CFD analysis of Part-Load operation of an Open-Circuit Induced-Draft cooling tower

被引:7
|
作者
Castiglione, T. [1 ]
Nicoletti, F. [1 ]
Ferraro, V. [1 ]
Sangineto, C. M. [1 ]
机构
[1] Univ Calabria, Dept Mech Energy & Management Engn DIMEG, Cubo 46C, I-87036 Arcavacata Di Rende, CS, Italy
关键词
Induced draft cooling tower; Water Evaporation; CFD model; Partial load conditions; VALIDATION; SIMULATION; PARAMETER; MODEL; FLOW;
D O I
10.1016/j.applthermaleng.2023.120636
中图分类号
O414.1 [热力学];
学科分类号
摘要
Evaporative towers are the most widely used systems for cooling water in industrial processes. These systems, however, are characterized by high energy and water consumptions. Therefore, technologies and operating strategies for optimization of these devices are highly recommended. The heat exchange, which takes place inside an evaporative tower is very complex and not easy to model. In this work, an induced-draft evaporative tower is modelled by means of computational fluid dynamics (CFD), which is relatively new in this field of application. A numerical model, based on the adoption of sub-models for the heat exchange between the water droplets and humid air in the filling region, is developed and validated with experimental data, laying the foundation for further analysis in the future. The achieved results can be considered reliable and accurate as the numerical uncertainty is approximately 4 %. The study aims at evaluating and analyzing the thermo-fluid-dynamic quantities that characterize the heat exchange, with reference to water outlet temperature, cooling capacity, and evaporated water flow rate. In particular, partial load operation are analyzed. The conditions refer to the simultaneous reduction of water and air flow rates. The study shows that both at full load operation and by reducing water and air flow rates to 60 % of the design value while maintaining a constant water/air ratio, the tower process parameters are kept very close to the design ones. Under these conditions, the evaporated water is halved (-0.05 kg/s instead of -0.1 kg/s maintaining air flow at full load). Moreover, by adopting lower water and air flow rates a significant reduction of the electric power requested by the fan, from 15 kW at full load to about 8 kW at part load, is achieved.
引用
收藏
页数:13
相关论文
共 35 条
  • [1] THEORETICAL AND EXPERIMENTAL STUDY OF A CROSS-FLOW INDUCED-DRAFT COOLING TOWER
    Elazm, Mohamed Mahmoud Abo
    Elsafy, Ahmed Farouk
    THERMAL SCIENCE, 2009, 13 (04): : 91 - 98
  • [2] CFD MODELING ANALYSIS OF MECHANICAL DRAFT COOLING TOWER
    Lee, Si Y.
    Bollinger, James S.
    Garrett, Alfred J.
    Koffman, Larry D.
    HT2008: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2008, VOL 2, 2009, : 485 - 493
  • [3] A new theoretical method for predicating the part-load performance of natural draft dry cooling towers
    Ma, Huan
    Si, Fengqi
    Kong, Yu
    Zhu, Kangping
    Yan, Wensheng
    APPLIED THERMAL ENGINEERING, 2015, 91 : 1106 - 1115
  • [4] Investigation into the outlying swirl instability in the hydro-turbine draft tube under part-load operation
    Muhirwa, Alexis
    Cai, Wei-Hua
    Li, Feng-Chen
    Su, Wen-Tao
    Binama, Maxime
    Li, Biao
    Li, Xiao-Bin
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (01) : 139 - 153
  • [5] DYNAMIC MODELING AND EXPERIMENTAL ANALYSIS OF INDUCED DRAFT COOLING TOWER
    Languri, Ehsan M.
    Patil, Pallavi P.
    Cunningham, Glenn
    Welch, Albert
    Loftis, Anthony
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2016, 2016,
  • [6] Analysis and control of part-load unsteady flow in Francis turbine's draft tube
    Zhang, Ri-Kui
    Mao, Feng
    Wu, Jie-Zhi
    Chen, Shi-Yi
    Wu, Yu-Lin
    Liu, Shu-Hong
    PROCEEDINGS OF THE ASME TURBO EXPO 2007, VOL 6, PTS A AND B, 2007, : 1647 - 1658
  • [7] Generation of Twin Vortex Rope in the Draft-Tube Elbow of a Francis Turbine During Deep Part-Load Operation
    Khozaei, Mohammad Hossein
    Favrel, Arthur
    Masuko, Toshitake
    Yamaguchi, Naoki
    Miyagawa, Kazuyoshi
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (10):
  • [8] Thermoeconomic analysis of an intercooled, reheat, and recuperated gas turbine for cogeneration applications - Part II: Part-load operation
    Bhargava, R
    di Montenegro, GN
    Peretto, A
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2002, 124 (04): : 892 - 903
  • [9] Analytical model-based energy and exergy analysis of a gas microturbine at part-load operation
    Malinowski, Leszek
    Lewandowska, Monika
    APPLIED THERMAL ENGINEERING, 2013, 57 (1-2) : 125 - 132
  • [10] Performance analysis of induced draft cooling tower integrated with rotary silica gel mesh
    Sanjay
    Mishra, Sanjay
    Alam, Tabish
    HEAT TRANSFER, 2023, 52 (02) : 1275 - 1299