Improved solar milk chilling system using variable refrigerant flow technology (VRF)

被引:13
|
作者
Khan, Khawar Saeed [1 ]
Amjad, Waseem [2 ]
Munir, Anjum [2 ]
Hensel, Oliver [1 ]
机构
[1] Univ Kassel, Dept Agr & Blosyst Engn, Kassel, Germany
[2] Univ Agr Faisalabad, Dept Energy Syst Engn, Faisalabad, Pakistan
关键词
Solar energy; Variable refrigerant flow technology; Decentralized milk chilling; Torque load minimizing; PERFORMANCE;
D O I
10.1016/j.solener.2020.01.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The improper post milking handling and storage results in a complete wastage due to the microorganisms and bacterial multiplication present in raw milk. The torque load minimalizing in the chilling unit using a solar photovoltaic (PV) is indeed a challenging task for the smooth functioning of the milk chilling system especially for the conventional (reciprocating) type of compressors. The variable refrigerant flow (VRF) technology not only solves the toque load problem but also reduces the size of peak power requirement of PV array. The present study enables the design of an improved solar chilling system consists of a chilling tank (200 L capacity) coupled with one tonne of refrigeration unit powered by PV panels (2 kWp) and employing VRF technology to make system more energy efficient by reducing the torque load. Experiments were conducted using different batch sizes (50, 100, 150 and 200 L) to decrease the raw milk temperature from 30 degrees C to 4 degrees C. During optimization phase the comparative power required to run various types of compressors (reciprocating, rotary with capacitor and rotary with VRF) were found to be 1.8 kW, 1.2 kW and 0.8 kW, respectively whereas the torque loads were noted to be 3.3 kW, 1.6 kW and zero kW for respective compressor type. The experimental and modeled predicted power consumption and chilling time under different batch sizes revealed excellent correlation coefficient (R-2 = 0.99, P < 0.0001). Around one tonne of refrigeration unit is sufficient to chill 200 L of milk up to 4 degrees C within less than two hours.
引用
收藏
页码:317 / 325
页数:9
相关论文
共 50 条
  • [1] A GENERALIZED ANALYTIC METHOD FOR PREDICTING REFRIGERANT CHARGE AMOUNT IN A VARIABLE REFRIGERANT FLOW (VRF) SYSTEM
    Hong, Sung Bin
    Yoo, Jin Woo
    Kim, Min Soo
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 385 - 392
  • [2] A GENERALIZED ANALYTIC METHOD FOR PREDICTING REFRIGERANT CHARGE AMOUNT IN A VARIABLE REFRIGERANT FLOW (VRF) SYSTEM
    Hong, Sung Bin
    Yoo, Jin Woo
    Kim, Min Soo
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1040 - 1047
  • [3] EXERGY ANALYSIS OF THE PERFORMANCE OF A VARIABLE REFRIGERANT FLOW (VRF) AIR CONDITIONING SYSTEM
    Padilla, Miguel
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (01) : 57 - 68
  • [4] Development of an Optimal Start Control Strategy for a Variable Refrigerant Flow (VRF) System
    Lee, Yusung
    Kim, Woohyun
    ENERGIES, 2021, 14 (02)
  • [5] Comparison of exergy and thermoeconomic analysis for variable refrigerant flow (vrf) system with different rerigerants
    Atilgan, Ali Ibrahim
    Turkmen, Utku
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2017, 32 (02): : 343 - 353
  • [6] A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation
    Zhang, Rongpeng
    Sun, Kaiyu
    Hong, Tianzhen
    Yura, Yoshinori
    Hinokuma, Ryohei
    ENERGY AND BUILDINGS, 2018, 168 : 399 - 412
  • [7] Energy use analysis of the variable refrigerant flow (VRF) system versus the multi - split unit using TRNSYS
    Y. H. Yau
    M. ‘Amir
    Heat and Mass Transfer, 2020, 56 : 671 - 690
  • [8] Variable refrigerant flow technology
    Hwang, Yunho
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 903 - 903
  • [9] Full and Part Load Performance Evaluation of Variable Refrigerant Flow (VRF) System Using an Occupancy Simulated Research Building
    Im, Piljae
    Malhotra, Mini
    Munk, Jeffrey D.
    Lee, Jehyeon
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [10] Energy use analysis of the variable refrigerant flow (VRF) system versus the multi-split unit using TRNSYS
    Yau, Y. H.
    Amir, M.
    HEAT AND MASS TRANSFER, 2020, 56 (02) : 671 - 690