Prospective Comparison of 70-kVp Single -Energy CT versus Dual -Energy CT: Which is More Suitable for CT Angiography with Low Contrast Media

被引:8
|
作者
Yoshida, Morikatsu [1 ]
Nakaura, Takeshi [2 ]
Sentaro, Takada [1 ]
Tanoue, Shota [2 ]
Inada, Hatsuki [1 ]
Utsunomiya, Daisuke [3 ]
Sakaino, Naritsugu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Dept Radiol, 854-1 Jikiba, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Dept Diagnost Radiol, Fac Life Sci, Kumamoto, Japan
[3] Yokohama City Univ, Dept Radiol, Sch Med, Yokohama, Kanagawa, Japan
[4] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
ABDOMINAL DYNAMIC CT; LOW TUBE VOLTAGE; RENAL-FAILURE; AORTOGRAPHY; REDUCTION; SETTINGS; IMPACT; NOISE;
D O I
10.1016/j.acra.2019.07.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare the objective and subjective image qualities between single-energy computed tomography (CT) at 70 kVp and virtual monoenergetic imaging (VMI) of dual-source dual-energy CT for CT angiography with 180 mgI/kg. Materials and Methods: Total 63 patients scanned with 180 mgI/kg were randomly divided into two groups: Group A (32 patients) underwent CT angiography at 70-kVp, and Group B (31 patients) underwent dual-energy CT. VMI sets were generated at 10-keV increments between 40 and 100 keV. We calculated aortic attenuation, contrast-to-noise-ratio (CNR), signal-to-noise-ratio, figure of merit of CNR, and effective dose for each protocol. Three radiologists scored overall image quality and various arteries’ visibility using a four-point scale. Quantitative and qualitative comparisons between 70 kVp and VMI with the highest CNR were performed with the two-tailed t test or Kruskal–Wallis test. Results: The 40-keV images offered the highest CNR among VMIs. Aortic attenuation at 70 kVp was significantly lower than that at 40 keV (p < 0.001). However, the signal-to-noise-ratio, CNR, and figure of merit of CNR were significantly higher at 70 kVp than those at 40-keV (p < 0.001, p < 0.05, and p < 0.05, respectively). The effective dose of each group was almost equal. The qualitative visibility scores for various arteries, except the ascending and upper-abdominal aorta, were also better at 70 kVp than those at 40 keV. Conclusion: Aortic attenuation at 70 kVp with 180 mg I/kg was lower than that of VMI at 40 keV, and the objective and subjective image qualities were higher at 70 kVp than those at 40 keV. © 2019 The Association of University Radiologists
引用
收藏
页码:E116 / E122
页数:7
相关论文
共 50 条
  • [21] Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Katsura, Masaki
    Kiryu, Shigeru
    Yoshioka, Naoki
    Kunimatsu, Akira
    Ino, Kenji
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (01) : 34 - 39
  • [22] Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans
    van Straten, Marcel
    Schaap, Michiel
    Dijkshoorn, Marcel L.
    Greuter, Marcel J.
    van der Lugt, Aad
    Krestin, Gabriel P.
    Niessen, Wiro J.
    MEDICAL PHYSICS, 2011, 38 (11) : 6128 - 6137
  • [23] Assessment of Liver Fat: Dual-Energy CT versus Conventional CT with and without Contrast
    Xu, Jack Junchi
    Boesen, Mikkel Ranum
    Hansen, Sofie Lindskov
    Ulriksen, Peter Sommer
    Holm, Soren
    Lonn, Lars
    Hansen, Kristoffer Lindskov
    DIAGNOSTICS, 2022, 12 (03)
  • [24] The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT
    Xin, Lei
    Yang, Xiaotang
    Huang, Ning
    Du, Xiaosong
    Zhang, Jianxin
    Wang, Yanyan
    Hou, Lina
    Gao, Jinfang
    ABDOMINAL IMAGING, 2015, 40 (07): : 2894 - 2899
  • [25] The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT
    Lei Xin
    Xiaotang Yang
    Ning Huang
    Xiaosong Du
    Jianxin Zhang
    Yanyan Wang
    Lina Hou
    Jinfang Gao
    Abdominal Imaging, 2015, 40 : 2894 - 2899
  • [26] Salvage of Suboptimal Enhancement of Pulmonary Artery in Pulmonary CT Angiography Studies: Rapid kVp Switch Dual Energy CT Experience
    Bayraktaroglu, Selen
    Cinkooglu, Akin
    Ceylan, Naim
    Savas, Recep
    IRANIAN JOURNAL OF RADIOLOGY, 2020, 17 (02)
  • [27] Application of dual-energy CT with prospective ECG-gating in cardiac CT angiography for children: Radiation and contrast agent dose
    Xie, Mingye
    Wang, Haoru
    Tang, Shilong
    Chen, Mingjing
    Li, Ting
    He, Ling
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [28] Quantitative comparison of dual-energy CT and differential phase contrast CT imaging methods
    Zhang, Xin
    Su, Ting
    Xia, Dongmei
    Liang, Dong
    Ge, Yongshuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [29] In Vivo Comparison of Radiation Exposure of Dual-Energy CT Versus Low-Dose CT Versus Standard CT for Imaging Urinary Calculi
    Jepperson, Maria A.
    Cernigliaro, Joseph G.
    Ibrahim, El-Sayed H.
    Morin, Richard L.
    Haley, William E.
    Thiel, David D.
    JOURNAL OF ENDOUROLOGY, 2015, 29 (02) : 141 - 146
  • [30] In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
    Mongan, John
    Rathnayake, Samira
    Fu, Yanjun
    Wang, Runtang
    Jones, Ella F.
    Gao, Dong-Wei
    Yeh, Benjamin M.
    RADIOLOGY, 2012, 265 (01) : 267 - 272