Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients
被引:10
|作者:
Shammi, Ummul Afia
[1
]
D'Alessandro, Michelle Felicia
[2
]
Altes, Talissa
[3
]
Hersman, F. William
[4
]
Ruset, Iulian C.
[5
]
Mugler, John, III
[6
,7
]
Meyer, Craig
[6
,7
]
Mata, Jamie
[6
]
Qing, Kun
[6
]
Thomen, Robert
[1
,3
]
机构:
[1] Univ Missouri, Biomed Biol & Chem Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Sch Med, Columbia, MO USA
[3] Univ Missouri, Sch Med, Radiol, Columbia, MO 65211 USA
[4] Univ New Hampshire, Phys, Durham, NH 03824 USA
[5] Xemed LLC, Durham, NH USA
[6] Univ Virginia, Sch Med, Radiol & Med Imaging, Charlottesville, VA 22908 USA
[7] Univ Virginia, Biomed Engn, Charlottesville, VA USA
关键词:
Hyperpolarized MRI;
Ventilation defect percentage;
Cystic fibrosis;
Lung defects;
MRI scan;
MAGNETIC-RESONANCE;
HEALTHY-VOLUNTEERS;
QUANTITATIVE-ANALYSIS;
LUNG-DISEASE;
CHILDREN;
ASTHMA;
TOLERABILITY;
SAFETY;
D O I:
10.1016/j.acra.2021.01.007
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: In this study, we compared hyperpolarized He-3 and Xe-129 images from patients with cystic fibrosis using two commonly applied magnetic resonance sequences, standard gradient echo (GRE) and balanced steady-state free precession (TrueFISP) to quantify regional similarities and differences in signal distribution and defect analysis. Materials and Methods: Ten patients (7M/3F) with cystic fibrosis underwent hyperpolarized gas MR imaging with both He-3 and Xe-129. Six had MRI with both GRE, and TrueFISP sequences and four patients had only GRE seuence but not TrueFISP. Ventilation defect percentages (VDPs) were calculated as lung voxels with <60% of the whole-lung hyperpolarized gas signal mean and was measured in all datasets. The voxel signal distributions of both Xe-129 and He-3 gases were visualized and compared using violin plots. VDPs of hyperpolarized He-3 and Xe-129 were compared in Bland-Altman plots; Pearson correlation coefficients were used to evaluate the relationships between inter-gas and inter-scan to assess the reproducibility. Results: A significant correlation was demonstrated between Xe-129 VDP and He-3 VDP for both GRE and TrueFISP sequences (rho = 0.78, rho<0.0004). The correlation between the GRE and TrueFISP VDP for He-3 was rho = 0.98 and was rho = 0.91 for Xe-129. Overall, Xe-129 (27.2 +/- 9.4) VDP was higher than He-3 (24.3 +/- 6.9) VDP on average on cystic fibrosis patients. Conclusion: In patients with cystic fibrosis, the selection of hyperpolarized Xe-129 or He-3 gas is most likely inconsequential when it comes to measure the overall lung function by VDP although Xe-129 may be more sensitive to starker lung defects, particularly when using a TrueFISP sequence.