CT Angiography of the Aorta: Prospective Evaluation of Individualized Low-Volume Contrast Media Protocols

被引:51
|
作者
Higashigaito, Kai [1 ]
Schmid, Tabea [1 ]
Puippe, Gilbert [1 ]
Morsbach, Fabian [1 ]
Lachat, Mario [2 ]
Seifert, Burkhardt [3 ]
Pfammatter, Thomas [1 ]
Alkadhi, Hatem [1 ]
Husarik, Daniela B. [1 ]
机构
[1] Univ Zurich, Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Univ Zurich Hosp, Div Vasc Surg, Raemistr 100, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Dept Biostat, Epidemiol Biostat & Prevent Inst, Zurich, Switzerland
关键词
IMAGE-QUALITY; ROW CT; K-EDGE; ENHANCEMENT; NEPHROPATHY; SELECTION; ANEURYSM; REPAIR; TIME;
D O I
10.1148/radiol.2016151982
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively develop individualized low-volume contrast media (CM) protocols adapted to tube voltage in patients undergoing computed tomographic (CT) angiography of the aorta. Materials and Methods: The study was approved by the institutional review board and local ethics committee. All patients provided written informed consent. CT angiography was performed by using automated attenuation-based tube voltage selection (ATVS) (range, 70-150 kVp; 10-kVp increments). Iodine attenuation curves from an ex vivo experiment in a phantom were used to design CM protocols for CT angiography of the thoracoabdominal aorta in 129 consecutive patients (hereafter, cohort A). Further modified CM protocols based on results in cohort A were designed with the aim of homogeneous vascular attenuation of 300-350 HU across tube voltages and were applied to another 61 consecutive patients (cohort B). Three independent blinded radiologists assessed subjective image quality, and one reader determined objective image quality. The Kruskal-Wallis test was performed to test for differences in subjective image quality, and linear regression was performed to test for differences in objective image quality between the automatically selected tube voltages. Results: Experiments revealed tube voltage-dependent iodine attenuation curves, which were used to determine the CM protocols in cohort A; these ranged from 68 mL at 110 kVp to 45 mL at 80 kVp. In both cohorts, ATVS selected 80 kVp in 62 patients, 90 kVp in 84, 100 kVp in 33, and 110 kVp in 11. In cohort A, image quality that was satisfactory or better was attained in 126 (98%) of 129 patients who had no significant differences in subjective image quality between tube voltages (P =.106) but who did have significant differences in attenuation and contrast-to-noise ratio (CNR) (P<.001 for both). In cohort B, the furthermodified CM protocol (from 33 mL at 80 kVp to 68 mL at 110 kVp) yielded image quality that was satisfactory or better in all 61 (100%) patients, without significant differences in subjective image quality (P =.178), and without significant differences between tube voltage and attenuation (P =.108), noise (P =.250), or CNR (P =.698). Conclusion: Individualized low-volume CM protocols based on automatically selected tube voltages are feasible and yield diagnostic image quality for CT angiography of the aorta. (C) RSNA, 2016.
引用
收藏
页码:960 / 968
页数:9
相关论文
共 50 条
  • [41] Feasibility of Low-volume Injections of Contrast Material with a Body Weight-Adapted Iodine-Dose Protocol in 320-Detector Row Coronary CT Angiography
    Tatsugami, Fuminari
    Matsuki, Mitsuru
    Inada, Yuki
    Kanazawa, Shuji
    Nakai, Go
    Takeda, Yoshihiro
    Morita, Hideaki
    Takada, Haruhiko
    Ashida, Kenji
    Yoshikawa, Shushi
    Fukumura, Katsunori
    Narumi, Yoshifumi
    ACADEMIC RADIOLOGY, 2010, 17 (02) : 207 - 211
  • [42] Comparison of High-Volume PEG Lavage with Low-Volume CT Colonography Bowel Preparations Utilizing Oral Contrast at Optical Colonoscopy
    Lawrence, E.
    Pickhardt, P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [43] Evaluation of Coir Geotextile Reinforcement for Low-Volume Roads
    Anusudha, Visvanathan
    Sunitha, Velayudhan
    Mathew, Samson
    JOURNAL OF NATURAL FIBERS, 2022, 19 (07) : 2402 - 2413
  • [44] Optimizing Contrast Media Injection Protocols in Computed Tomography Angiography at Different Tube Voltages: Evaluation in a Circulation Phantom
    Caruso, Damiano
    Eid, Marwen
    Schoepf, U. Joseph
    De Santis, Domenico
    Varga-Szemes, Akos
    Mangold, Stefanie
    Canstein, Christian
    Lesslie, Virginia W.
    Fuller, Stephen R.
    Ball, B. Devon
    Laghi, Andrea
    De Cecco, Carlo N.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (05) : 804 - 810
  • [45] Determination of circulation time for optimizing contrast media in CT angiography
    Puskas, Z
    Schuierer, G
    RADIOLOGE, 1996, 36 (09): : 750 - 757
  • [46] Rational Approach to the Evaluation of Soils for Low-Volume Roads
    Nunez, Washington Peres
    Pereira Ceratti, Jorge Augusto
    Bressani, Luiz Antonio
    Barbosa Pinheiro, Rinaldo Jose
    Peraca, Vinicius
    Nogueira, Matheus Lemos
    TRANSPORTATION RESEARCH RECORD, 2011, (2205) : 73 - 78
  • [47] Adequacy of an early arterial phase low-volume contrast protocol in 64-detector computed tomography angiography for aortoiliac aneurysms
    Diehm, Nicolas
    Pena, Constantino
    Benenati, James F.
    Tsoukas, Athanassios I.
    Katzen, Barry T.
    JOURNAL OF VASCULAR SURGERY, 2008, 47 (03) : 492 - 498
  • [48] Evaluation of Deflection Bowl Parameters in Low-Volume Roads
    Andrews, Jithin Kurian
    Radhakrishnan, Vishnu
    Koshy, Reebu Zachariah
    JOURNAL OF TRANSPORTATION ENGINEERING PART B-PAVEMENTS, 2023, 149 (04)
  • [49] Evaluation of Bearing Capacity of Low-Volume Roads in Minnesota
    Khazanovich, Lev
    Lukanen, Erland
    Tompkins, Derek
    TRANSPORTATION RESEARCH RECORD, 2014, (2433) : 79 - 86
  • [50] Evaluation of Sustainable Development for Low-Volume Roads in Sarawak
    Buking, Ron Aldrino Chan alias Ron
    Borhan, Muhamad Nazri
    Rahmat, Riza Atiq Abdullah O. K.
    JURNAL KEJURUTERAAN, 2024, 36 (04): : 1373 - 1384