Hydroxyapatite-coated RM cup in primary hip arthroplasty

被引:12
|
作者
Ali, MS [1 ]
Kumar, A [1 ]
机构
[1] Corbett Hosp, Dept Orthopaed Surg, Stourbridge DY8 4JB, W Midlands, England
关键词
D O I
10.1007/s00264-002-0410-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed 113 patients with 127 primary total hip arthroplasties using a hydroxyapatite-coated RM (Robert Mathys) cup. Average patient age was 61 (30-70) years and mean follow-up was 9.4 (6-13) years. Four patients were lost to follow-up and nine patients died of unrelated causes during the course of the study. Three acetabular components were revised; two cups were radiologically loose and one was revised for marginal erosion. No radiolucency was noted in any of the three zones in the remaining cups. There were no cases of cup migration or dislocation. The life table method predicted a 10-year survival rate of 97.9% with revision of the acetabular component for any cause as the endpoint.
引用
收藏
页码:90 / 93
页数:4
相关论文
共 50 条
  • [31] Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
    Hiroshi Imai
    Joji Miyawaki
    Tomomi Kamada
    Akira Maruishi
    Jun Takeba
    Hiromasa Miura
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 611 - 618
  • [32] Total hip arthroplasty using hydroxyapatite-coated cementless cup for rapidly destructive coxarthrosis: Minimum 10-year follow-up
    Sonohata, Motoki
    Nakashima, Takema
    Kitajima, Masaru
    Kawano, Shunsuke
    Eto, Shuichi
    Mawatari, Masaaki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2021, 26 (02) : 225 - 229
  • [33] Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
    Imai, Hiroshi
    Miyawaki, Joji
    Kamada, Tomomi
    Maruishi, Akira
    Takeba, Jun
    Miura, Hiromasa
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (03): : 611 - 618
  • [34] RADIOGRAPHIC PATTERNS IN TOTAL HIP-ARTHROPLASTY - HYDROXYAPATITE-COATED AND UNCOATED FEMORAL STEM PROSTHESES
    FOX, MG
    RAK, KM
    LISECKI, EJ
    CASTELLO, PH
    RADIOLOGY, 1995, 197 : 396 - 396
  • [35] RETRIEVAL ANALYSIS OF A HYDROXYAPATITE-COATED HIP-PROSTHESIS
    BLOEBAUM, RD
    MERRELL, M
    GUSTKE, K
    SIMMONS, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (267) : 97 - 102
  • [36] Comparison of a highly porous titanium cup (Tritanium) and a conventional hydroxyapatite-coated porous titanium cup: A retrospective analysis of clinical and radiological outcomes in hip arthroplasty among Japanese patients
    Yoshioka, Shinji
    Nakano, Shunji
    Kinoshita, Yutaka
    Nakamura, Masaru
    Goto, Tomohiro
    Hamada, Daisuke
    Sairyo, Koichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (06) : 967 - 972
  • [37] Uncemented hydroxyapatite- coated stems for primary total hip arthroplasty
    Markel, David C.
    Gheraibeh, Petra J.
    CURRENT ORTHOPAEDIC PRACTICE, 2008, 19 (02): : 119 - 123
  • [38] Bone ingrowth on a smooth-surfaced hydroxyapatite-coated acetabular cup
    Chung, YY
    Kim, HD
    Kim, KS
    INTERNATIONAL ORTHOPAEDICS, 2002, 26 (05) : 283 - 286
  • [39] Fully hydroxyapatite-coated collared femoral stems in direct anterior versus direct lateral hip arthroplasty
    Heaven, Sebastian
    Perelgut, Maxwell
    Vasarhelyi, Edward
    Howard, James
    Teeter, Matthew
    Lanting, Brent
    CANADIAN JOURNAL OF SURGERY, 2021, 64 (02) : E205 - E210
  • [40] Migration and wear of hydroxyapatite-coated press-fit cups in revision hip arthroplasty -: A radiostereometric study
    Nivbrant, B
    Kärrholm, J
    JOURNAL OF ARTHROPLASTY, 1997, 12 (08): : 904 - 912