CT Angiography of the Aorta: Prospective Evaluation of Individualized Low-Volume Contrast Media Protocols

被引:51
|
作者
Higashigaito, Kai [1 ]
Schmid, Tabea [1 ]
Puippe, Gilbert [1 ]
Morsbach, Fabian [1 ]
Lachat, Mario [2 ]
Seifert, Burkhardt [3 ]
Pfammatter, Thomas [1 ]
Alkadhi, Hatem [1 ]
Husarik, Daniela B. [1 ]
机构
[1] Univ Zurich, Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Univ Zurich Hosp, Div Vasc Surg, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Dept Biostat, Epidemiol Biostat & Prevent Inst, Zurich, Switzerland
关键词
IMAGE-QUALITY; ROW CT; K-EDGE; ENHANCEMENT; NEPHROPATHY; SELECTION; ANEURYSM; REPAIR; TIME;
D O I
10.1148/radiol.2016151982
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively develop individualized low-volume contrast media (CM) protocols adapted to tube voltage in patients undergoing computed tomographic (CT) angiography of the aorta. Materials and Methods: The study was approved by the institutional review board and local ethics committee. All patients provided written informed consent. CT angiography was performed by using automated attenuation-based tube voltage selection (ATVS) (range, 70-150 kVp; 10-kVp increments). Iodine attenuation curves from an ex vivo experiment in a phantom were used to design CM protocols for CT angiography of the thoracoabdominal aorta in 129 consecutive patients (hereafter, cohort A). Further modified CM protocols based on results in cohort A were designed with the aim of homogeneous vascular attenuation of 300-350 HU across tube voltages and were applied to another 61 consecutive patients (cohort B). Three independent blinded radiologists assessed subjective image quality, and one reader determined objective image quality. The Kruskal-Wallis test was performed to test for differences in subjective image quality, and linear regression was performed to test for differences in objective image quality between the automatically selected tube voltages. Results: Experiments revealed tube voltage-dependent iodine attenuation curves, which were used to determine the CM protocols in cohort A; these ranged from 68 mL at 110 kVp to 45 mL at 80 kVp. In both cohorts, ATVS selected 80 kVp in 62 patients, 90 kVp in 84, 100 kVp in 33, and 110 kVp in 11. In cohort A, image quality that was satisfactory or better was attained in 126 (98%) of 129 patients who had no significant differences in subjective image quality between tube voltages (P =.106) but who did have significant differences in attenuation and contrast-to-noise ratio (CNR) (P<.001 for both). In cohort B, the furthermodified CM protocol (from 33 mL at 80 kVp to 68 mL at 110 kVp) yielded image quality that was satisfactory or better in all 61 (100%) patients, without significant differences in subjective image quality (P =.178), and without significant differences between tube voltage and attenuation (P =.108), noise (P =.250), or CNR (P =.698). Conclusion: Individualized low-volume CM protocols based on automatically selected tube voltages are feasible and yield diagnostic image quality for CT angiography of the aorta. (C) RSNA, 2016.
引用
收藏
页码:960 / 968
页数:9
相关论文
共 50 条
  • [1] Feasibility of low contrast media volume in CT angiography of the aorta
    Seehofnerova, Anna
    Kok, Madeleine
    Mihl, Casper
    Douwes, Dave
    Sailer, Anni
    Nijssen, Estelle
    Michiel, J. W. de Haan
    Wildberger, Joachim E.
    Das, Marco
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2015, 2 : 58 - 65
  • [2] Individualized CT Angiography Protocols for the Evaluation of the Aorta: A Feasibility Study
    Kok, Madeleine
    de Haan, Michael W.
    Mihl, Casper
    Eijsvoogel, Nienke G.
    Hendriks, Babs M. F.
    Sailer, Anna M.
    Derks, Kris
    Schnerr, Roald S.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    Das, Marco
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (04) : 531 - 538
  • [3] Individualized scan protocols for CT angiography: an animal study for contrast media or radiation dose optimization
    Haubold, Johannes
    Zensen, Sebastian
    Hosch, Rene
    Schaarschmidt, Benedikt Michael
    Bos, Denise
    Schmidt, Bernhardt
    Flohr, Thomas
    Li, Yan
    Forsting, Michael
    Pietsch, Hubertus
    Nensa, Felix
    Jost, Gregor
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [4] Individualized scan protocols for CT angiography: an animal study for contrast media or radiation dose optimization
    Johannes Haubold
    Sebastian Zensen
    René Hosch
    Benedikt Michael Schaarschmidt
    Denise Bos
    Bernhardt Schmidt
    Thomas Flohr
    Yan Li
    Michael Forsting
    Hubertus Pietsch
    Felix Nensa
    Gregor Jost
    European Radiology Experimental, 7
  • [5] CT Angiography of the Aorta Using Photon-counting Detector CT with Reduced Contrast Media Volume
    Higashigaito, Kai
    Mergen, Victor
    Eberhard, Matthias
    Jungblut, Lisa
    Hebeisen, Monika
    Ratzer, Susan
    Zanini, Bettina
    Kobe, Adrian
    Martini, Katharina
    Euler, Andre
    Alkadhi, Hatem
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (01):
  • [6] Evaluation of Low-kVp Low-Volume Iodinated Contrast Protocol for Coronary CT Angiography Using Retrospective ECG Gating
    Kapoor, Atul
    Mahajan, Goldaa
    Kapoor, Aprajita
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (04): : 910 - 916
  • [7] Automated tube voltage selection and adapted contrast media injection protocols in CT angiography of the thoracoabdominal aorta
    N. G. Eijsvoogel
    B. M. F. Hendriks
    M. Kok
    B. M. E. Mees
    C. Mihl
    J. E. Wildberger
    M. Das
    Chinese Journal of Academic Radiology, 2021, 4 : 116 - 124
  • [8] Automated tube voltage selection and adapted contrast media injection protocols in CT angiography of the thoracoabdominal aorta
    Eijsvoogel, N. G.
    Hendriks, B. M. F.
    Kok, M.
    Mees, B. M. E.
    Mihl, C.
    Wildberger, J. E.
    Das, M.
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2021, 4 (02) : 116 - 124
  • [9] Comparison of four contrast medium delivery protocols in low-iodine and low-radiation dose CT angiography of the aorta
    Chen, P. -A.
    Huang, E. P.
    Chen, K. -T.
    Chen, Y. -C.
    Huang, Y. -L.
    Chuo, C. -C.
    Wu, F. -Z.
    Wu, M. -T.
    CLINICAL RADIOLOGY, 2020, 75 (10) : 797.e9 - 797.e19
  • [10] Low tube voltage and low contrast material volume cerebral CT angiography
    Song Luo
    Long Jiang Zhang
    Felix G. Meinel
    Chang Sheng Zhou
    Li Qi
    Andrew D. McQuiston
    U. Joseph Schoepf
    Guang Ming Lu
    European Radiology, 2014, 24 : 1677 - 1685