Partial Discharge-induced Degradation Characteristics of Insulating Materials of Gas-filled Power Transformers

被引:9
|
作者
Okabe, Shigemitsu [1 ]
Ueta, Genyo [1 ]
Wada, Haruhisa [2 ]
Okubo, Hitoshi [3 ]
机构
[1] Tokyo Elect Power Co Ltd, Tsurumi Ku, Kanagawa 2308510, Japan
[2] Toshiba Co Ltd, Kawasaki Ku, Kanagawa 2100862, Japan
[3] Nagoya Univ, Dept Elect Engn & Comp Sci, Furo 4648603, Japan
关键词
Gas-filled power transformer; partial discharge (PD); polyethylene terephthalate (PET) film; Nomex (R) board; pressboard; residual impulse withstand voltage; harmful partial discharge level; insulation degradation;
D O I
10.1109/TDEI.2010.5658221
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The soundness of a transformer under an operating voltage is evaluated in partial discharge (PD) test of long-duration ac withstand voltage test. At present, the same criteria for evaluating oil-filled transformers are adopted as those for evaluating gas-filled transformers in this PD test. However, gas-filled transformers are made of different insulating materials than those for oil-filled transformers, and therefore they may have different strengths against PDs from oil-filled transformers. Therefore, it is necessary to establish PD evaluation criteria for gas-filled transformers. This paper, as the first step toward this objective, discusses the study of solid insulating materials used in gas-filled transformers in terms of the generated PD magnitudes and the degrees of damage of insulation and examines the harmful PD levels that lower the residual impulse withstand voltage. As a result, it identified the PD-induced degradation patterns of some insulating materials used in gas-filled transformers, i.e., polyethylene terephthalate (PET) films and Nomex (R) boards and evaluated the harmful PD levels based on the residual impulse withstand voltages. It was also verified that the insulations of pressboards are not degraded even by relatively large PDs.
引用
收藏
页码:1715 / 1723
页数:9
相关论文
共 50 条
  • [11] Partial Discharge Signal Propagation Characteristics Inside the Winding of Gas-filled Power Transformer - Experimental Study Using Winding Models in the Air
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1658 - 1667
  • [12] Discharge Characteristics of a Gas-Filled Capillary Plasma for Laser Wakefield Acceleration
    Kim, M. S.
    Jang, D. G.
    Uhm, H. S.
    Hwang, S. W.
    Lee, I. W.
    Suk, H.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (08) : 1638 - 1643
  • [13] Gas-liquid hybrid discharge-induced degradation of diuron in aqueous solution
    Feng, Jingwei
    Zheng, Zheng
    Luan, Jingfei
    Li, Kunquan
    Wang, Lianhong
    Feng, Jianfang
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 164 (2-3) : 838 - 846
  • [14] Breakdown characteristics of gas-filled transformers and reactors under lightning and switching impulse voltages
    Yamamoto, Takashi
    Ueta, Genyo
    Okabe, Shigemitsu
    Yoshida, Ikki
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (04) : 508 - 512
  • [15] Study of Characteristics of Partial Discharge for Assessment of Condition of Electrical Insulating Materials of Power Supply System
    Poluyanovich, Nikolay K.
    Dubyago, Marina N.
    APPLIED MECHANICS AND MECHANICAL ENGINEERING IV, 2014, 459 : 70 - 75
  • [16] On the correlation among partial discharge patterns and degradation in large power transformers
    Hyde, JR
    Kemp, IJ
    Nesbitt, A
    Funnell, I
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 194 - 197
  • [17] Correlation of Gas Generation Characteristics with Partial Discharge Energy in an Insulating Liquid
    Bian, Gechen
    Liu, Qiang
    Jarman, Paul
    Mavrommatis, Pascal
    2023 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, CEIDP, 2023,
  • [18] Degradation of Insulating Polymer Materials Exposed to Partial Discharge under NOx Environment
    Ehara, Yoshiyasu
    Kubota, Daisuke
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 417 - 420
  • [19] On-line partial discharge measuring technique in high-pressure gas-filled terminations
    Ahmed, N
    Srinivas, N
    1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 386 - 389
  • [20] Processes in insulating gas induced by electrical breakdown responsible for commercial gas-filled surge arresters delay response
    Pejovic, Milic
    Stankovic, Koviljka
    Fetahovic, Irfan
    Pejovic, Momcilo
    VACUUM, 2017, 137 : 85 - 91