Hydroxyapatite-coated RM cup in primary hip arthroplasty

被引:12
|
作者
Ali, MS [1 ]
Kumar, A [1 ]
机构
[1] Corbett Hosp, Dept Orthopaed Surg, Stourbridge DY8 4JB, W Midlands, England
关键词
D O I
10.1007/s00264-002-0410-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed 113 patients with 127 primary total hip arthroplasties using a hydroxyapatite-coated RM (Robert Mathys) cup. Average patient age was 61 (30-70) years and mean follow-up was 9.4 (6-13) years. Four patients were lost to follow-up and nine patients died of unrelated causes during the course of the study. Three acetabular components were revised; two cups were radiologically loose and one was revised for marginal erosion. No radiolucency was noted in any of the three zones in the remaining cups. There were no cases of cup migration or dislocation. The life table method predicted a 10-year survival rate of 97.9% with revision of the acetabular component for any cause as the endpoint.
引用
收藏
页码:90 / 93
页数:4
相关论文
共 50 条
  • [21] Hydroxyapatite-coated femoral stems in primary total hip arthroplasty: A meta-analysis of randomized controlled trials
    Li, Shuzhen
    Huang, Baohua
    Chen, Yueping
    Gao, Hui
    Fan, Qie
    Zhao, Jinmin
    Su, Wei
    INTERNATIONAL JOURNAL OF SURGERY, 2013, 11 (06) : 477 - 482
  • [22] The effect of intramedullary bone plug on femoral stem migration of hydroxyapatite-coated hip arthroplasty
    Kligman, M
    Roffman, M
    ORTHOPEDICS, 2000, 23 (07) : 681 - 685
  • [23] Hip offset and leg-length restoration in revision hip arthroplasty with a monoblock, hydroxyapatite-coated stem
    Saunders, Paul
    Shaw, Debbie
    Sidharthan, Sijin
    Young, Stephen K.
    Board, Tim
    HIP INTERNATIONAL, 2023, 33 (05) : 880 - 888
  • [24] Survivorship and Radiological Analysis of a Monoblock, Hydroxyapatite-Coated Titanium Stem in Revision Hip Arthroplasty
    Saunders, Paul R. J.
    Shaw, Debbie A.
    Sidharthan, Sijin K.
    Siney, Paul D.
    Young, Stephen K.
    Board, Tim N.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06): : 1678 - 1685
  • [25] Analysis of retrieved hydroxyapatite-coated hip prostheses
    Gross, KA
    Walsh, W
    Swarts, E
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2004, 13 (02) : 190 - 199
  • [26] Analysis of retrieved hydroxyapatite-coated hip prostheses
    K. A. Gross
    W. Walsh
    E. Swarts
    Journal of Thermal Spray Technology, 2004, 13 : 190 - 199
  • [27] Clinical and radiological outcomes of total hip arthroplasty using a highly porous titanium cup or a conventional hydroxyapatite-coated titanium cup: A retrospective study in Japanese patients
    Tamaki, Yasuaki
    Goto, Tomohiro
    Takasago, Tomoya
    Wada, Keizo
    Hamada, Daisuke
    Sairyo, Koichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (01) : 163 - 168
  • [28] Migration and wear of a hydroxyapatite-coated hip prosthesis
    Onsten, I
    Carlsson, AS
    Sanzen, L
    Besjakov, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01): : 85 - 91
  • [29] Natural progress of a bone scan after cementless hydroxyapatite-coated total hip arthroplasty
    Suh, KT
    Lee, CB
    Kim, IJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (389) : 134 - 142
  • [30] Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty
    Cho, Jin-Ho
    Garino, Jonathan P.
    Choo, Suk-Kyu
    Han, Kye-Young
    Kim, Jung-Hoon
    Oh, Hyoung-Keun
    CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (04) : 214 - 220