Hydroxyapatite-coated RM cup in primary hip arthroplasty

被引:12
|
作者
Ali, MS [1 ]
Kumar, A [1 ]
机构
[1] Corbett Hosp, Dept Orthopaed Surg, Stourbridge DY8 4JB, W Midlands, England
关键词
D O I
10.1007/s00264-002-0410-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed 113 patients with 127 primary total hip arthroplasties using a hydroxyapatite-coated RM (Robert Mathys) cup. Average patient age was 61 (30-70) years and mean follow-up was 9.4 (6-13) years. Four patients were lost to follow-up and nine patients died of unrelated causes during the course of the study. Three acetabular components were revised; two cups were radiologically loose and one was revised for marginal erosion. No radiolucency was noted in any of the three zones in the remaining cups. There were no cases of cup migration or dislocation. The life table method predicted a 10-year survival rate of 97.9% with revision of the acetabular component for any cause as the endpoint.
引用
收藏
页码:90 / 93
页数:4
相关论文
共 50 条
  • [41] Bone ingrowth on a smooth-surfaced hydroxyapatite-coated acetabular cup
    Y. Chung
    H. Kim
    K. Kim
    International Orthopaedics, 2002, 26 : 283 - 286
  • [42] Furlong Hydroxyapatite-Coated Hip Prosthesis vs the Charnley Cemented Hip Prosthesis
    Chandran, Prakash
    Azzabi, Mohamed
    Miles, Jeremy
    Andrews, Mark
    Bradley, John
    JOURNAL OF ARTHROPLASTY, 2010, 25 (01): : 52 - 57
  • [43] Hydroxyapatite-coated hip prostheses - Difficulties with revision in 4 cases
    Bhamra, MS
    Rao, GS
    Robson, MJ
    ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (01): : 49 - 52
  • [44] Hydroxyapatite-coated bipolar hemiarthroplasty for displaced intracapsular hip fracture
    Bradley, J
    Andrews, C
    Matteucci, P
    Burton, D
    Khalil, A
    Azzabi, M
    Cordosa, P
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S19 - S19
  • [45] THE HYDROXYAPATITE-COATED TOTAL HIP-REPLACEMENT III GENERATION OF HIP PROSTHESES
    MIKIC, S
    PFIRRMANN, RW
    ZENTRALBLATT FUR CHIRURGIE, 1990, 115 (11): : 695 - 705
  • [46] Bone scintigraphic appearance of asymptomatic hydroxyapatite-coated hip arthroplasties
    Moilanen, T
    Scott, G
    Newell, M
    Garvie, N
    Freeman, MAR
    JOURNAL OF ARTHROPLASTY, 1997, 12 (04): : 380 - 386
  • [47] EXPERIMENTAL AND CLINICAL-EXPERIENCE WITH HYDROXYAPATITE-COATED HIP IMPLANTS
    GEESINK, RGT
    ORTHOPEDICS, 1989, 12 (09) : 1239 - 1242
  • [48] Results of a Hydroxyapatite-Coated Modular Femoral Stem in Primary Total Hip Arthroplasty. A Minimum 5-Year Follow-Up
    Garcia-Rey, Eduardo
    Munoz, Teresa
    Montejo, Jorge
    Martinez, Javier
    JOURNAL OF ARTHROPLASTY, 2008, 23 (08): : 1132 - 1139
  • [49] Risk of subsidence and peri-prosthetic fractures using collared hydroxyapatite-coated stem for hip arthroplasty in the elderly
    Syed, Farhan
    Hussein, Amr
    Katam, Krishnaiah
    Saunders, Paul
    Young, Stephen K.
    Faisal, Mohammad
    HIP INTERNATIONAL, 2018, 28 (06) : 663 - 667
  • [50] Prospective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component
    Clauss, Martin
    Van der Straeten, Catherine
    Goossens, Marc
    HIP INTERNATIONAL, 2014, 24 (01) : 91 - 97