Prospective Comparison of 70-kVp Single -Energy CT versus Dual -Energy CT: Which is More Suitable for CT Angiography with Low Contrast Media

被引:8
|
作者
Yoshida, Morikatsu [1 ]
Nakaura, Takeshi [2 ]
Sentaro, Takada [1 ]
Tanoue, Shota [2 ]
Inada, Hatsuki [1 ]
Utsunomiya, Daisuke [3 ]
Sakaino, Naritsugu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Dept Radiol, 854-1 Jikiba, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Dept Diagnost Radiol, Fac Life Sci, Kumamoto, Japan
[3] Yokohama City Univ, Dept Radiol, Sch Med, Yokohama, Kanagawa, Japan
[4] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
ABDOMINAL DYNAMIC CT; LOW TUBE VOLTAGE; RENAL-FAILURE; AORTOGRAPHY; REDUCTION; SETTINGS; IMPACT; NOISE;
D O I
10.1016/j.acra.2019.07.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare the objective and subjective image qualities between single-energy computed tomography (CT) at 70 kVp and virtual monoenergetic imaging (VMI) of dual-source dual-energy CT for CT angiography with 180 mgI/kg. Materials and Methods: Total 63 patients scanned with 180 mgI/kg were randomly divided into two groups: Group A (32 patients) underwent CT angiography at 70-kVp, and Group B (31 patients) underwent dual-energy CT. VMI sets were generated at 10-keV increments between 40 and 100 keV. We calculated aortic attenuation, contrast-to-noise-ratio (CNR), signal-to-noise-ratio, figure of merit of CNR, and effective dose for each protocol. Three radiologists scored overall image quality and various arteries’ visibility using a four-point scale. Quantitative and qualitative comparisons between 70 kVp and VMI with the highest CNR were performed with the two-tailed t test or Kruskal–Wallis test. Results: The 40-keV images offered the highest CNR among VMIs. Aortic attenuation at 70 kVp was significantly lower than that at 40 keV (p < 0.001). However, the signal-to-noise-ratio, CNR, and figure of merit of CNR were significantly higher at 70 kVp than those at 40-keV (p < 0.001, p < 0.05, and p < 0.05, respectively). The effective dose of each group was almost equal. The qualitative visibility scores for various arteries, except the ascending and upper-abdominal aorta, were also better at 70 kVp than those at 40 keV. Conclusion: Aortic attenuation at 70 kVp with 180 mg I/kg was lower than that of VMI at 40 keV, and the objective and subjective image qualities were higher at 70 kVp than those at 40 keV. © 2019 The Association of University Radiologists
引用
收藏
页码:E116 / E122
页数:7
相关论文
共 50 条
  • [41] Utility of dual-energy spectral CT and low-iodine contrast medium in DIEP angiography
    Gao, Zhipeng
    Meng, Donghua
    Lu, Hong
    Yao, Bingyu
    Huang, Ning
    Ye, Zhaoxiang
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B64 - B71
  • [42] Dual-energy CT Imaging Using a Single-energy CT Data via Deep Learning: A Contrast-enhanced CT Study
    Zhao, W.
    Lv, T.
    Chen, Y.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S43 - S43
  • [43] Effects of High-concentration contrast material and low-voltage CT on contrast for multiphasic CT of the upper abdomen: comparison using the simulation with virtual monochromatic imaging obtained by fast-switch kVp dual-energy CT
    Sakane, Makoto
    Kim, Tonsok
    Hori, Masatoshi
    Onishi, Hiromitsu
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    SPRINGERPLUS, 2014, 3 : 1 - 9
  • [44] Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography-A Prospective Randomized Trial
    Yuan, Ren
    Shuman, William P.
    Earls, James P.
    Hague, Cameron J.
    Mumtaz, Hina A.
    Scott-Moncrieff, Andrew
    Elli, Jennifer D.
    Mayo, John R.
    Leipsic, Jonathon A.
    RADIOLOGY, 2012, 262 (01) : 290 - 297
  • [45] Complementary contrast media for metal artifact reduction in Dual-Energy CT
    Lambert, Jack W.
    Edic, Peter M.
    FitzGerald, Paul
    Torres, Andrew S.
    Yeh, Benjamin M.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [46] Application of dual low dose technology in dual energy head and neck CT angiography
    Zhang, Yi-Chi
    Ji, Yiding
    Chi, Jing
    Yin, Sheng-Nan
    Qiu, Jue
    MINERVA MEDICA, 2023,
  • [47] Dose levels at coronary CT angiography—a comparison of Dual Energy-, Dual Source- and 16-slice CT
    J. Matthias Kerl
    Ralf W. Bauer
    Tobias B. Maurer
    Rene Aschenbach
    Huedayi Korkusuz
    Thomas Lehnert
    Simon Deseive
    Hanns Ackermann
    Thomas J. Vogl
    European Radiology, 2011, 21 : 530 - 537
  • [48] Low radiation and low-contrast dose pulmonary CT angiography: Comparison of 80 kVp/60 ml and 100 kVp/80 ml protocols
    Viteri-Ramirez, G.
    Garcia-Lallana, A.
    Simon-Yarza, I.
    Broncano, J.
    Ferreira, M.
    Pueyo, J. C.
    Villanueva, A.
    Bastarrika, G.
    CLINICAL RADIOLOGY, 2012, 67 (09) : 833 - 839
  • [49] CT Angiography of the Aorta: Prospective Evaluation of Individualized Low-Volume Contrast Media Protocols
    Higashigaito, Kai
    Schmid, Tabea
    Puippe, Gilbert
    Morsbach, Fabian
    Lachat, Mario
    Seifert, Burkhardt
    Pfammatter, Thomas
    Alkadhi, Hatem
    Husarik, Daniela B.
    RADIOLOGY, 2016, 280 (03) : 960 - 968
  • [50] High-Pitch Coronary CT Angiography at 70 kVp Adopting a Protocol of Low Injection Speed and Low Volume of Contrast Medium
    Feng, Ruiqi
    Tong, Jiajie
    Liu, Xiaofei
    Zhao, Yu
    Zhang, Liang
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (05) : 763 - 772