CT Angiography of the Aorta: Prospective Evaluation of Individualized Low-Volume Contrast Media Protocols

被引:51
|
作者
Higashigaito, Kai [1 ]
Schmid, Tabea [1 ]
Puippe, Gilbert [1 ]
Morsbach, Fabian [1 ]
Lachat, Mario [2 ]
Seifert, Burkhardt [3 ]
Pfammatter, Thomas [1 ]
Alkadhi, Hatem [1 ]
Husarik, Daniela B. [1 ]
机构
[1] Univ Zurich, Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Univ Zurich Hosp, Div Vasc Surg, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Dept Biostat, Epidemiol Biostat & Prevent Inst, Zurich, Switzerland
关键词
IMAGE-QUALITY; ROW CT; K-EDGE; ENHANCEMENT; NEPHROPATHY; SELECTION; ANEURYSM; REPAIR; TIME;
D O I
10.1148/radiol.2016151982
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively develop individualized low-volume contrast media (CM) protocols adapted to tube voltage in patients undergoing computed tomographic (CT) angiography of the aorta. Materials and Methods: The study was approved by the institutional review board and local ethics committee. All patients provided written informed consent. CT angiography was performed by using automated attenuation-based tube voltage selection (ATVS) (range, 70-150 kVp; 10-kVp increments). Iodine attenuation curves from an ex vivo experiment in a phantom were used to design CM protocols for CT angiography of the thoracoabdominal aorta in 129 consecutive patients (hereafter, cohort A). Further modified CM protocols based on results in cohort A were designed with the aim of homogeneous vascular attenuation of 300-350 HU across tube voltages and were applied to another 61 consecutive patients (cohort B). Three independent blinded radiologists assessed subjective image quality, and one reader determined objective image quality. The Kruskal-Wallis test was performed to test for differences in subjective image quality, and linear regression was performed to test for differences in objective image quality between the automatically selected tube voltages. Results: Experiments revealed tube voltage-dependent iodine attenuation curves, which were used to determine the CM protocols in cohort A; these ranged from 68 mL at 110 kVp to 45 mL at 80 kVp. In both cohorts, ATVS selected 80 kVp in 62 patients, 90 kVp in 84, 100 kVp in 33, and 110 kVp in 11. In cohort A, image quality that was satisfactory or better was attained in 126 (98%) of 129 patients who had no significant differences in subjective image quality between tube voltages (P =.106) but who did have significant differences in attenuation and contrast-to-noise ratio (CNR) (P<.001 for both). In cohort B, the furthermodified CM protocol (from 33 mL at 80 kVp to 68 mL at 110 kVp) yielded image quality that was satisfactory or better in all 61 (100%) patients, without significant differences in subjective image quality (P =.178), and without significant differences between tube voltage and attenuation (P =.108), noise (P =.250), or CNR (P =.698). Conclusion: Individualized low-volume CM protocols based on automatically selected tube voltages are feasible and yield diagnostic image quality for CT angiography of the aorta. (C) RSNA, 2016.
引用
收藏
页码:960 / 968
页数:9
相关论文
共 50 条
  • [31] Extravasation of Contrast Media During Diagnostic CT Angiography
    Kobata, Hitoshi
    Sugie, Akira
    Toho, Taichirou
    CEREBROVASCULAR DISEASES, 2012, 34 : 91 - 91
  • [32] CT angiography with gadolinium-based contrast media
    Bonvento, Michael J.
    Moore, William H.
    Button, Terry M.
    Weinmann, Hanns-Joachim
    Yakupov, Renat
    Dilmanian, F. Avraham
    ACADEMIC RADIOLOGY, 2006, 13 (08) : 979 - 985
  • [33] Postmortem whole-body CT angiography: Evaluation of two contrast media solutions
    Ross, Steffen
    Spendlove, Danny
    Bolliger, Stephan
    Christe, Andreas
    Oesterhelweg, Lars
    Grabherr, Silke
    Thali, Michael J.
    Gygax, Erich
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) : 1380 - 1389
  • [34] Takayasu arteritis: Evaluation of the thoracic aorta with CT angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Numano, F
    Shibuya, H
    RADIOLOGY, 1998, 209 (01) : 103 - 109
  • [35] Gadopentetate dimeglumine:: A possible alternative contrast agent for CT angiography of the aorta
    Peña, CS
    Kaufman, JA
    Geller, SC
    Waltman, AC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (01) : 23 - 24
  • [36] Contrast Volume for Preoperative CT Angiography of the Aorta Based on Patient Heart Rate and Body Surface Area: A Pilot Study
    Raymakers, Dominic
    Dubbeldam, Adriana
    Coudyzer, Walter
    Bosmans, Hilde
    Maleux, Geert
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2019, 103 (01):
  • [37] Evaluation of the aorta in infants with simple or complex coarctation of the aorta using CT angiography
    Xiao, Hui-Jun
    Zhan, A-Lai
    Huang, Qing-Wen
    Huang, Rui-Gang
    Lin, Wei-Hua
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [38] Investigating the Use and Optimization of Low Dose kV and Contrast Media in CT Pulmonary Angiography Examination
    Kara, Mustafa
    Kayan, Mustafa
    Cetinkaya, Gursel
    Turkoglu, Sefa
    Kayan, Fatma
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [39] Towards lower radiation and contrast media dose CT angiography of the aorta by artificial intelligence-supported iterative reconstructions
    Halfmann, Moritz C.
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [40] Evaluation of individually body weight adapted contrast media injection in coronary CT-angiography
    Mihl, Casper
    Kok, Madeleine
    Altintas, Sibel
    Kietselaer, Bas L. J. H.
    Turek, Jakub
    Wildberger, Joachim E.
    Das, Marco
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 830 - 836