CFD analysis of Part-Load operation of an Open-Circuit Induced-Draft cooling tower

被引:7
|
作者
Castiglione, T. [1 ]
Nicoletti, F. [1 ]
Ferraro, V. [1 ]
Sangineto, C. M. [1 ]
机构
[1] Univ Calabria, Dept Mech Energy & Management Engn DIMEG, Cubo 46C, I-87036 Arcavacata Di Rende, CS, Italy
关键词
Induced draft cooling tower; Water Evaporation; CFD model; Partial load conditions; VALIDATION; SIMULATION; PARAMETER; MODEL; FLOW;
D O I
10.1016/j.applthermaleng.2023.120636
中图分类号
O414.1 [热力学];
学科分类号
摘要
Evaporative towers are the most widely used systems for cooling water in industrial processes. These systems, however, are characterized by high energy and water consumptions. Therefore, technologies and operating strategies for optimization of these devices are highly recommended. The heat exchange, which takes place inside an evaporative tower is very complex and not easy to model. In this work, an induced-draft evaporative tower is modelled by means of computational fluid dynamics (CFD), which is relatively new in this field of application. A numerical model, based on the adoption of sub-models for the heat exchange between the water droplets and humid air in the filling region, is developed and validated with experimental data, laying the foundation for further analysis in the future. The achieved results can be considered reliable and accurate as the numerical uncertainty is approximately 4 %. The study aims at evaluating and analyzing the thermo-fluid-dynamic quantities that characterize the heat exchange, with reference to water outlet temperature, cooling capacity, and evaporated water flow rate. In particular, partial load operation are analyzed. The conditions refer to the simultaneous reduction of water and air flow rates. The study shows that both at full load operation and by reducing water and air flow rates to 60 % of the design value while maintaining a constant water/air ratio, the tower process parameters are kept very close to the design ones. Under these conditions, the evaporated water is halved (-0.05 kg/s instead of -0.1 kg/s maintaining air flow at full load). Moreover, by adopting lower water and air flow rates a significant reduction of the electric power requested by the fan, from 15 kW at full load to about 8 kW at part load, is achieved.
引用
收藏
页数:13
相关论文
共 35 条
  • [31] Exergy analysis of off-design performance in solar-aided power generation systems: Evaluating the rationality of using part-load operation solution of coal-fired plants
    Huang, Guangqin
    Huang, Chang
    Liu, Han
    Huang, Huamao
    Shang, Wentao
    Wang, Weiliang
    ENERGY, 2024, 302
  • [32] Verification based on measurements and unsteady CFD analysis that low calculation load for 8 years: Pre-cooling / heating characteristics of the earth-to-air heat exchanger system in long-term operation (Part1)
    Muta A.
    Shiraishi Y.
    Tomoda K.
    Journal of Environmental Engineering (Japan), 2018, 83 (750): : 711 - 718
  • [33] Temperature field analysis and equal-amplitude temperature rise constraint current control method under open-circuit fault-tolerant operation for five-phase permanent magnet motor
    Jiang, Siyuan
    Gao, Mengzhen
    Niu, Junheng
    Feng, Haichao
    Ai, Liwang
    Xu, Xiaozhuo
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 202
  • [34] Capacity-loss diagnostic and life-time prediction in lithium-ion batteries: Part 1. Development of a capacity-loss diagnostic method based on open-circuit voltage analysis
    Wang, Tiansi
    Pei, Lei
    Wang, Tingting
    Lu, Rengui
    Zhu, Chunbo
    JOURNAL OF POWER SOURCES, 2016, 301 : 187 - 193
  • [35] PRE-COOLING / PRE-HEATING CHARACTERISTICS OF THE EARTH-TO-AIR HEAT EXCHANGER SYSTEM IN LONG-TERM OPERATION (PART 2): INVESTIGATION OF ACTUAL CONDITION OF AIR ENVIRONMENT IN UNDERGROUND AIR TUNNEL THROUGH FIELD MEASUREMENT AND CFD ANALYSIS IN SUMMER; [土壌熱交換システムの長期運用に伴う予冷・予熱特性(その2): 夏季実測調査とCFD 解析による地下ピット内空気環境の実態把握]
    Hirata K.
    Shiraishi Y.
    Tomoda K.
    Hasegawa K.
    Journal of Environmental Engineering (Japan), 2022, 87 (792): : 94 - 103