Postmortem whole-body CT angiography: Evaluation of two contrast media solutions

被引:149
|
作者
Ross, Steffen [1 ]
Spendlove, Danny [1 ]
Bolliger, Stephan [1 ]
Christe, Andreas [2 ]
Oesterhelweg, Lars [1 ]
Grabherr, Silke [3 ]
Thali, Michael J. [1 ]
Gygax, Erich [4 ]
机构
[1] Univ Bern, Ctr Forens Imaging & Virtopsy, Inst Forens Med, CH-3012 Bern, Switzerland
[2] Univ Bern, Inselspital Bern, Dept Radiol, CH-3012 Bern, Switzerland
[3] Univ Lausanne, Inst Forens Med, Lausanne, Switzerland
[4] Univ Bern, Inselspital Bern, Cardiovasc Surg Clin, CH-3012 Bern, Switzerland
关键词
angiography; contrast media; noninvasive; autopsy; postmortem whole-body angiography; virtopsy; virtual autopsy;
D O I
10.2214/AJR.07.3082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS. Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin ( five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol ( PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS. The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION. The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues ( cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.
引用
收藏
页码:1380 / 1389
页数:10
相关论文
共 50 条
  • [1] Whole-body MR angiography: Comparison of two protocols for contrast media injection
    Klessen, C
    Asbach, P
    Hein, PA
    Lembcke, A
    Bauknecht, HC
    Huppertz, A
    Nentwig, T
    Hamm, B
    Taupitz, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (05): : 484 - 490
  • [2] Should whole-body CT screening be performed with contrast media?
    Berlin, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 323 - 325
  • [3] Whole body perinatal postmortem CT angiography
    Sarda-Quarello, L.
    Bartoli, C.
    Laurent, P. -E.
    Torrents, J.
    Piercecchi-Marti, M. -D.
    Sigaudy, S.
    Ariey-Bonnet, D.
    Gorincour, G.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (01) : 121 - 124
  • [4] Blunt Polytrauma: Evaluation with 64-Section Whole-Body CT Angiography
    Dreizin, David
    Munera, Felipe
    [J]. RADIOGRAPHICS, 2012, 32 (03) : 609 - 631
  • [5] Whole-body PET angiography on semiconductor PET/CT
    Norikane, Takashi
    Yamamoto, Yuka
    Takami, Yasukage
    Mitamura, Katsuya
    Matsumoto, Keisuke
    Maeda, Yukito
    Yamashita, Yoichi
    Nishiyama, Yoshihiro
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 885 - 888
  • [6] Whole-body PET angiography on semiconductor PET/CT
    Takashi Norikane
    Yuka Yamamoto
    Yasukage Takami
    Katsuya Mitamura
    Keisuke Matsumoto
    Yukito Maeda
    Yoichi Yamashita
    Yoshihiro Nishiyama
    [J]. Journal of Nuclear Cardiology, 2022, 29 : 885 - 888
  • [7] Modified whole-body postmortem computed tomography angiography using neck approach
    Rashid, Saiful Nizam Abdul
    Klop, Anthony Cornelis
    Feng, Siew Sheue
    Mahmud, Rozi
    Singh, Mansharan Kaur Chainchel
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [8] Modified whole-body postmortem computed tomography angiography using neck approach
    Saiful Nizam Abdul Rashid
    Anthony Cornelis Klop
    Siew Sheue Feng
    Rozi Mahmud
    Mansharan Kaur Chainchel Singh
    [J]. Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [9] Whole-Body High-Pitch CT Angiography: Strategies to Reduce Radiation Dose and Contrast Volume
    Manneck, Sebastian
    Hurwitz, Lynne M.
    Seaman, Danielle M.
    Heye, Tobias
    Boll, Daniel T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (06) : 1396 - 1403
  • [10] Demonstration of liver metastases on postmortem whole body CT angiography following inadvertent systemic venous infusion of the contrast medium
    Chris O’Donnell
    Jacqueline Hislop-Jambrich
    Noel Woodford
    Melissa Baker
    [J]. International Journal of Legal Medicine, 2012, 126 : 311 - 314