Effect of the photon counting CT acquisition on beam hardening artifacts

被引:0
|
作者
Shikhaliev, PM [1 ]
机构
[1] Univ Calif Irvine, Irvine, CA 92717 USA
关键词
D O I
10.1118/1.1998253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Low noise performance of the photon counting x‐ray image acquisition applies also to CT when CT projections are acquired using a photon counting detector. However, the photon counting detector assigns a different weighting factor to the photons as compared to charge integrating, and the photon energy spectrum in the output of the detector is represented differently. This results in different magnitudes of the beam hardening artifacts in CT images acquired with photon counting and charge integrating detectors. Purpose of this work was to evaluate the effect of the photon counting on beam hardening artifacts in CT. Method and Materials: CT images of the head and breast equivalent phantoms including high and low contrast inserts were simulated at 120 kVp and 90 kVp x‐ray tube voltages. Photon counting, charge integrating and energy weighting detectors with photon energy weighting factors of 1, E and E−3, respectively, were considered. Magnitudes of the beam hardening artifacts were quantified and compared for these detectors. Results: Photon counting detector resulted in 4.5% increase of the magnitude of beam hardening artifacts from bone inserts as compared to charge integrating. The most optimal weighting of E−3, which provides the highest SNR, however, resulted in 18% increase in beam hardening artifacts from bone inserts. The magnitude of the “cupping” artifacts was higher by 2% and 5% for photon counting and energy weighting detectors, respectively, as compared to charge integrating. Only the photon counting provided accurate representation of the beam hardening effect due to its flat energy weighting. The charge integrating and energy weighting distorted the beam hardening effect because of energy dependent weighting factors. Conclusion: It is concluded that the low noise capabilities of the photon counting CT will not be compromised by the slight increase on appearance of the beam hardening artifacts. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [41] Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Ernst, Benjamin P.
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [42] Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Benjamin P. Ernst
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 14
  • [43] Effect of Temperature Variation on the Energy Response of a Photon Counting Silicon CT Detector
    Bornefalk, Hans
    Persson, Mats
    Xu, Cheng
    Karlsson, Staffan
    Svensson, Christer
    Danielsson, Mats
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 1442 - 1449
  • [44] Clinical applications of photon counting detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Baffour, Francis I.
    Diehn, Felix E.
    Ferrero, Andrea
    Glazebrook, Katrina N.
    Horst, Kelly K.
    Johnson, Tucker F.
    Leng, Shuai
    Mileto, Achille
    Rajiah, Prabhakar Shantha
    Schmidt, Bernhard
    Yu, Lifeng
    Flohr, Thomas G.
    Fletcher, Joel G.
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5309 - 5320
  • [45] Advanced Imaging Technology: Photon Counting CT
    Jalal, Sabeena
    Nicolaou, Savvas
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2024, 75 (01): : 20 - 21
  • [46] Photon-counting CT: Embracing the Change
    Ananthakrishnan, Lakshmi
    RADIOGRAPHICS, 2023, 43 (05)
  • [47] Photon-counting CT in lung imaging
    Tarnoki, adam Domonkos
    Tarnoki, David Laszlo
    Maurovich-Horvat, Pal
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2025, 19 (02) : 77 - 81
  • [48] Clinical applications of photon counting detector CT
    Cynthia H. McCollough
    Kishore Rajendran
    Francis I. Baffour
    Felix E. Diehn
    Andrea Ferrero
    Katrina N. Glazebrook
    Kelly K. Horst
    Tucker F. Johnson
    Shuai Leng
    Achille Mileto
    Prabhakar Shantha Rajiah
    Bernhard Schmidt
    Lifeng Yu
    Thomas G. Flohr
    Joel G. Fletcher
    European Radiology, 2023, 33 : 5309 - 5320
  • [49] Optimal Selection of Thresholds for Photon Counting CT
    O'Donnell, Thomas
    Schoeck, Friederike
    Cheheltani, Rabee
    Cormode, David
    Fayad, Zahi A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [50] Abdominal applications of photon-counting CT
    Khanungwanitkul, Khanin
    Sliwicka, Olga
    Schwartz, Fides Regina
    BRITISH JOURNAL OF RADIOLOGY, 2024,