Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT

被引:3
|
作者
Layer, Yannik C. [1 ]
Mesropyan, Narine [1 ]
Kupczyk, Patrick A. [1 ]
Luetkens, Julian A. [1 ]
Isaak, Alexander [1 ]
Dell, Tatjana [1 ]
Ernst, Benjamin P. [2 ]
Attenberger, Ulrike I. [1 ]
Kuetting, Daniel [1 ]
机构
[1] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Venusberg Campus 1, D-53127 Bonn, Germany
[2] Univ Hosp Bonn, Dept Otorhinolaryngol, Venusberg Campus 1, D-53127 Bonn, Germany
关键词
DUAL-ENERGY CT; METAL ARTIFACTS; RECONSTRUCTION; HEAD; QUALITY; PHYSICS;
D O I
10.1038/s41598-023-50926-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (>= 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 +/- 98.16; VMI130 keV: - 0.55 +/- 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Benjamin P. Ernst
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 14
  • [2] Photon-Counting Detector CT Virtual Monoenergetic Images in Cervical Trauma Imaging-Optimization of Dental Metal Artifacts and Image Quality
    Dillinger, Daniel
    Overhoff, Daniel
    Froelich, Matthias F.
    Kaatsch, Hanns L.
    Booz, Christian
    Hagen, Achim
    Vogl, Thomas J.
    Schoenberg, Stefan O.
    Waldeck, Stephan
    DIAGNOSTICS, 2024, 14 (06)
  • [3] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 13
  • [5] Photon-Counting Detector CT Virtual Monoenergetic Images for Coronary Artery Stenosis Quantification: Phantom and In Vivo Evaluation
    Wolf, Elias V.
    Halfmann, Moritz C.
    Varga-Szemes, Akos
    Fink, Nicola
    Kloeckner, Roman
    Bockius, Stefanie
    Allmendinger, Thomas
    Hagenauer, Junia
    Koehler, Till
    Kreitner, Karl-Friedrich
    Schoepf, U. Joseph
    Muenzel, Thomas
    Dueber, Christoph
    Gori, Tommaso
    Yang, Yang
    Hell, Michaela M.
    Emrich, Tilman
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (03)
  • [6] Pseudoenhancement in Cystic Renal Lesions - Impact of Virtual Monoenergetic Images of Photon-Counting Detector CT on Lesion Classification
    Schade, Katharina Alexandra
    Mergen, Victor
    Sartoretti, Thomas
    Alkadhi, Hatem
    Euler, Andre
    ACADEMIC RADIOLOGY, 2023, 30 : S305 - S313
  • [7] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    CLINICAL IMAGING, 2023, 102 : 109 - 115
  • [8] Photon-counting CT to Virtual Noncontrast CT Images
    Pourmorteza, Amir
    RADIOLOGY, 2023, 306 (01) : 205 - 206
  • [9] Is There Still a Role for Two-Phase Contrast-Enhanced CT and Virtual Monoenergetic Images in the Era of Photon-Counting Detector CT?
    Estler, Arne
    Nikolaou, Konstantin
    Schoenberg, Stefan O.
    Bamberg, Fabian
    Froelich, Matthias F.
    Tollens, Fabian
    Verloh, Niklas
    Weiss, Jakob
    Horger, Marius
    Hagen, Florian
    DIAGNOSTICS, 2023, 13 (08)
  • [10] Cardiac Virtual Noncontrast Images for Calcium Quantification with Photon-counting Detector CT
    Mergen, Victor
    Ghouse, Sadaf
    Sartoretti, Thomas
    Manka, Robert
    Euler, Andre
    Kasel, Albert M.
    Alkadhi, Hatem
    Eberhard, Matthias
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (03):