Effect of the photon counting CT acquisition on beam hardening artifacts

被引:0
|
作者
Shikhaliev, PM [1 ]
机构
[1] Univ Calif Irvine, Irvine, CA 92717 USA
关键词
D O I
10.1118/1.1998253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Low noise performance of the photon counting x‐ray image acquisition applies also to CT when CT projections are acquired using a photon counting detector. However, the photon counting detector assigns a different weighting factor to the photons as compared to charge integrating, and the photon energy spectrum in the output of the detector is represented differently. This results in different magnitudes of the beam hardening artifacts in CT images acquired with photon counting and charge integrating detectors. Purpose of this work was to evaluate the effect of the photon counting on beam hardening artifacts in CT. Method and Materials: CT images of the head and breast equivalent phantoms including high and low contrast inserts were simulated at 120 kVp and 90 kVp x‐ray tube voltages. Photon counting, charge integrating and energy weighting detectors with photon energy weighting factors of 1, E and E−3, respectively, were considered. Magnitudes of the beam hardening artifacts were quantified and compared for these detectors. Results: Photon counting detector resulted in 4.5% increase of the magnitude of beam hardening artifacts from bone inserts as compared to charge integrating. The most optimal weighting of E−3, which provides the highest SNR, however, resulted in 18% increase in beam hardening artifacts from bone inserts. The magnitude of the “cupping” artifacts was higher by 2% and 5% for photon counting and energy weighting detectors, respectively, as compared to charge integrating. Only the photon counting provided accurate representation of the beam hardening effect due to its flat energy weighting. The charge integrating and energy weighting distorted the beam hardening effect because of energy dependent weighting factors. Conclusion: It is concluded that the low noise capabilities of the photon counting CT will not be compromised by the slight increase on appearance of the beam hardening artifacts. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
下载
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [31] Photon-counting CT urogram: optimal acquisition potential (kV) determination for virtual noncontrast creation
    Dane, Bari
    Freedman, Daniel
    Qian, Kun
    Ginocchio, Luke
    Smereka, Paul
    Megibow, Alec
    ABDOMINAL RADIOLOGY, 2024, 49 (03) : 868 - 874
  • [32] Photon-counting CT urogram: optimal acquisition potential (kV) determination for virtual noncontrast creation
    Bari Dane
    Daniel Freedman
    Kun Qian
    Luke Ginocchio
    Paul Smereka
    Alec Megibow
    Abdominal Radiology, 2024, 49 : 868 - 874
  • [33] Effects of energy-bin acquisition methods on noise properties in photon-counting spectral CT
    Schmidt, Taly Gilat
    Zimmerman, Kevin C.
    Sidky, Emil Y.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [34] Type II beam hardening artifacts in phase contrast imaging
    Bevins, Nicholas
    Li, Ke
    Zambelli, Joseph
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [35] A Deep-Learning-Based Method for Correction of Bone-Induced CT Beam-Hardening Artifacts
    Ji, Xu
    Gao, Dazhi
    Gan, Yimin
    Zhang, Yikun
    Xi, Yan
    Quan, Guotao
    Lu, Zhikai
    Chen, Yang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [36] MODULATED LASER BEAM PHOTON COUNTING DISTRIBUTIONS
    PEARL, P
    TROUP, GJ
    PHYSICS LETTERS A, 1968, A 27 (08) : 560 - &
  • [37] DOUBLE BEAM PHOTON-COUNTING SPECTROPHOTOMETER
    SCHLESINGER, M
    SZCZUREK, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1973, 44 (12): : 1720 - 1721
  • [38] Simultaneous correction of limited-angular-range and beam-hardening artifacts in dual-energy CT
    Chen, Buxin
    Zhang, Zheng
    Xia, Dan
    Sidky, Emil Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [39] Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Ernst, Benjamin P.
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [40] Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT
    Yannik C. Layer
    Narine Mesropyan
    Patrick A. Kupczyk
    Julian A. Luetkens
    Alexander Isaak
    Tatjana Dell
    Benjamin P. Ernst
    Ulrike I. Attenberger
    Daniel Kuetting
    Scientific Reports, 14