Investigation into the outlying swirl instability in the hydro-turbine draft tube under part-load operation

被引:4
|
作者
Muhirwa, Alexis [1 ]
Cai, Wei-Hua [1 ]
Li, Feng-Chen [2 ]
Su, Wen-Tao [1 ]
Binama, Maxime [1 ]
Li, Biao [1 ]
Li, Xiao-Bin [2 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Xidazhi St 92, Harbin 150001, Heilongjiang, Peoples R China
[2] Sun Yat Sen Univ, Sino French Inst Nucl Engn & Technol, Zhuhai, Peoples R China
基金
中国国家自然科学基金;
关键词
Draft tube; outlying domain; vortex rope; pressure pulsations; wall-mounted countermeasures; PRESSURE PULSATIONS; FRANCIS TURBINES; FLOW; FLUCTUATIONS; PUMP;
D O I
10.1177/0957650919889796
中图分类号
O414.1 [热力学];
学科分类号
摘要
The swirling trajectory of the draft tube flow improves the pressure recovery. Resultant flow instabilities are still problematic for an optimized hydropower generation. Engineering solutions are getting increasing importance. However; the depth of wall-mounted countermeasures is a challenging parameter. Performance assessment of countermeasures would rate dampened pressure pulsations in terms of their sources so as to place them at a proper location. A method for evaluating the instability in the outlying domain of the draft tube cone is herein suggested. Two part-load operating points with opposite polarity in pressure pulsations have been investigated. The numerical approach of Shear Stress Transport has been used, and experimental agreement of measurements for the pressure spectra is verified at the wall. Inlet flow conditions and the growth of the core instability are described. The outlying domain of the draft tube has been found to be composed of three distinct zones of influence: the shortest upper cone with upstream travelling influences, the longest middle cone with core excitation, and the lowermost cone dominated by the backward elbow influence. The wall response lies within a definite high-frequency range proper to the operating point. During admission, the frequency range becomes even wider due to high kinetic energy and the highest pressure amplitude of the draft tube is developed by the impact of blade passing frequency. The excitation from the vortex rope precession in the outlying domain strongly depends on the operating condition. Thus, further works should extend this study over a wider operation range, and mount pressure sensors on countermeasures in order to identify their own instability contribution.
引用
收藏
页码:139 / 153
页数:15
相关论文
共 50 条
  • [31] Experimental investigation of the performance of a reverse osmosis desalination unit under full- and part-load operation
    Dimitriou, Evangelos
    Mohamed, Essam Sh.
    Kyriakarakos, George
    Papadakis, George
    DESALINATION AND WATER TREATMENT, 2015, 53 (12) : 3170 - 3178
  • [32] Flow characteristics of a Francis turbine under deep part-load and various no-load conditions
    Hesari, Araz Rezavand
    Gauthier, Maxime
    Coulaud, Maxime
    Maciel, Yvan
    Houde, Sebastien
    EXPERIMENTS IN FLUIDS, 2024, 65 (11)
  • [33] Suppression of unsteady swirl flow in the draft tube of a Francis hydro turbine model using J-Groove
    Zhenmu Chen
    Patrick Mark Singh
    Young-Do Choi
    Journal of Mechanical Science and Technology, 2017, 31 : 5813 - 5820
  • [34] Suppression of unsteady swirl flow in the draft tube of a Francis hydro turbine model using J-Groove
    Chen, Zhenmu
    Singh, Patrick Mark
    Choi, Young-Do
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (12) : 5813 - 5820
  • [35] Combined air and water injection in Francis turbine draft tube at part load
    Kumar, Sandeep
    Gandhi, Bhupendra K.
    32ND IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2024, 1411
  • [36] STABILIZING THE CHARACTERISTICS OF A PUMP-TURBINE IN THE RANGE BETWEEN TURBINE PART-LOAD AND REVERSE PUMPING OPERATION.
    Klemm, Dieter
    Voith Research and Construction, 1982, 28 e : 1 - 2
  • [37] Power Quality Observations for Solar Photovoltaic Inverters under Part-load Operation
    Murray, Kevin
    McLorn, Gareth
    Morrow, John
    Best, Robert
    McLoone, Sean
    Liu, Amy
    2017 52ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2017,
  • [38] Thermoeconomic analysis of an intercooled, reheat, and recuperated gas turbine for cogeneration applications - Part II: Part-load operation
    Bhargava, R
    di Montenegro, GN
    Peretto, A
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 892 - 903
  • [39] CFD analysis of Part-Load operation of an Open-Circuit Induced-Draft cooling tower
    Castiglione, T.
    Nicoletti, F.
    Ferraro, V.
    Sangineto, C. M.
    APPLIED THERMAL ENGINEERING, 2023, 229
  • [40] Numerical Investigation of the Flow Structure in a Kaplan Draft Tube at Part Load
    Maddahian, R.
    Cervantes, M. J.
    Sotoudeh, N.
    28TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS (IAHR2016), PTS 1-12, 2016, 49