Individualized scan protocols for CT angiography: an animal study for contrast media or radiation dose optimization

被引:3
|
作者
Haubold, Johannes [1 ]
Zensen, Sebastian [1 ]
Hosch, Rene [1 ,2 ]
Schaarschmidt, Benedikt Michael [1 ]
Bos, Denise [1 ]
Schmidt, Bernhardt [4 ]
Flohr, Thomas [4 ]
Li, Yan [1 ]
Forsting, Michael [1 ]
Pietsch, Hubertus [3 ]
Nensa, Felix [1 ,2 ]
Jost, Gregor [3 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45147 Essen, Germany
[2] Univ Hosp Essen, Inst Artificial Intelligence Med, Essen, Germany
[3] Bayer AG, MR & CT Contrast Media Res, Berlin, Germany
[4] Siemens Healthcare GmbH, Forchheim, Germany
关键词
Animals; Contrast media; Radiation; Tomography (x-ray computed); COMPUTED-TOMOGRAPHY ANGIOGRAPHY; LOW TUBE VOLTAGE; IMAGE-QUALITY; SELECTION; SETTINGS; PHANTOM; SIZE;
D O I
10.1186/s41747-023-00332-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundWe investigated about optimization of contrast media (CM) dose or radiation dose in thoracoabdominal computed tomography angiography (CTA) by automated tube voltage selection (ATVS) system configuration and CM protocol adaption.MethodsIn six minipigs, CTA-optimized protocols were evaluated regarding objective (contrast-to-noise ratio, CNR) and subjective (6 criteria assessed by Likert scale) image quality. Scan parameters were automatically adapted by the ATVS system operating at 90-kV semi-mode and configured for standard, CM saving, or radiation dose saving (image task, quality settings). Injection protocols (dose, flow rate) were adapted manually. This approach was tested for normal and simulated obese conditions.ResultsRadiation exposure (volume-weighted CT dose index) for normal (obese) conditions was 2.4 +/- 0.7 (5.0 +/- 0.7) mGy (standard), 4.3 +/- 1.1 (9.0 +/- 1.3) mGy (CM reduced), and 1.7 +/- 0.5 (3.5 +/- 0.5) mGy (radiation reduced). The respective CM doses for normal (obese) settings were 210 (240) mgI/kg, 155 (177) mgI/kg, and 252 (288) mgI/kg. No significant differences in CNR (normal; obese) were observed between standard (17.8 +/- 3.0; 19.2 +/- 4.0), CM-reduced (18.2 +/- 3.3; 20.5 +/- 4.9), and radiation-saving CTAs (16.0 +/- 3.4; 18.4 +/- 4.1). Subjective analysis showed similar values for optimized and standard CTAs. Only the parameter diagnostic acceptability was significantly lower for radiation-saving CTA compared to the standard CTA.ConclusionsThe CM dose (-26%) or radiation dose (-30%) for thoracoabdominal CTA can be reduced while maintaining objective and subjective image quality, demonstrating the feasibility of the personalization of CTA scan protocols.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Individualized scan protocols for CT angiography: an animal study for contrast media or radiation dose optimization
    Johannes Haubold
    Sebastian Zensen
    René Hosch
    Benedikt Michael Schaarschmidt
    Denise Bos
    Bernhardt Schmidt
    Thomas Flohr
    Yan Li
    Michael Forsting
    Hubertus Pietsch
    Felix Nensa
    Gregor Jost
    European Radiology Experimental, 7
  • [2] Individualized Scan Protocols in Abdominal Computed Tomography Radiation Versus Contrast Media Dose Optimization
    Martens, Bibi
    Jost, Gregor
    Mihl, Casper
    Nijssen, Estelle C.
    Wildberger, Joachim E.
    Schmidt, Bernhard
    Flohr, Thomas
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2022, 57 (06) : 353 - 358
  • [3] CT Angiography of the Aorta: Prospective Evaluation of Individualized Low-Volume Contrast Media Protocols
    Higashigaito, Kai
    Schmid, Tabea
    Puippe, Gilbert
    Morsbach, Fabian
    Lachat, Mario
    Seifert, Burkhardt
    Pfammatter, Thomas
    Alkadhi, Hatem
    Husarik, Daniela B.
    RADIOLOGY, 2016, 280 (03) : 960 - 968
  • [4] Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT
    Konstantin Klambauer
    Thomas Flohr
    Lukas Jakob Moser
    Victor Mergen
    Matthias Eberhard
    Andreas Prokein
    Hatem Alkadhi
    Hubertus Pietsch
    Gregor Jost
    European Radiology Experimental, 9 (1)
  • [5] A rational approach to dose reduction in CT: individualized scan protocols
    Janita E. Wilting
    André Zwartkruis
    Maarten S. van Leeuwen
    Jan Timmer
    Alfons G. Kamphuis
    Michiel Feldberg
    European Radiology, 2001, 11 : 2627 - 2632
  • [6] A rational approach to dose reduction in CT: individualized scan protocols
    Wilting, JE
    Zwartkruis, A
    van Leeuwen, MS
    Timmer, J
    Kamphuis, AGA
    Feldberg, M
    EUROPEAN RADIOLOGY, 2001, 11 (12) : 2627 - 2632
  • [7] Influence of scan protocols on radiation dose estimates for coronary 64-slice CT angiography
    Meyer, TS
    Hausleiter, J
    Huber, E
    Hadamitzky, M
    Ardelean, C
    Martinoff, S
    Schoemig, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 113A - 113A
  • [8] Radiation dose during CT scan with PET/CT clinical protocols
    Son, Hye-Kyung
    Lee, Sang Hoon
    Nam, Sora
    Kim, Hee-Joung
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2210 - 2214
  • [9] Individualized CT Angiography Protocols for the Evaluation of the Aorta: A Feasibility Study
    Kok, Madeleine
    de Haan, Michael W.
    Mihl, Casper
    Eijsvoogel, Nienke G.
    Hendriks, Babs M. F.
    Sailer, Anna M.
    Derks, Kris
    Schnerr, Roald S.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    Das, Marco
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (04) : 531 - 538
  • [10] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80