Properties, Partial Discharge Properties, and Dissolved Gas Analysis of Ricinnus Oils as Biodegradable Liquid Insulating Materials
    Khayam, Umar
    Rajab, Abdul
    Suwarno
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1249 - 1252
  • [38] Phase-resolved study on partial discharge for degradation diagnosis in polymeric insulating materials using model electrode system
    Komori, F
    Kojima, A
    Hikita, M
    Suzuoki, Y
    Mizutani, T
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS - ICSD '98, 1998, : 153 - 156
  • [39] Comparative Study of Partial Discharge Characteristics and Dissolved Gas Analysis on Palm-Based Oil as Insulating Material
    Susilo, Achmad
    Muslim, Joko
    Arief, Yanuar Z.
    Muhamad, Nor Asiah
    Hikita, Masayuki
    Kozako, Masahiro
    Tsuchie, Motoo
    Suzuki, Takashi
    Hatada, Satoshi
    Kanetani, Akinori
    Kano, Takaaki
    Suwarno
    Khayam, Umar
    2014 INTERNATIONAL CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2014, : 232 - 236
  • [40] CHARACTERISTICS OF PARTIAL DISCHARGE ON TYPICAL DEFECTS OF 12 kV POWER TRANSFORMERS WITH OPTICAL FIBER BASED ON POWER SPECTRUM DENSITY METHODS
    Lin Yong-Ping
    Zhu Fa-Cai
    Shao Zhen-Hua
    Zhang Hong-Yi
    JOURNAL OF THE BALKAN TRIBOLOGICAL ASSOCIATION, 2016, 22 (03): : 2252 - 2264